首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
地震区城镇建筑框架结构概念设计   总被引:1,自引:0,他引:1  
自从唐山大地震以来,我国地震专家及其科技人员通过长期分析研究地震所造成的危害,对地震的经验不断总结,对地震的破坏规律有了更深刻的认识,提出了“概念设计”的设计理念,要使结构具有良好的抗震性能和足够的抗震能力,“概念设计”比“结构设计”更为重要。主要通过对钢筋混凝土框架结构震害的统计分析,阐述了抗震“概念设讣”的有关问题。通过建筑场地选择、地基基础的设计、结构体系及结构构件的抗震设计等方面的分析,明确了“概念设计”的原则和要求,特别是针对工程实际中的钢筋混凝土结构的延性设计问题,总结了延性设计的要点及其实现方法,从而消除了建筑中的薄弱环节,提高了房屋结构的整体抗震性能。  相似文献   

2.
This paper describes a new seismic protection system for timber platform frame buildings, either for new construction or retrofit. The system consists in connecting the timber frame to a steel structure that includes hysteretic energy dissipators designed to absorb most of the seismic input energy thus protecting the timber frame and the other steel members; alternatively, the system might use other types of dissipative devices. The steel structure consists of four steel stacks (located at each of the four façades) and steel collectors embracing each slab; the stacks and the collectors are connected, at each floor level, through the energy dissipators. The steel structure is self‐supporting, that is, the timber frame is not affected by horizontal actions and can be designed without accounting for any seismic provision; in turn, the steel members do not participate in the main load‐carrying system. The timber‐steel interface is designed to avoid any stress concentration in the transfer of horizontal forces and to guarantee that the yielding of the dissipators occurs prior to any timber failure. The energy dissipation capacity of the suggested system is discussed, and an application example on a six‐story timber building is presented; this case corresponds to highly demanding conditions because of the relatively large building height and weight, the high local seismicity, and the soft soil condition. This research belongs to a wider project aiming to promote the structural use of timber by improving the seismic capacity of wooden buildings; this research includes experiments and advanced numerical simulation. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
This paper presents a new concept for enhancing the seismic ductility and damping capacity of diagrid structural frames by using shear-link fuse devices and its seismic performance is assessed through nonlinear static and dynamic analysis.The architectural elegancy of the diagrid structure attributed to its triangular leaning member configuration and high structural redundancy make this system a desirable choice for tall building design.However,forming a stable energy dissipation mechanism in diagrid framing remains to be investigated to expand its use in regions with high seismicity.To address this issue,a diagrid framing design is proposed here which provides a competitive design option in highly seismic regions through its increased ductility and improved energy dissipation capacity provided by replaceable shear links interconnecting the diagonal members at their ends.The structural characteristics and seismic behavior(capacity,stiffness,energy dissipation,ductility) of the diagrid structural frame are demonstrated with a 21-story building diagrid frame subjected to nonlinear static and dynamic analysis.The findings from the nonlinear time history analysis verify that satisfactory seismic performance can be achieved by the proposed diagrid frame subjected to design basis earthquakes in California.In particular,one appealing feature of the proposed diagrid building is its reduced residual displacement after strong earthquakes.  相似文献   

4.
耗能梁段作为偏心支撑结构的耗能元件,在大震作用下通过弹塑性变形吸收地震能量,保护主体结构处于弹性受力状态。现行规范基于强度的设计理论,为了保证耗能梁段进入塑性或破坏,梁柱构件需要进行放大内力设计,导致截面过大,而且基于强度的设计方法很难保证结构的整体破坏状态。目前,抗震设计越来越重视基于性能的设计思想,该方法能够评估结构的弹塑性反应。对于高强钢组合偏心支撑,其中耗能梁段和支撑采用Q345钢,框架梁柱采用Q460或者Q690高强度钢材,高强钢不仅带来良好的经济效益,而且能够推广高强钢在抗震设防区的应用。利用基于性能设计方法设计了4种不同形式的高强钢组合偏心支撑钢框架,包括K形、Y形、V形和D形,考虑4层、8层、12层和16层的影响。通过Pushover分析和非线性时程分析评估该结构的抗震性能,研究结果表明:4种形式的高强钢组合偏心支撑钢框架具有类似的抗震性能,在罕遇地震作用下,几乎所有耗能梁段均参与耗能,而且层间侧移与耗能梁段转角沿高度分布较为均匀。其中:D形偏心支撑具有最大的抗侧刚度,但延性较差,而Y形偏心支撑的抗侧刚度最弱,但延性最佳。  相似文献   

