首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 109 毫秒
1.
轴向压力对配筋砌体短肢剪力墙抗剪性能的影响   总被引:1,自引:0,他引:1  
通过对6片足尺290mm厚全灌芯配筋砌块砌体短肢剪力墙拟静力试验结果的分析,利用非线性有限元方法,模拟了此种墙体在压弯剪共同作用下的抗剪特性,研究了轴向压力对配筋砌块砌体短肢剪力墙抗剪性能的影响。研究表明,在不同高宽比的墙体中,轴向压力均对墙体的抗剪能力有较大影响,随着轴向压力增大,墙体抗剪能力先增大后减小(轴压比n从0.1增长到0.4时,墙体抗剪能力逐渐增大,而n从0.4增长到0.6时,墙体抗剪能力却逐渐减小);随着轴向压力的增大,墙体延性在逐渐减小。提出当轴压比等于0.3时,墙体抗剪能力和延性均较好,建议在建筑抗震设计规范中采用此值。  相似文献   

2.
针对泥质砂岩黏土附加导电还没有综合定量评价指标的现状,从Archie公式和Waxman-Smits方程计算的含水饱和度的相对误差出发定义了黏土附加导电强度指数η,并考察了地层水电导率Cw、阳离子交换容量Qv、含水饱和度Sw、饱和度指数nη的影响,给出了黏土附加导电强度判别方法和图版,通过低阻油气层的工程应用实例探讨了η在饱和度方程选取中的应用.结果表明,ηCwSwn值的增大而以近似乘幂规律减小,随Qv的增大而近似线性增大;CwQvη的影响最大,nSw次之;无法由单一因素判断黏土附加导电性强弱,必须综合考虑QvCwSwn的影响;对于低阻油气层,可利用该指数按照"三步法"及判别图版定量判断低阻成因并为饱和度模型的选取提供技术依据.  相似文献   

3.
通过2个带窗洞配筋砌块砌体剪力墙试件的拟静力试验,研究带窗洞配筋砌块砌体剪力墙的破坏形态、承载能力、变形能力等抗震性能以及墙体两端构造柱的影响。试验结果表明:试件为洞口两侧墙肢剪切破坏,洞口以下墙体有斜裂缝,但裂缝宽度不大;相对于无构造柱的试件,墙体两端设置构造柱的试件的水平力-位移滞回曲线略为饱满,名义屈服水平力和峰值水平力分别提高了约30%和20%,刚度退化较为缓慢;2个试件的极限位移角相同,均为1/90,满足大震作用下剪力墙结构的变形能力要求。  相似文献   

4.
党鹏飞    夏松林    刘启方 《世界地震工程》2021,(3):200-206
地震工程学中高频衰减参数κ是一个重要的参数。距离为0 km处的参数κ0在地震动模拟中最常用,其主要控制傅里叶谱在高频部分的衰减特征。计算了日本熊本地区矩震级Mw为5.0~7.1级且震中距小于250 km的81个台站水平方向的κVs30(距离地表30 m深度的平均剪切波速)。在不同矩震级和不同场地距离下,用线性拟合和二次拟合统计了κVs30的关系,并与全球平均水平进行了比较。结果表明:κVs30呈很强的负相关性,相关性随矩震级的增大而增大,且熊本地区的κ要高于全球平均水平。矩震级较小时,二次拟合的效果好于线性拟合,建议用二次拟合的经验关系式进行κVs30的估计。近场情况下,κ总体要小于远场,线性拟合与二次拟合的效果差异不大。对C类场地,拟合的κ与全球平均水平较接近。对B类场地,拟合的κ高于全球平均水平。远场情况下,二次拟合的效果好于线性拟合,但对B类和C类场地,κ均小于全球平均水平。本文的研究结果既能在随机模拟方法中结合场地的地壳放大使用来达到提高模拟精度的目的,又能为只有钻孔信息的地区提供κ的估计。  相似文献   

5.
王鹏  郑建常 《地震》2013,33(1):111-118
讨论了华北地区中强地震前地震力标度的时空变化特征, 首先介绍了地震力标度的物理意义, 给出了由传统经验公式推导出的地震力标度σ值的计算方法, σ值是一个表征地震时震源处断层平均驱动力的物理量, 基于地震波能量推导得到, 介于地震频度和能量之间, 根据经典通用的经验公式, 地震力标度σ值与震级ML存在lgσ=1.14ML+6.22标度关系; 结合华北地区(34°~42°N ; 110°~124°E; )地震活动的特点, 利用1980年以来2500多次3级以上地震, 研究了MS≥5.0中强震前σ值的变化规律, 结果发现该指标能客观反映地震活动的增强与平静。 中强地震前存在σ值高值异常, σ值有由低转高, 在高值点发震的特征。 空间上σ值的分布与地质构造、 地震带和强震孕育过程有关, 中强震前地震力标度σ值有成片增加的过程, 对中强地震预测有一定的指导意义。  相似文献   

