首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper proposes a hybrid control strategy combining passive and semi‐active control systems for seismic protection of cable‐stayed bridges. The efficacy of this control strategy is verified by examining the ASCE first‐generation benchmark problem for a seismically excited cable‐stayed bridge, which employs a three‐dimensional linearized evaluation bridge model as a testbed structure. Herein, conventional lead–rubber bearings are introduced as base isolation devices, and semi‐active dampers (e.g., variable orifice damper, controllable fluid damper, etc.) are considered as supplemental damping devices. For the semi‐active dampers, a clipped‐optimal control algorithm, shown to perform well in previous studies involving controllable dampers, is considered. Because the semi‐active damper is a controllable energy‐dissipation device that cannot add mechanical energy to the structural system, the proposed hybrid control strategy is fail‐safe in that the bounded‐input, bounded‐output stability of the controlled structure is guaranteed. Numerical simulation results show that the performance of the proposed hybrid control strategy is quite effective in protecting seismically excited cable‐stayed bridges. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

2.
Sliding base‐isolation systems used in bridges reduce pier drifts, but at the expense of increased bearing displacements under near‐source pulse‐type earthquakes. It is common practice to incorporate supplemental passive non‐linear dampers into the isolation system to counter increased bearing displacements. Non‐linear passive dampers can certainly reduce bearing displacements, but only with increased isolation level forces and pier drifts. The semi‐active controllable non‐linear dampers, which can vary damping in real time, can reduce bearing displacements without further increase in forces and pier drifts; and hence deserve investigation. In this study performance of such a ‘smart’ sliding isolation system, used in a 1:20 scaled bridge model, employing semi‐active controllable magneto‐rheological (MR) dampers is investigated, analytically and experimentally, under several near‐fault earthquakes. A non‐linear analytical model, which incorporates the non‐linearities of sliding bearings and the MR damper, is developed. A Lyapunov control algorithm for control of the MR damper is developed and implemented in shake table tests. Analytical and shake table test results are compared. It is shown that the smart MR damper reduces bearing displacements further than the passive low‐ and high‐damping cases, while maintaining isolation level forces less than the passive high‐damping case. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

3.
大底盘多塔楼结构的混合隔震控制   总被引:2,自引:0,他引:2  
结合某实际工程,针对大底盘多塔楼结构提出混合隔震的控制策略,即对大底盘上的一栋或多栋塔楼采用隔震技术,并在隔震层附设一定数量的被动、主动或半主动的减震控制装置。建立了这种大底盘多塔楼结构混合隔震控制体系的运动方程,方程中各塔楼与下部结构及隔震层之间的刚度解耦,并考虑了隔震层的非线性。研究中比较了被动非线性粘滞阻尼器,半主动变孔隙阻尼器与理想主动控制时的减震控制效果。结果表明,这种混合隔震体系可以有效地减小上部塔楼与下部结构的地震反应,提高大底盘多塔楼结构的抗震安全性,取得明显的经济和社会效益。半主动变孔隙阻尼器可以极好地追踪理想主动控制力,取得与理想主动控制相近的减震控制效果。被动非线性粘滞阻尼器也能取得较好的减震效果,且易于维护,经济性较好,从工程应用的角度来看更为现实可行,具有较好的应用推广价值。  相似文献   

4.
The primary purpose of this research is to improve the seismic response of a complex asymmetric tall structure using viscoelastic(VE) dampers. Asymmetric structures have detrimental effects on the seismic performance because such structures create abrupt changes in the stiffness or strength that may lead to undesirable stress concentrations at weak locations. Structural control devices are one of the effective ways to reduce seismic impacts, particularly in asymmetric structures. For passive vibration control of structures, VE dampers are considered among the most preferred devices for energy dissipation. Therefore, in this research, VE dampers are implemented at strategic locations in a realistic case study structure to increase the level of distributed damping without occupying significant architectural space and reducing earthquake vibrations in terms of story displacements(drifts) and other design forces. It has been concluded that the seismic response of the considered structure retrofitted with supplemental VE dampers corresponded well in controlling the displacement demands. Moreover, it has been demonstrated that seismic response in terms of interstory drifts was effectively mitigated with supplemental damping when added up to a certain level. Exceeding the supplemental damping from this level did not contribute to additional mitigation of the seismic response of the considered structure. In addition, it was found that the supplemental damping increased the total acceleration of the considered structure at all floor levels, which indicates that for irregular tall structures of this type, VE dampers were only a good retrofitting measure for earthquake induced interstory deformations and their use may not be suitable for acceleration sensitive structures. Overall, the research findings demonstrate how seismic hazards to these types of structures can be reduced by introducing additional damping into the structure.  相似文献   