5.
Post‐tensioned technologies for concrete seismic resistant buildings were first developed in the 1990s during the PREcast Seismic Structural Systems program. Among different solutions, the hybrid system proved to be the most resilient solution providing a combination of re‐centering and energy dissipative contributions respectively by using post‐tensioned tendons and mild steel reinforcement. The system, while providing significant strength and energy dissipation, reduces structural element damage and limits post‐earthquake residual displacements. More recently, the technology was extended to laminated veneer lumber (LVL) structural members, and extensive experimental and numerical work was carried out and allowed the development of reliable analytical and numerical models as well as design guidelines. On the basis of the experimental and numerical outcomes, this paper presents the evaluation of the seismic performance factors for post‐tensioned rocking LVL walls using the FEMA P‐695 procedure. Several archetype buildings were designed considering different parameters such as the building and story height, the type of seismic resistant system, the magnitude of gravity loads and the seismic design category. Lumped plasticity models were developed for each index archetype to simulate the behavioral aspects and collapse mechanisms. Non‐linear quasi‐static analyses were carried out to evaluate the system over‐strength factor; moreover, non‐linear time history analyses were performed using the incremental dynamic analysis concept to assess the collapse of each building. From the results of quasi‐static and dynamic analyses the response modification factor, R, system over‐strength factor, Ω0, and deflection amplification factor, Cd, values of, respectively, 7, 3.5 and 7.5 are recommended. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
Fragility curves are generally developed using a single parameter to relate the level of shaking to the expected structural damage. The main goal of this work is to use several parameters to characterize the earthquake ground motion. The fragility curves will, therefore, become surfaces when the ground motion is represented by two parameters. To this end, the roles of various strong‐motion parameters on the induced damage in the structure are compared through nonlinear time‐history numerical calculations. A robust structural model that can be used to perform numerous nonlinear dynamic calculations, with an acceptable cost, is adopted. The developed model is based on the use of structural elements with concentrated nonlinear damage mechanics and plasticity‐type behavior. The relations between numerous ground‐motion parameters, characterizing different aspects of the shaking, and the computed damage are analyzed and discussed. Natural and synthetic accelerograms were chosen/computed based on a consideration of the magnitude‐distance ranges of design earthquakes. A complete methodology for building fragility surfaces based on the damage calculation through nonlinear numerical analysis of multi‐degree‐of‐freedom systems is proposed. The fragility surfaces are built to represent the probability that a given damage level is reached (or exceeded) for any given level of ground motion characterized by the two chosen parameters. The results show that an increase from one to two ground‐motion parameters leads to a significant reduction in the scatter in the fragility analysis and allows the uncertainties related to the effect of the second ground‐motion parameter to be accounted for within risk assessments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
为提高斜交网格结构的抗震性能,提出一种双防线可恢复性能斜交网格结构。双防线可恢复性能斜交网格结构采用剪切耗能段和特定梁端塑形铰进行集中耗能,使主体结构构件保持弹性。剪切耗能段不承受和传递重力荷载,易在震后修复或更换,使建筑可迅速恢复功能。为实现目标耗能机制,对等效能量塑形设计法进行改进以适用于可恢复性能斜交网格结构,并进行结构设计举例。采用OpenSees软件对所设计结构建立详细的有限元计算模型,进行非线性动力时程分析,以验证双防线耗能机制并评估抗震性能。分析结果表明:(1)小震、中震和大震下的结构顶部位移角分别为0.28%、0.8%和1.7%,与性能设计目标基本相同;(2)中震时剪切耗能段屈服,特定梁端未出现塑性铰;(3)大震时,特定梁端出现塑性铰以增加结构耗能能力,剪切耗能段屈服且处于延性范围内。因此新型可恢复性能斜交网格结构具有有效的双防线耗能机制,在中震后可迅速修复,在大震中可保持延性,实现"中震可修,大震不倒"的性能目标。  相似文献   