6.
三层单排配筋剪力墙结构抗震性能试验研究   总被引:2,自引:0,他引:2  
为了对双排配筋剪力墙和单排配筋剪力墙的抗震性能进行对比研究,本文设计了1个1/3缩尺的三层混凝土剪力墙结构模型,模型的一侧墙体为双向双排配筋,另一侧墙体为双向单排配筋。对其进行了低周反复荷载下的抗震性能试验研究,分析了其承载力、延性、刚度及其退化过程、滞回特性、耗能能力和破坏特征。研究表明:在墙体的配筋率相同情况下,由于单排配筋墙体钢筋的间距相对于双排配筋墙体钢筋间距小,其首先约束混凝土裂缝的几率更大,其平面内的抗震性能优于双排配筋剪力墙;由于剪力墙的翼缘和腹板共同工作,单排配筋剪力墙平面外的性能也可满足多层剪力墙结构设计的要求。  相似文献   

7.
以嵌缝胶泥作为嵌缝材料,针对不同高宽比和不同配筋率的6片墙体进行了拟静力试验,探讨了嵌筋加固砖砌体墙的破坏特征、变形能力、承载能力、耗能能力、滞回特征及刚度退化等抗震性能,建立了以试验为基础的嵌筋加固砖砌体墙的抗剪承载力计算公式。研究结果表明:高宽比为1.8的试件,嵌筋墙体较无筋墙体水平抗剪极限承载力提高了17%~31%,延性提高了54%~83%;高宽比为0.5的试件,嵌筋墙体较无筋墙体水平抗剪极限承载力提高了13%~17%,延性提高了17%~20%,嵌筋加固墙体滞回环饱满,耗能能力有较大幅度提高,破坏形式由脆性破坏转变为延性破坏,嵌筋对墙体初始刚度的影响较小,给出的抗剪承载力公式计算值与试验值接近,为工程应用奠定了基础。  相似文献   

8.
双向单排配筋混凝土低矮剪力墙抗震性能试验研究   总被引:6,自引:2,他引:4  
双向单排配筋混凝土低矮剪力墙适用于多层住宅结构。对4个原型的剪跨比为1.0配筋混凝土低矮剪力墙进行了低周反复荷载试验研究,包括1个双向双排配筋混凝土低矮剪力墙和3个双向单排配筋混凝土低矮剪力墙。其中1个双向单排配筋混凝土低矮剪力墙加设暗支撑,用以研究暗支撑对这种新型墙体的作用。在试验研究的基础上,对比分析了各剪力墙的刚度及其衰减过程、承载力、延性、滞回特征、耗能能力及破坏特征。试验表明,经过合理设计,这种双向单排配筋混凝土低矮剪力墙可以满足多层住宅结构抗震要求。  相似文献   

9.
为了研究设窗洞的蒸压加气混凝土砌块砌体承重墙的抗震性能,运用ABAQUS有限元分析软件对其进行了非线性分析。首先将有限元模型的计算结果与足尺试件的试验结果进行了对比验证,在此基础上,通过改变墙体的竖向压应力、水平配筋和开洞大小,研究了这些参数对墙体抗震性能的影响。研究表明:随着竖向压应力的增大,墙体水平承载力提高,而极限变形能力则有降低趋势;水平配筋可以提高墙体的承载力和变形性能;增大洞口水平尺寸导致极限承载力明显降低,而对其相应位移的影响则小得多。  相似文献   

10.
根据2014年云南地区M6.1盈江地震、M6.5鲁甸地震和M6.6景谷地震的主震、余震P波初期部分的信息,研究了地震震级快速估算中3个预警参数(最大卓越周期τpmax、特征周期τc和最大位移幅值Pd)与震级的相关性,提出了云南地区的震级估计模型,并对其进行分析,再和其它地区的震级估计模型进行对比和评价。结果表明:3种方法均能在短时间内(2~4 s)有效地进行震级估算,Pd方法估算效果最优,τc方法次优,τpmax方法较弱。在震级较大的主震震级估计中,3种方法均没有出现明显的震级低估(震级饱和)现象。对于τpmax方法,云南地区的估计模型与南加州地区较为接近,但与四川地区区别较大,可能与该方法的计算稳定性有关;而τc方法的估计模型则与四川及世界其它地区均较为接近,更具有普适性和稳定性。在地震预警系统的实际应用中,由于云南地区尚未建立密集的地震监测台网系统,因此在短时间内难以得到较为准确的震中距。与震源距相独立的τpmax和τc两种算法则显得较为实用,其中:τc方法略优于τpmax方法,同时能较好地满足地震预警系统的精度要求,因此推荐使用τc方法应用于云南地区地震预警系统中的快速震级估算。  相似文献   

