1.
Assessment of seismic design response factors of concrete wall buildings   总被引:3,自引:2,他引:1  
To verify the seismic design response factors of high-rise buildings, five reference structures, varying in height from 20- to 60-stories, were selected and designed according to modern design codes to represent a wide range of concrete wall structures. Verified fiber-based analytical models for inelastic simulation were developed, considering the geometric nonlinearity and material inelasticity of the structural members. The ground motion uncertainty was accounted for by employing 20 earthquake records representing two seismic scenarios, consistent with the latest understanding of the tectonic setting and seismicity of the selected reference region (UAE). A large number of Inelastic Pushover Analyses (IPAs) and Incremental Dynamic Collapse Analyses (IDCAs) were deployed for the reference structures to estimate the seismic design response factors. It is concluded that the factors adopted by the design code are adequately conservative. The results of this systematic assessment of seismic design response factors apply to a wide variety of contemporary concrete wall buildings with various characteristics.  相似文献   

2.
摩擦阻尼器是一种构造简单的耗能减振装置,已应用于国内外多座新建建筑的抗震设计和已建建筑的抗震加固.半主动磨擦阻尼器则通过调整阻尼器的起滑力来改善被动摩擦阻尼器的耗能减振性能。本文研究了被动及半主动摩擦阻尼器对于高耸塔架结构地震反应的减振效果。为满足摩擦阻尼器对高耸塔架结构风振控制的特殊需要,本文建立了合肥电视塔的空间桁架有限元模型和串联多自由度体系模型,并在形成控制力变换矩阵和计算摩擦阻尼器两端的相对位移的过程中综合地运用了这两种力学模型。在半主动摩擦阻尼器的控制策略方面,本文提出了一种基于次优控制理论的半主动控制策略.本文研究表明,摩擦阻尼器可以抑制高耸塔架结构的地震反应.而半主动摩擦阻尼辞的耗能减振效果明显优于被动摩擦阻尼器.  相似文献   

3.
磁流变阻尼器作为一种比较典型的半主动控制元件,具有构造简单、响应速度快、耐久性好、阻尼力大且连续可调等优点。即使地震中能源中断,磁流变阻尼器仍可以作为被动耗能装置继续工作发挥作用,可靠性高。设计合理有效的磁流变阻尼器半主动控制方法,对于整体结构的减震效果尤其重要。提出一种改进的磁流变阻尼器的半主动控制策略-改进的Bang-Bang控制策略,对装有磁流变阻尼器的减震控制3层框架结构进行了一系列的实时混合模拟试验,对多种半主动控制方法下的振动控制效果进行试验分析。试验结果表明:磁流变阻尼器对框架结构的减震效果显著,并验证了提出的磁流变阻尼器半主动控制策略的有效性。  相似文献   

4.
This paper presents an experimental investigation on semi-active seismic response control of a multistory building with a podium structure using multiple magnetorheological (MR) dampers manipulated by a logic control algorithm. The experiments are performed in three phases on a seismic simulator with a slender 12-story building model representing a multi-story building and a relatively stiff 3-story building model typifying a podium structure. The first phase of the investigation is to assess control performance of using three MR dampers to link the 3-story building to the 12-story building, in which seismic responses of the controlled two buildings are compared with those of the two buildings without any connection and with rigid connection. The second phase is to investigate reliability of the semi-active control system and robustness of the logic control algorithm when 2 out of 3 MR dampers fail and when the electricity supply to MR dampers is completely stopped. The last phase is to examine sensitivity of semi-active control performance of two buildings to change in ground excitation. The experimental results show that multiple MR dampers with the logic control algorithm can achieve a significant reduction in seismic responses of both buildings. The proposed semi-active control system is of high reliability and good robustness.  相似文献   

5.
A comparative analytical study of several control strategies for semi-active(SA) devices installed in baseisolated buildings aiming to reduce earthquake induced vibrations is presented.Three force tracking schemes comprising a linear controller plus a "clipped" algorithm and a nonlinear output feedback controller(NOFC) are considered to tackle this problem.Linear controllers include the integral controller(I),the linear quadratic regulator(LQR) and the model predictive controller(MPC).A single degree-of-freedom system subjected to input accelerograms representative of the Portuguese seismic actions are first used to validate and evaluate the feasibility of these strategies.The obtained results show that structural systems using SA devices can in general outperform those equipped with passive devices for lower fundamental frequency structural systems,namely base-isolated buildings.The effectiveness of the proposed strategies is also evaluated on a 10 storey base-isolated dual frame-wall building.The force tracking scheme with an integral controller outperforms the other three as well as the original structure and the structure equipped with passive devices.  相似文献   