8.
Controlled rocking steel frames have been proposed as an efficient way to avoid the structural damage and residual deformations that are expected in conventional seismic force resisting systems. Although the base rocking response is intended to limit the force demands, higher mode effects can amplify member design forces, reducing the viability of the system. This paper suggests that seismic forces may be limited more effectively by providing multiple force‐limiting mechanisms. Two techniques are proposed: detailing one or more rocking joints above the base rocking joint and providing a self‐centring energy dissipative (SCED) brace at one or more levels. These concepts are applied to the design of an eight‐storey prototype structure and a shake table model at 30% scale. A simple numerical model that was used as a design tool is in good agreement with frequency characterization and low‐amplitude seismic tests of the shake table model, particularly when multiple force‐limiting mechanisms are active. These results suggest that the proposed mechanisms can enable better capacity design by reducing the variability of peak seismic force demands without causing excessive displacements. Similar results are expected for other systems that rely on a single location of concentrated nonlinearity to limit peak seismic loads. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Current seismic design codes and damage estimation tools neglect the influence of successive events on structures. However, recent earthquakes have demonstrated that structures damaged during an initial event (mainshock) are more vulnerable to severe damage and collapse during a subsequent event (aftershock). This increased vulnerability to damage translates to increased likelihood of loss of use, property, and life. Thus, a reliable risk assessment tool is required that characterizes the risk of the undamaged structure subjected to an initial event and the risk of the damaged structure under subsequent events. In this paper, a framework for development of aftershock fragilities is presented; these aftershock fragilities define the likelihood that a building damaged during a mainshock will exhibit a given damage state following one or more aftershocks. Thus, the framework provides a method for characterizing the risk associated with damage accumulation in the structure. The framework includes the following: (i) creation of a numerical model of the structure; (ii) characterization of building damage states; (iii) generation of a suite of mainshock–aftershocks; (iv) mainshock–aftershock analyses; and (v) development of aftershock fragility curves using probabilistic aftershock demand models, defined as a linear regression of aftershock demand–intensity pairs in a logarithmic space, and damage‐state prediction models. The framework is not limited to a specific structure type but requires numerical models defining structural response and linking structural response with damage. In the current study, non‐ductile RC frames (low‐rise, mid‐rise, and high‐rise) are selected as case studies for the application of the framework. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
The use of energy dissipation systems for the seismic control of steel structures represents a valid alternative to conventional seismic design methods. The seismic devices currently employed are mostly based on the metallic yielding technology due to the large feasibility and efficiency they can provide. Within this context, in the current paper an innovative solution based on the adoption of low‐yield‐strength pure aluminium shear panels (SPs) for seismic protection of steel moment‐resisting frames is proposed and investigated. In order to prove the effectiveness of the system, a wide numerical study based on both static and dynamic non‐linear analyses has been carried out, considering a number of different frame‐to‐shear panel combinations, aiming at assessing the effect of the main influential parameters on the seismic response of the structure. The obtained results show that the contribution provided by aluminium SPs is rather significant, allowing a remarkable improvement of the seismic performance of the structure in terms of stiffness, strength and ductility, with the possibility to strongly limit the damage occurring in the members of moment‐resisting frames. In particular, it is clearly emphasized that the stiffening effect provided by SPs allows a more rational design procedure to be adopted, since the serviceability limit state check does not lead to unavoidable and uneconomical increase of the size of main structural members. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
Confined masonry (CM) is a typical building technique in Latin American countries. This technique, due to its simplicity of construction and similarity with traditional practices of reinforced concrete building, presents a potential of use in European regions with moderate-to-high seismicity. However, most of the procedures for seismic design in codes for Latin America are force-based, which appears to be inadequate due to the high dissipative response observed for CM. This paper presents a simplified numerical-analytical approach to model CM structures using pushover analysis, aiming to apply performance-based design procedures. First, a data mining process is performed on a database of experimental results collected from lateral tests on CM walls to adjust prediction models for the wall shear strength and to determine the input relevance through a sensitivity analysis. Then, an analytical model of CM structures for pushover analysis is proposed with basis on a wide-column approach that employs an adaptive shear load-displacement constitutive relation. The proposed method is compared with a discrete element model that represents explicitly the confinements-masonry interaction, against the experimental results obtained in a quasi-static test of a full-scale tridimensional CM structure. The accuracy of the predictions from both methods is very satisfactory, allowing to capture the base shear-displacement envelope and also the damage patterns of the structure, thus, demonstrating the ability of the methods to be used in performance-based seismic assessment and design of CM buildings.  相似文献   

12.
目前我国房屋建筑抗震采用的以小震弹性计算为基础的设计方法,使工程师忽视了对建筑结构在强烈地震作用下破坏模式的充分考虑与设计,使得建筑结构的大震安全性有时难以得到保证。"破坏-安全"抗震理念,以房屋建筑最重要的抗震安全性能为目标,要求设计人员对结构的预期破坏模式有充分的把握和控制,使结构在强烈地震作用下能够形成明确的预期破坏模式并具备一定的耗能能力,从而以经济的代价保证结构其余部分在强烈地震作用下的安全。本文结合我国汶川地震灾后恢复重建与加固改造的实际情况,介绍了"破坏-安全"抗震理念及其设计概念,并介绍了国内外研究人员与工程师在实现"破坏-安全"抗震理念方面所提出的创新抗震结构体系及其研究成果。希望"破坏-安全"这一抗震理念及其相关技术能够在我国广大的经济欠发达地区的抗震设计实践中得到推广,以全面提高我国经济欠发达地区房屋建筑的抗震安全性。  相似文献   