11.
通过2根圆钢管普通混凝土柱与5根圆钢管钢渣混凝土柱在高轴压比下的水平低周反复加载试验,研究圆钢管钢渣混凝土柱的轴压比、钢管壁厚、钢渣砂替代率和长细比对其破坏形态、滞回耗能能力、骨架曲线、延性及耗能、刚度退化的影响规律。研究结果表明:钢渣混凝土试件破坏过程和破坏形态与普通混凝土试件基本相同,主要表现为钢管底部鼓曲的压弯破坏;所有试件滞回曲线饱满,无明显“捏缩”现象;高轴压比试件存在明显承载力突降现象,合理的径厚比(钢管直径/钢管壁厚)对高轴压比试件承载力突降有明显改善作用;低轴压比试件延性系数大于4.0,高轴压比试件延性系数介于1.57~3.76之间,轴压比增大,试件延性下降;试件破坏时等效粘滞阻尼系数ξeq介于0.259~0.437之间;建议采用《钢管混凝土混合结构技术标准》(GB/T51446-2021)或《钢管混凝土结构技术规程》(DBJ/T13-51-2010)计算地震作用下钢管钢渣混凝土柱压弯承载力,但高轴压比钢管钢渣混凝土柱计算结果需乘以折减系数0.8。  相似文献   

12.
通过对采用高强钢筋的6片T形混凝土短肢剪力墙和采用高强钢筋高强混凝土的6片L形短肢剪力墙进行低周往复加载试验,研究了T形和L形的破坏形态与性能差异,分析了高厚比、轴压比、配箍间距等参数对构件破坏形态、滞回耗能、骨架曲线、延性及耗能等抗震性能的影响,对比分析了构件与普通短肢剪力墙的抗震性能差异。试验结果表明:采用腹板端部箍筋加密的方式可减轻构件端部的损伤和降低正负向加载时承载力和延性的不对称性;T形构件中高厚比为5的试件表现为弯曲破坏,其他构件表现为弯剪破坏;试验中高厚比小的构件相对于高厚比大的试件延性耗能更好,轴压比增大,构件承载力提高但延性降低;与普通短肢剪力墙相比,T形短肢剪力墙承载力和变形能力提高,耗能增加,L形短肢剪力墙承载力提高较大,极限位移增大,构件后期变形能力略有降低,但可以满足抗震性能要求。  相似文献   

13.
Reinforced concrete (RC) precast shear walls are extensively applied in practical engineering, owing to their fast construction speed. However, because of the transport conditions, RC precast shear walls have to be separated into small wall segments during the factory prefabrication procedure before being assembled on site. Typically, wet-type jointing methods are adopted to link the segments, which is time-consuming and results in unreliable post-pouring area strength. To overcome this problem, the novel scheme of the steel shear key (SSK) featuring steel shear panels and combined fillet and plug welding is proposed. Three RC precast shear wall specimens with different linking strength, termed as weakened SSK wall, standard SSK wall, and strengthened SSK wall, respectively, and an integrated shear wall specimen were designed. Quasi-static cyclic loading was applied to investigate the specimens' dynamic properties. The test results suggest the prefabricated wall segments equipped with SSKs showed reliable stiffness and bearing capacity and were improved in energy dissipation ability, compared with conventional shear walls. As the shear stiffness and number of equipped SSKs increased, the specimens exhibited higher strength, but their ductility and energy dissipation were slightly decreased. Most importantly, the standard SSK wall specimen could achieve satisfactory bearing capacity and deformability and is thus recommended for precast building structures. Finite element method (FEM) models were established to validate the test results, and parametric study analysis was conducted based on the coupling ratio of the SSK walls. Finally, an appropriate coupling ratio range is recommended for practical engineering applications.  相似文献   

14.
为验证新型装配式圆钢管柱-钢梁节点的破坏模式及抗震性能,进行了3个十字形节点的低周反复循环加载试验。研究了不同试件节点的破坏模式、滞回性能、延性及耗能性能等。试验结果表明:试件的位移延性系数为3.38~3.44,能量耗散系数为1.72~2.25,节点具有良好的滞回性能、延性及耗能能力,满足现行规范设计要求。建议在采用新型装配式节点时,梁柱连接处可同时采用加强型连接或骨式连接,以获得良好的抗震性能。  相似文献   