5.
A semi-active tuned mass damper (TMD) which is capable of adjusting initial displacement and damping is applied to seismic protection of structures. Control algorithms are derived in closed forms using perturbation analysis on modal properties of the single degree of freedom (SDOF) structure/TMD system. Because perturbation solutions are given in a relatively simple form, the control algorithms are developed in a physically intuitive manner. In the first half of the paper, the control algorithms are introduced using numerical simulations of the impulse response. Then the algorithms are applied to seismic protection of civil structures using the strategy of multiple releasing and capturing of TMDs. The control strategy for seismic control is summarized in a flow chart. Numerical studies with the El Centro earthquake record show that the proposed semi-active method has higher performance than conventional passive TMDs.  相似文献   

6.
Adaptive base-isolation of civil structures using variable amplification   总被引:1,自引:0,他引:1  
Semi-active dampers are used in base-isolation to reduce the seismic response of civil engineering structures. In the present study, a new semi-active damping system using variable amplification will be investigated for adaptive baseisolation. It uses a novel variable amplification device (VAD) connected in series with a passive damper. The VAD is capable of producing multiple amplification factors, each corresponding to a different amplification state. Forces from the damper are amplified to the structure according to the current amplification state, which is selected via a semi-active control algorithm specifically tailored to the system's tmique damping characteristics. To demonstrate the effectiveness of the VAD-damper system for adaptive base-isolation, numerical simulations are conducted for three and seven-story base-isolated buildings subject to both far and near-field ground motions. The results indicate that the system can achieve significant reductions in response compared to the base-isolated buildings with no damper. The proposed system is also found to perform well compared to a typical semi-active damper.  相似文献   

7.
相邻结构地震反应MR阻尼器控制的仿真分析   总被引:2,自引:0,他引:2  
本文仿真分析了应用磁流变(MR)阻尼器对相邻结构地震反应的控制效果,为进一步开展模型试验研究奠定了基础。建立了地震激励下相邻结构MR阻尼器控制系统的运动方程,提出了描述MR阻尼器阻尼力滞回特性的改进S igmoid模型,分别对应用开关控制、半主动控制以及最小或最大电流被动控制的四种控制方法的相邻结构地震反应的控制效果进行了仿真分析。结果表明,在相邻结构间连接安装MR阻尼器可以有效地控制相邻结构的地震反应,且开关控制方法和半主动控制方法的控制效果均好于两种被动控制方法,体现了MR阻尼器阻尼力可调的优点;在四种控制方法中,半主动控制方法的控制效果最好,体现了MR阻尼器阻尼力具有连续调节能力的优点;若能解决MR阻尼器的剩磁问题,半主动控制方法的控制效果会得到进一步的提高。  相似文献   

8.
针对巨-子结构隔震体系,在隔震层处或子结构顶部与主结构连接处,施加SMA-压电智能复合阻尼器,从而形成巨-子结构智能隔震体系。本文通过限界Hrovat最优控制算法设计了巨-子结构智能隔震体系的半主动控制器,在此基础上,对巨-子结构智能隔震体系进行了Simulink控制效果仿真分析,同时比较了控制装置安装位置的不同对结构控制效果的影响,并与普通隔震结构的减震效果进行了对比。研究结果表明,智能隔震控制1(隔震层加控制装置)和智能隔震控制2(子结构顶部加控制装置)2种控制方案在控制结构的位移方面效果相差不大。总体而言,智能隔震控制2对于控制子结构单元顶部的绝对加速度效果更为显著,但是相对于普通隔震而言,特别是在控制隔震层位移方面2种方案都具有较好的控制效果。实施智能控制可以有效改善巨-子结构被动控制体系的抗震性能,并能降低隔震结构在遭受强震时由于隔震层出现过大位移导致结构倾覆的危险。  相似文献   