6.
An online hybrid test was carried out on a 40-story 120-m high concrete shear wall structure. The structure was divided into two substructures whereby a physical model of the bottom three stories was tested in the laboratory and the upper 37 stories were simulated numerically using ABAQUS. An overlapping domain method was employed for the bottom three stories to ensure the validity of the boundary conditions of the superstructure. Mixed control was adopted in the test. Displacement control was used to apply the horizontal displacement, while two controlled force actuators were applied to simulate the overturning moment, which is very large and cannot be ignored in the substructure hybrid test of high-rise buildings. A series of tests with earthquake sources of sequentially increasing intensities were carried out. The test results indicate that the proposed hybrid test method is a solution to reproduce the seismic response of high-rise concrete shear wall buildings. The seismic performance of the tested precast high-rise building satisfies the requirements of the Chinese seismic design code.  相似文献   

7.
神经网络半主动TLCD对偏心结构的减震控制   总被引:5,自引:0,他引:5  
本文采用在结构水平双向设置TLCD半主动控制装置的方法,对偏心结构在多维地震作用下的振动控制问题进行研究。首先利用多层前向神经网络,对偏心结构在双向地震输入下的两个平动方向的反应进行预测,然后在建立起半主动控制策略的基础上,利用神经网络根据控制准则调整TLCD的开孔率,实现以结构的半主动控制,数值结构表明,这种方法能对结构的平动反应和扭转反应都能起到的较好的减震效果。  相似文献   

8.
基于AFSMC算法的结构非线性振动MR控制与仿真分析   总被引:2,自引:0,他引:2  
作为最近发展起来的高性能半主动控制装置,磁流变阻尼器通过改变磁场强度来调节控制力,可靠度高,体积小,出力大,并且具有Fail-Safe的特点,是一种具有广泛应用前景的新型结构控制装置。本文主要研究结构非线性振动的磁流变阻尼半主动控制。首先采用我们提出的自适应模糊滑模控制(AFSMC)算法得到了结构非线性振动的主动控制力,然后参照主动控制力,提出和仿真实现了结构非线性振动的磁流变阻尼半主动控制。最后,针对3层和20层benchm ark非线性模型,每层均设置一个磁流变阻尼器,对在给定的地震动下的结构响应进行了计算,分析了半主动控制跟踪主动控制的效果,并且对于半主动控制下的结构位移响应、加速度响应等各项指标也进行了对比分析。仿真结果表明,由于自适应模糊滑模控制算法与半主动控制算法相结合可以很好地实现结构非线性振动的半主动控制,所以能够得到令人满意的控制结果。  相似文献   

9.
采用WSR模型分析建筑工程抗震结构造价控制问题时,存在造价控制效果差的弊端。通过设计的高层建筑工程抗震结构造价控制模型构建造价控制的递阶层次结构,获取高层建筑工程造价控制的多种方案,从多种方案中通过三标度法和权重向量法获取造价控制的最优方案;另外采用质量量化QoS调度方法进行高层建筑工程造价效益控制约束均衡设计,以获取最优方案中高层建筑工程抗震结构造价控制的结果。实验结果表明,所设计模型可有效分析高层建筑的质量化特征,可改进控制高层抗震结构工程造价,预估消耗成本可控制在1.8万元以下,且分析耗时均值为0.15 h,具有节省成本和效率快的优势,控制效果较好。  相似文献   

10.
相邻结构地震反应MR阻尼器控制的仿真分析   总被引:2,自引:0,他引:2  
本文仿真分析了应用磁流变(MR)阻尼器对相邻结构地震反应的控制效果,为进一步开展模型试验研究奠定了基础。建立了地震激励下相邻结构MR阻尼器控制系统的运动方程,提出了描述MR阻尼器阻尼力滞回特性的改进S igmoid模型,分别对应用开关控制、半主动控制以及最小或最大电流被动控制的四种控制方法的相邻结构地震反应的控制效果进行了仿真分析。结果表明,在相邻结构间连接安装MR阻尼器可以有效地控制相邻结构的地震反应,且开关控制方法和半主动控制方法的控制效果均好于两种被动控制方法,体现了MR阻尼器阻尼力可调的优点;在四种控制方法中,半主动控制方法的控制效果最好,体现了MR阻尼器阻尼力具有连续调节能力的优点;若能解决MR阻尼器的剩磁问题,半主动控制方法的控制效果会得到进一步的提高。  相似文献   