15.
Values of bulk modulus (K), shear modulus (G) and mechanical quality factor (Q) have been determined for polycrystalline samples across the CaTiO3 (CST0)–SrTiO3 (CST100) solid solution by resonant ultrasound spectroscopy. Because of similarities with low frequency elastic and anelastic anomalies due to twin wall motion reported in previous studies, a working hypothesis is developed in which dissipation processes are interpreted in terms of twin wall displacements. At high temperatures in CST50 the stability field of the I4/mcm structure is marked by the disappearance of all resonance peaks (superattenuation). This is attributed to anelastic domain wall sliding. At room temperature the I4/mcm phase of CST70 and CST80 has values of G which are lower than those of cubic or orthorhombic phases, and a concomitant drop in Q is interpreted as implying that the domain wall pinning process reported elsewhere to occur below 400–450 K is only partial. A similar drop in G and Q was found in CST95 below the transition at 238 K. The I4/mcm ↔ Pbcm transition in CST70 at 230 K is marked by an abrupt increase in Q, suggesting that mobile twins in crystals with the I4/mcm structure become effectively immobile in antiferroelectric crystals with the Pbcm structure. The I4/mcm ↔ Pnma transition in CST50 is marked by a similarly abrupt increase in Q, consistent with twin walls becoming effectively immobile also in crystals with the Pnma structure. A fall in Q below 800 K in CST0, however, could imply that a degree of twin wall mobility might develop in Pnma crystals if the tetragonal spontaneous strain departs significantly from zero. The remarkable attenuation behaviour of crystals with the I4/mcm structure at the relatively low stress conditions which apply during resonances of a parallelepiped with edge dimensions of 2–4 mm, is consistent with the view that a characteristic signature for tetragonal CaSiO3 in the Earth's lower mantle should be a marked attenuation of seismic waves.  相似文献   

16.
利用超弹性SMA螺栓梁柱节点的耗能能力和自复位特性,将其引入到耗能跨而构建"自复位耗能跨",基于既有的节点试验研究结果对结构体系的滞回性能进行了探讨。在此基础上,以具有旗形滞回特征的单自由度体系为工具,对配置自复位耗能跨低多层钢框架体系的能量系数进行推导。能量系数可以合理量化具有旗形滞回规则结构的峰值响应需求,能量系数越低,表明地震动下结构的峰值响应越低。为了阐明滞回参数对能量系数的影响,对具有不同滞回参数组合可代表低多层结构的等效SDOF体系进行了非线性动力分析,参数组合包括周期、屈服后刚度比、延性系数及能量比。同时对能量系数的离散性也进行了分析。结果表明:能量系数及能量系数的离散性受结构周期、屈服后刚度比及延性系数影响较大,受能量比的影响较小。  相似文献   

17.
王恒  杨振宇 《地球物理学报》2019,62(5):1789-1808
印度—欧亚板块碰撞以来青藏高原内部及其周缘地区经历了复杂的构造演化,复杂构造变形区的复合构造使得古地磁的数据解释究竟代表区域的构造旋转还是只能反映局部的构造变形一直是备受关注的问题.本文通过采集川滇地块西缘渔泡江断裂东侧三岔河地区白垩纪红层古地磁样品,揭示采样区差异性旋转并探讨川滇地块西部自中新世以来的构造演化规律.前人的地质调查表明川滇地块渔泡江断裂东侧上白垩统赵家店组地层发育倾伏褶皱.三岔河剖面以三岔河镇为界分为南北两段,三岔河南段剖面高温剩磁分量平均方向在倾斜校正后Ds=29.3°,Is=45.7°,ks=54.3,α95=6.6°,倾伏地层产状校正后Ds=30.6°,Is=46.6°,ks=69.3,α95=5.8°;而三岔河北侧剖面高温剩磁分量平均方向在倾斜校正后Ds=350.4°,Is=42.1°,ks=69.4,α95=9.2°,倾伏地层产状校正后Ds=347.4°,Is=41.9°,ks=96.6,α95=7.8°;两组高温剩磁分量均通过了褶皱检验,表明其获得于褶皱形成之前.相对于东亚稳定区80Ma古地磁极,三岔河南侧剖面发生了20.5°±4.8°的顺时针构造旋转量,与楚雄盆地核部之间不存在差异性旋转;但三岔河镇以北剖面却发生了22.7°±6.6°的逆时针旋转.综合分析川滇地块内部的古地磁数据表明自中新世以来川滇地块南部楚雄盆地经历了约20°的顺时针构造旋转,而三岔河镇北侧经历了约20°逆时针旋转.进一步分析表明三岔河北侧剖面相对于南侧剖面经历了约40°的逆时针旋转,可能由于研究区的滑脱构造导致岩石薄弱层拆离滑脱所引起.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号