13.
Conventional design methodology for the earthquake‐resistant structures is based on the concept of ensuring ‘no collapse’ during the most severe earthquake event. This methodology does not envisage the possibility of continuous damage accumulation during several not‐so‐severe earthquake events, as may be the case in the areas of moderate to high seismicity, particularly when it is economically infeasible to carry out repairs after damaging events. As a result, the structure may collapse or may necessitate large scale repairs much before the design life of the structure is over. This study considers the use of design force ratio (DFR) spectrum for taking an informed decision on the extent to which yield strength levels should be raised to avoid such a scenario. DFR spectrum gives the ratios by which the yield strength levels of single‐degree‐of‐freedom oscillators of different initial periods should be increased in order to limit the total damage caused by all earthquake events during the lifetime to a specified level. The DFR spectra are compared for three different seismicity models in case of elasto‐plastic oscillators: one corresponding to the exponential distribution for return periods of large events and the other two corresponding to the lognormal and Weibull distributions. It is shown through numerical study for a hypothetical seismic region that the use of simple exponential model may be acceptable only for small values of the seismic gap length. For moderately large to large seismic gap lengths, it may be conservative to use the lognormal model, while the Weibull model may be assumed for very large seismic gap lengths. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

14.
A multi‐objective optimization procedure is presented for designing steel moment resisting frame buildings within a performance‐based seismic design framework. Life cycle costs are considered by treating the initial material costs and lifetime seismic damage costs as two separate objectives. Practical design/construction complexity, important but difficult to be included in initial cost analysis, is taken into due account by a proposed diversity index as another objective. Structural members are selected from a database of commercially available wide flange steel sections. Current seismic design criteria (AISC‐LRFD seismic provisions and 1997 NEHRP provisions) are used to check the validity of any design alternative. Seismic performance, in terms of the maximum inter‐storey drift ratio, of a code‐verified design is evaluated using an equivalent single‐degree‐of‐freedom system obtained through a static pushover analysis of the original multi‐degree‐of‐freedom frame building. A simple genetic algorithm code is used to find a Pareto optimal design set. A numerical example of designing a five‐storey perimeter steel frame building is provided using the proposed procedure. It is found that a wide range of valid design alternatives exists, from which a decision maker selects the one that balances different objectives in the most preferred way. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

15.
Within the last decades, simplified methods alternative to dynamic nonlinear analysis have been developed to estimate the seismic performance of structures toward a performance‐oriented design. Considering drift as the main parameter correlated with structural damage, its estimation is of main importance to assess the structural performance. While traditional force‐based design deals with calibrated force reduction factors based on the expected structural ductility, other methods are based on the definition of a viscous damping factor defined as a function of the expected energy dissipated by the structure. An example is the capacity spectrum method. This method can be applied even without any a priori calibration or designer arbitrariness. This allows considering several peculiarities of the seismic behavior of precast structures, which may be influenced by nontraditional hysteresis of connections and members, interaction with the cladding panels, Pδ effects, etc. The paper aims at verifying the soundness and accuracy of this method through the comparison of its predictions against the results of cyclic and pseudodynamic tests on precast structures, including single‐ and multistory buildings either stiff or flexible, obtained on full‐scale building prototypes tested within the framework of recent research projects (namely, “Precast Structures EC8,” “Safecast,” and “Safecladding”). Two simple methodologies of determination of the equivalent viscous damping from a force‐displacement cycle, based on the dissipated energy in relation to 2 different estimates of the elastic strain energy, are addressed and compared. Comments on the possible use of this procedure for the estimation of the seismic performance of precast structures are provided.  相似文献   

16.
A design procedure for seismic retrofitting of concentrically and eccentrically braced frame buildings is proposed and validated in this paper. Rocking walls are added to the existing system to ensure an almost uniform distribution of the interstorey displacement in elevation. To achieve direct and efficient control over the seismic performance, the design procedure is founded on the displacement‐based approach and makes use of overdamped elastic response spectra. The top displacement capacity of the building is evaluated based on a rigid lateral deformed configuration of the structure and on the ductility capacity of the dissipative members of the braced frames. The equivalent viscous damping ratio of the braced structure with rocking walls is calculated based on semi‐empirical relationships specifically calibrated in this paper for concentrically and eccentrically braced frames. If the equivalent viscous damping ratio of the structure is lower than the required equivalent viscous damping ratio, viscous dampers are added and arranged between the rocking walls and adjacent reaction columns. The design internal forces of the rocking walls are evaluated considering the contributions of more than one mode of vibration. The proposed design procedure is applied to a large set of archetype braced frame buildings and its effectiveness verified by nonlinear dynamic analysis.  相似文献   