11.
传统高层建筑地震损伤模型不能反映构件极限滞回耗能随累积幅值的改变情况,无法有效确定组合参数,离散性较大。为此,设计一种远场长周期地震下高层建筑的地震损伤模型。针对不同层次高层建筑结构,依据广义力-广义变形曲线,构建变形损伤模型。结合累积能量比、远场长周期地震瞬时输入能比构建能量损伤模型。从变形与能量两方面综合评价损伤,依据钢筋混凝土结构构建最大反应变形与耗损能量的线性组合地震损伤模型,并对其进行改进。实验选用ILA003、ILA048和TCU115三种长周期地震波,计算不同构件和高层建筑结构整体损伤结果,验证所提模型的可靠性。将所提模型应用于实际高层建筑中,发现其实用性强。  相似文献   

12.
Human perception to tremors during earthquakes in high-rise buildings is usually associated with psychological discomfort such as fear and anxiety. This paper presents a methodology for estimating the level of perception to tremors for occupants living in high-rise buildings subjected to ground motion excitations. Unlike other approaches based on empirical or historical data, the proposed methodology performs a regression analysis using the analytical results of two generic models of 15 and 30 stories. The recorded ground motions in Singapore are collected and modified for structural response analyses. Simple predictive models are then developed to estimate the perception level to tremors based on a proposed ground motion intensity parameter—the average response spectrum intensity in the period range between 0.1 and 2.0 s. These models can be used to predict the percentage of occupants in high-rise buildings who may perceive the tremors at a given ground motion intensity. Furthermore, the models are validated with two recent tremor events reportedly felt in Singapore. It is found that the estimated results match reasonably well with the reports in the local newspapers and from the authorities. The proposed methodology is applicable to urban regions where people living in high-rise buildings might feel tremors during earthquakes.  相似文献   

13.
王娟 《地震工程学报》2018,40(3):413-420
为了提高高层建筑壁板结构的抗震性,需设计高层建筑在连续振动下的壁板结构失稳定BIM模型。应用软件:通过Revit塑造高层建筑模型和结构模型,结合SAP2000建模性能塑造高层建筑结构的有限元实体模型,实现高层建筑模型的转换,设计BIM模型的IFOD软件总体结构,实现BIM模型的智能化管理。参数:在BIM模型的基础上,分析了连续振动下高层建筑壁板结构风致响应,给出高层建筑壁板结构的平均风响应、脉动风响应,得出高层建筑壁板结构位移,实现了高层建筑在连续振动下的壁板结构稳定性分析。实验:实验结果说明,所设计BIM模型可对连续振动下的高层建筑加速度时程以及位移时程进行准确分析,且相比传统方法,本文方法对高层建筑在连续振动下的壁板结构是否失稳判断结果比较准确。  相似文献   

14.
应用MBC策略的MRD 隔震结构半主动控制   总被引:2,自引:0,他引:2  
磁流变阻尼器(Magnetorheological Damper,MRD)与隔震垫组成的半主动隔震系统能有效地改善被动隔震系统的性能,消除隔震层因过大变形产生的不利影响。基于市场机制的控制(Market-Based Control,MBC)策略是一种利用自由经济市场来模拟控制系统,用销售商和消费者来代替能量源系统和受控系统,并应用市场中商品的供需规律来完成系统控制能量的分配,实现对受控系统有效控制的策略。本文将MBC策略应用于此种半主动隔震系统,提出了相应的控制策略,实现对MRD电压的实时有效控制。算例分析表明,采用此策略能充分利用MRD的变阻尼特性,使结构振动控制效果显著。  相似文献   

15.
A semi-active tuned mass damper (TMD) which is capable of adjusting initial displacement and damping is applied to seismic protection of structures. Control algorithms are derived in closed forms using perturbation analysis on modal properties of the single degree of freedom (SDOF) structure/TMD system. Because perturbation solutions are given in a relatively simple form, the control algorithms are developed in a physically intuitive manner. In the first half of the paper, the control algorithms are introduced using numerical simulations of the impulse response. Then the algorithms are applied to seismic protection of civil structures using the strategy of multiple releasing and capturing of TMDs. The control strategy for seismic control is summarized in a flow chart. Numerical studies with the El Centro earthquake record show that the proposed semi-active method has higher performance than conventional passive TMDs.  相似文献   