9.
Two linear optimal control laws and a non-linear control strategy are critically evaluated. They are implemented in a ten-story frame structure. For the linear control laws, both an active bracing system and a hybrid mass damper are considered as control devices, while the non-linear control law can be implemented with either an active or semi-active bracing system. The active and semi-active systems are compared to a passive bracing system with linear viscous dampers and to a hybrid system consisting of a passive bracing and a hybrid mass damper. Dimensionless indices based on the reduction of the maximum story drift and on the maximum control force required are introduced to compare the efficiencies of different control strategies. While the linear optimal control laws exhibit an excellent performance, the non-linear control law, in addition to its simplicity and robustness, appears to be more efficient when the allowable control force is within a certain limit. Furthermore, one attractive feature of the latter is that it can be implemented with semi-active devices to minimize the power requirement.  相似文献   

10.
摩擦阻尼器是一种构造简单的耗能减振装置,已应用于国内外多座新建建筑的抗震设计和已建建筑的抗震加固.半主动磨擦阻尼器则通过调整阻尼器的起滑力来改善被动摩擦阻尼器的耗能减振性能。本文研究了被动及半主动摩擦阻尼器对于高耸塔架结构地震反应的减振效果。为满足摩擦阻尼器对高耸塔架结构风振控制的特殊需要,本文建立了合肥电视塔的空间桁架有限元模型和串联多自由度体系模型,并在形成控制力变换矩阵和计算摩擦阻尼器两端的相对位移的过程中综合地运用了这两种力学模型。在半主动摩擦阻尼器的控制策略方面,本文提出了一种基于次优控制理论的半主动控制策略.本文研究表明,摩擦阻尼器可以抑制高耸塔架结构的地震反应.而半主动摩擦阻尼辞的耗能减振效果明显优于被动摩擦阻尼器.  相似文献   

11.
This paper presents experimental and analytical results on the seismic response of a rigid structure supported on isolation systems that consist of either lead rubber or sliding bearings. Shake table tests are conducted with various levels of isolation damping that is provided from the bearings and supplemental viscous fluid dampers. The table motions originated from recorded strong ground motions that have been compressed to the extent that the mass of the model structure corresponds to the mass of a typical freeway overcrossing. Experimental data are used to validate mechanical idealizations and numerical procedures. The study concludes that supplemental damping is most effective in suppressing displacements of rigid structures with moderately long isolation periods (TI≤3 sec) without affecting base shears. Friction damping is most effective in suppressing displacement amplifications triggered by long duration pulses—in particular, pulses that have duration close to the isolation period. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

12.
Theoretical and practical issues concerning the multi-faceted task of mitigating the latero-torsional seismic response of a prototypal frame structure with asymmetric mass distribution are approached.Chevron braces with embedded magnetorheological dampers acting on the interstory drift are used to ensure additional energy dissipation.The semi-active control strategy employed to govern the modifi cation of the damper characteristics via feedback is based on the selection of optimal forces according to a H2/L...  相似文献   

13.
Abstrect The recent developments of theoretical research, model tests and engineering applications of structural control in mainland China are reviewed in this paper. It includes seismic isolation, passive energy dissipation, active and semi-active control, smart materials and smart structural systems. It can be seen that passive control methods, such as seismic isolation and energy dissipation methods, have developed into the mature stage in China. At the same time, great progress has been made in active and semi-active control, and smart actuators or smart dampers and smart structural systems. Finally, some future research initiatives for structural control in civil engineering are suggested. Supported by : National Natural Science Foundation of China (Grant No. 50025821)  相似文献   

14.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
基于AFSMC算法的结构非线性振动MR控制与仿真分析   总被引:2,自引:0,他引:2  
作为最近发展起来的高性能半主动控制装置,磁流变阻尼器通过改变磁场强度来调节控制力,可靠度高,体积小,出力大,并且具有Fail-Safe的特点,是一种具有广泛应用前景的新型结构控制装置。本文主要研究结构非线性振动的磁流变阻尼半主动控制。首先采用我们提出的自适应模糊滑模控制(AFSMC)算法得到了结构非线性振动的主动控制力,然后参照主动控制力,提出和仿真实现了结构非线性振动的磁流变阻尼半主动控制。最后,针对3层和20层benchm ark非线性模型,每层均设置一个磁流变阻尼器,对在给定的地震动下的结构响应进行了计算,分析了半主动控制跟踪主动控制的效果,并且对于半主动控制下的结构位移响应、加速度响应等各项指标也进行了对比分析。仿真结果表明,由于自适应模糊滑模控制算法与半主动控制算法相结合可以很好地实现结构非线性振动的半主动控制,所以能够得到令人满意的控制结果。  相似文献   