17.
A new seismic design manner, namely building mass damper (BMD), which is inspired from a combination of mid‐story isolation and tuned mass damper design concepts, recently attracts immense attention. It is mainly because that the use of partial structural mass of the building as an energy absorber in the BMD design can overcome the drawback of limited response reduction due to insufficient added tuned mass in the conventional tuned mass damper design. In this study, an optimum BMD (OBMD) design approach, namely optimum dynamic characteristic control approach, based on a simplified 3‐lumped‐mass structure model is proposed to seismically protect both the superstructure (or tuned mass) and the substructure (or primary structure), respectively, above and below the control layer. A series of sensitivity analyses and experimental studies on different parameters, including mass, frequency, and damping ratios, of a building model designed with a BMD system were conducted. The test results verify the practical feasibility of the BMD concept as well as the effectiveness of the proposed OBMD design. Furthermore, by comparing with the numerical results of a mid‐story isolated counterpart, it is demonstrated that the proposed OBMD design can have a comparable and even better control performance.  相似文献   

18.
This paper presents the development, experimental testing, and numerical modelling of a new hybrid timber‐steel moment‐resisting connection that is designed to improve the seismic performance of mid‐rise heavy timber moment‐resisting frames (MRF). The connection detail incorporates specially designed replaceable steel links fastened to timber beams and columns using self‐tapping screws. Performance of the connection is verified through experimental testing of four 2/3 scale beam‐column connections. All 4 connection specimens met the acceptance criteria specified in the AISC 341‐10 provisions for steel moment frames and exhibit high strength, ductility, and energy dissipation capacity up to storey drifts exceeding 4%. All of the timber members and self‐tapping screw connections achieved their design objective, remaining entirely elastic throughout all tests and avoiding brittle modes of failure. To assess the global seismic performance of the newly developed connection in a mid‐rise building, a hybrid timber‐steel building using the proposed moment‐resisting connection is designed and modelled in OpenSees. To compare the seismic performance of the hybrid MRF with a conventional steel MRF, a prototype steel‐only building is also designed and modelled in OpenSees. The building models are subject to a suite of ground motions at design basis earthquake and maximum credible earthquake hazard levels using non‐linear time history analysis. Analytical results show that drifts and accelerations of the hybrid building are similar to a conventional steel building while the foundation forces are significantly reduced for the hybrid structure because of its lower seismic weight. The results of the experimental program and numerical analysis demonstrate the seismic performance of the proposed connection and the ability of the hybrid building to achieve comparable seismic performance to a conventional steel MRF.  相似文献   

19.
The use of collision shear walls (bumper‐type), acting transversely to the side subject to pounding, as a measure to minimize damage of reinforced concrete buildings in contact, is investigated using 5‐story building models. The buildings were designed according to the Greek anti‐seismic and reinforced concrete design codes. Owing to story height differences potential pounding in case of an earthquake will occur between floor slabs, a case specifically chosen because this is when pounding can turn out to be catastrophic. The investigation is carried out using nonlinear dynamic analyses for a real earthquake motion and also a simplified solution for a triangular dynamic force of short duration, comparable to the forces caused by pounding. For such analyses, nonlinear, prismatic beam–column elements are used and the effects of pounding are expressed in terms of changes in rotational ductility factors of the building elements. The local effects of pounding on the collision shear walls are investigated using a detailed nonlinear finite element model of the shear walls and results are expressed in terms of induced stresses. It is found that pounding will cause instantaneous acceleration pulses in the colliding buildings and will somewhat increase ductility demands in the members of the top floor, but all within tolerable limits. At the same time the collision walls will suffer repairable local damage at the points of contact, but will effectively protect both buildings from collapse, which could occur if columns were in the place of the walls. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
针对超限高层建筑结构抗震设计,提出了基于性能设计方法的性能目标,通过结构在小震、中震、大震作用下的弹性、弹塑性静力和动力时程分析,对三水准地震作用下结构构件进行了承载力定量分析。从理论上证明了结构性能可以达到“小震不坏,中震可修,大震不倒”的抗震设防目标,同时进行了1:20模型的结构振动台试验,确证了实际结构设计的安全性。  相似文献   