16.
高层隔震结构非线性地震响应分析及设计方法研究   总被引:3,自引:0,他引:3  
高层隔震结构的分析理论和设计方法是目前隔震技术向高层建筑推广的2个关键理论问题。本文以高烈度区宿迁市已经竣工的高层隔震建筑阳光大厦为工程实例,对高层隔震结构的非线性地震响应分析方法进行了研究,包括隔震支座竖向不同拉压刚度的模拟、各种类型的隔震支座水平力学特性的准确模拟,以及不同地震动输入方式和输入角度对隔震支座受拉情况的影响分析等;在此基础上,对隔震层的设计方法进行了分析,提出了隔震层设计的基本原则,进而给出了控制隔震层设计的基本指标,包括隔震支座的长期面压、极值面压、隔震层偏心率等;最后,对高层隔震结构的相关构造要求进行了必要的说明。  相似文献   

17.
张立维 《地震工程学报》2019,41(6):1637-1642
高层建筑物在地震作用下易出现倒塌状况,严重影响人身安全,因此高层建筑物地震安全防护距离的预测至关重要。设计以基础数据库为核心的高层建筑物地震安全防护距离预测系统,通过高层建筑物基本信息系统采集高层建筑物高度、宽度、结构类型等基本数据信息,并将这些信息存储到震害数据库系统中;地震危害模型分析系统依据数据库系统中存储的这些建筑物基本信息,分析地震危险性后,通过研究地震时高层建筑上部结构水平、底部及顶部先接触地面三种落地状态情况下,计算得到薄弱层和薄弱层上部结构高度的安全防护距离。实验验证在人工地震波作用下,利用该预测系统可有效获取实验小区高层建筑物的安全防护距离界定示意图,且其能够准确分析地震作用下高层建筑物晃动时"飞石"安全距离,以及三种地震波作用下建筑物地震安全防护距离分布规律和主要影响范围,其预测效果好。  相似文献   

18.
针对目前隔震体系尚不能减小竖向地震反应的缺陷,提出并研制了采用碟形弹簧的竖向半主动隔震装置。竖向半主动隔震装置是由碟形弹簧和外套油缸组成的,且由电磁阀控制油缸内油体与外接蓄油箱内油体间的油路,可实现竖向半主动隔震控制,提出了竖向隔震控制的半主动策略,结合水平隔震支座可实现三维隔震。通过振动台地震模拟实验,验证了三维隔震体系的效能,该研究对高烈度地区隔震技术的改善具有应用参考价值。  相似文献   

19.
The seismic events occurred in recent years highlighted the extreme vulnerability of large part of the existing constructed facilities and the need to adopt innovative solutions to improve their seismic performance. With this purpose, the possible exploitation of a seismic early warning system (SEWS) in the framework of semi-active structural control using magnetorheological (MR) dampers is herein investigated. The main idea consists in the use of these time-varying properties devices to control an hosting structure by changing their behaviour according to an anticipate estimate, provided by the SEWS, of the peak ground acceleration (PGA) of the incoming earthquake. In this way, the dampers are able to adapt their mechanical characteristics to the specific earthquake obtaining the optimal seismic response. The present paper describes the application of this protection technique to a case-study problem, a highway bridge located in Southern California. The seismic response of the benchmark bridge is investigated by nonlinear time-history analyses by adopting 16 real earthquake ground excitations. These accelerograms cover a wide variety of magnitudes, distances to fault and soil types. Possible errors on estimation of PGA provided by SEWS and their effects on the proposed control system are also considered. The results obtained confirm that unavoidable errors in the PGA estimates provided by the SEWS do not propagate to the seismic response. Conversely, the proposed strategy turns out to damp these errors, resulting in a robust seismic behaviour of the protected structure.  相似文献   

20.
为了研究新型电磁惯性质量阻尼器(Electromagnetic Inertial Mass Damper,EIMD)应用于偏心高层结构振动控制工程的可行性,鉴于半主动控制技术的优点,基于LQR主动控制算法,提出一种可行的EIMD-偏心高层结构半主动控制策略,同时研究EIMD在结构每层中安装位置不同对于控制偏心高层结构扭转反应的影响。以一个实体24层偏心高层结构作为研究对象验证地震作用下所提控制策略的有效性,仿真结果表明:(1)所提半主动控制策略基本能够达到主动控制对于结构振动反应分量的控制效果;(2)当采用半主动控制策略时,调整EIMD的安装位置对于偏心高层结构转角和转角加速度反应有着较好的控制效果。  相似文献   