16.
The concept of the hybrid passive control system is studied analytically by investigating the seismic response of steel frame structures. Hybrid control systems consist of two different passive elements combined into a single device or system. The hybrid systems investigated in this research consist of a rate‐dependent damping device paired with a rate‐independent energy dissipation element. The innovative configurations exploit individual element strengths and offset their weaknesses through multiphased behavior. A nine‐story, five‐bay steel moment‐frame was used for the analysis. Six different seismic resisting systems were analyzed and compared. The conventional systems included a special moment‐resisting frame (SMRF) and a dual SMRF–buckling‐restrained brace (BRB) system. The final four configurations are hybrid passive systems. The different hybrid configurations utilize a BRB and either a high‐damping rubber damper or viscous fluid damper. The analyses were run in the form of an incremental dynamic analysis. Several damage measures were calculated, including maximum roof drift, base shear, and total roof acceleration. The results demonstrate the capability of hybrid passive control systems to improve structural response compared with conventional lateral systems and to be effective for performance‐based seismic design. Each hybrid configuration improved some aspect of structural response with some providing benefits for multiple damage measures. The multiphased nature provides improved response for frequent and severe seismic events. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
This paper describes shaking table tests of a multi-storey scale-model building structure subjected to seismic excitation and controlled by a semi-active fluid damper control system. The semi-active dampers were installed in the lateral bracing of the structure and the mechanical properties of the dampers were modified according to control algorithms which utilized the measured response of the structure. A simplified time-delay compensation method was developed to account for delays within the control system. The results of the shaking table tests are presented and interpreted and analytical predictions are shown to compare reasonably well with the experimental results. © 1997 John Wiley & Sons, Ltd.  相似文献   

18.
磁流变智能基础隔震系统研究   总被引:5,自引:3,他引:2  
本文将磁流变(MR)阻尼器与普通橡胶隔震支座相结合,组成智能基础隔震系统应用到结构控制中。在详细介绍了系统的各部分与整体运行情况后,采用LQR经典线性最优控制算法对结构进行了振动台试验研究。试验结果表明,由MR阻尼器提供可调阻尼力的智能隔震控制系统,能有效克服被动隔震最优控制频带窄的缺点,对较宽频域范围地震激励能进行有效的振动控制。其相对一般被动隔震装置,能同时减小上部结构加速度和隔震层位移.  相似文献   

19.
基于双线性和三线性的力-位移滞回线假设,导出了钢梁阻尼器隔震系统等效阻尼比与阻尼器延性率的关系;为了获得大阻尼比隔震系统,以尽量减小隔震系统的地震反应,求得了使系统阻尼比为最大的阻尼器相应延性率(即最佳延性率)所需满足的条件;给出了在给定地震地面运动输入条件下,使系统阻尼器变形位移达到最佳延性率的阻尼器初始刚度和屈服位移的确定方法。  相似文献   

20.
提出一种组合型减震结构,由钢框架、节点阻尼器和原结构连接组成,外附钢框架将节点阻尼器连接在原混凝土框架结构上形成的增设节点阻尼器的外附钢框架结构,节点阻尼器的剪切滞回变形可以减小结构自身需要消耗的能量,从而提高原结构抗震性能。对原混凝土结构和增设节点阻尼器的组合型结构进行了的振动台试验。通过分析结构在不同地震波激励下的加速度和位移响应,得出楼层加速度和层位移的减震效果。研究结果表明:该结构体系在小震作用下通过提高结构刚度来增强其抗震性能;在大震作用下则可借助节点阻尼器的变形耗能来提升结构耗能能力,结构加速度减震系数达到53%,层间位移减震系数高达72%,验证了增设节点阻尼器的外附钢框架结构的减震效果。  相似文献   