首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
This study assesses the seismic performance of a hybrid coupled wall (HCW) system with replaceable steel coupling beams (RSCBs) at four intensities of ground motion shaking. The performance of the HCW system is benchmarked against the traditional reinforced concrete coupled wall (RCW). Nonlinear numerical models are developed in OpenSees for a representative wall elevation in a prototype 11‐story building designed per modern Chinese codes. Performance is assessed via nonlinear dynamic analysis. The results indicate that both systems can adequately meet code defined objectives in terms of global and component behavior. Behavior of the two systems is consistent under service level earthquakes, whereas under more extreme events, the HCW system illustrates enhanced performance over the RCW system resulting in peak interstory drifts up to 31% lower in the HCW than the RCW. Larger drifts in the RCW are because of reduced coupling action induced by stiffness degradation of RC coupling beams, whereas the stable hysteretic responses and overstrength of RSCBs benefit post‐yield behavior of the HCW. Under extreme events, the maximum beam rotations of the RSCBs are up to 42% smaller than those of the RC coupling beams. Moderate to severe damage is expected in the RC coupling beams, whereas the RSCBs sustain damage to the slab above the beam and possible web buckling of shear links. The assessment illustrates the benefits of the HCW with RSCBs over the RCW system, because of easy replacement of the shear links as opposed to costly and time‐consuming repairs of RC coupling beams. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.  相似文献   

3.
Reinforced concrete (RC) shear walls have been extensively used as lateral load resisting structural members in tall buildings. However, in the past, strong earthquake events RC structural walls in some buildings suffered severe damage, which concentrated at the bottom and was very difficult to be repaired. The installation of the replaceable corner components (RCCs) at the bottom of the structural wall is a new method to form an earthquake resilient structural wall whose function can be quickly restored by replacing the RCCs after the strong earthquake because of the damage concentrating on RCCs. In this study, a new kind of replaceable energy‐dissipation component installed at the bottom corner of RC structural walls was proposed. To study the seismic performance of the new structural wall with RCCs, the cyclic loading tests on three new structural wall specimens and one conventional RC structural wall specimen were conducted. One of the new structural wall specimens experienced replacement and reloading process to verify the feasibility of replacement. The results show that the structural behavior of all specimens was flexure dominating. The damage in the new shear specimens mainly concentrated on RCCs. The replacement of RCCs can be implemented conveniently after the residual deformation occurred in the structure. Compared with the conventional structural wall specimen, the seismic performance of new structural wall specimens was improved significantly. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

4.
Improving seismic performance is one of the critical objectives in earthquake engineering. With the development of economy and society, reparability and fast resilience of a structure are becoming increasingly important. Reinforced concrete (RC) frame structure is prone to soft story mechanism. As a result, deformation and damage are so concentrated that reparability is severely hampered. Rocking wall provides an available approach for deformation control in RC frame by introducing a continuous component along the height. Previous researches mostly focus on seismic responses of rocking wall frame structures, while damage mode and reparability have not been investigated in detail. In this study, a novel infilled rocking wall frame (IRWF) structure is proposed. A half‐scaled IRWF model was designed according to Chinese seismic design code. The model was subjected to cyclic pushover testing up to structure drift ratio of 1/50 (amplitude 1/50), and its reparability was evaluated thereafter. Retrofit was implemented by wrapping steel plates and installing friction dampers. The retrofitted model was further loaded up to amplitude 1/30. The IRWF model showed excellent reparability and satisfactory seismic performance on deformation control, damage mode, hysteresis behavior, and beam‐to‐column joint rotation. After retrofitting, capacity of the model was improved by 11% with limited crack distribution. The model did not degrade until amplitude 1/30, due to shear failure in frame beams. The retrofit procedure was proved effective, and reparability of the IRWF model was demonstrated. Seismic resilience tends to be achieved in the proposed system.  相似文献   

5.
将参数化建模的方法引入减震结构的分析与设计中,通过预设目标和迭代优化计算,以天水市某高层住宅消能减震结构为例,寻找最优的阻尼器布置方案。为评估和验证该消能减震结构的抗震性能,分别采用Perform 3D和ETABS等软件分析结构在多遇和罕遇地震作用下的结构响应,分析结果表明:小震作用下,消能减震结构的楼层位移、层间位移角、楼层弯矩及楼层剪力均减小6.5%以上,达到了设计要求;大震作用下,结构框架柱、框架梁、剪力墙和阻尼器能够满足既定的性能要求,层间位移角满足规范限值,能够达到“大震不倒”的设计目标,研究结果为实际工程预设减震目标和阻尼器优化布置提供参考。  相似文献   

6.
钢筋混凝土剪力墙结构通过设置可更换连梁,在地震作用下集中损伤,保护主体结构不受或只受微小破坏,震后更换损伤构件即可恢复结构功能。参照现行规范和已有试验分析结果,在普通钢筋混凝土结构设计基础上,提出带有可更换连梁的钢筋混凝土结构实用设计方法,设定性能目标,总结设计流程。采用提出的设计方法对1个50层钢筋混凝土结构进行设计,并采用大型有限元分析软件ABAQUS建立数值模型,验证结构性能目标和提出的设计方法。结果表明:按该方法设计的带有可更换连梁的钢筋混凝土结构能满足所设定的性能目标,设计方法合理实用,为该新型结构的工程应用提供了参考。  相似文献   

7.
钢管混凝土结构已经广泛应用于我国高层和超高层建筑中,为研究该类结构的抗震性能,分别采用分离模量法和统一模量法对某13层钢管混凝土框架结构进行抗震性能分析,研究不同地震波作用下组合框架的模态和多遇地震下的弹性动力时程,对比组合框架顶点位移反应、加速度反应、层间侧移及动力放大系数等。研究结果表明,分离模量法和统一模量法建模方法在分析钢管混凝土框架抗震动力特性上总体相差不大,但前者可以考虑材料弹塑性,从而对结构弹塑性进行分析,而后者在弹塑性阶段需要用全曲线表达式,尚需进一步的研究。  相似文献   

8.
A three‐dimensional beam–truss model (BTM) for reinforced concrete (RC) walls that explicitly models flexure–shear interaction and accurately captures diagonal shear failures was presented in the first part of this two‐paper series. This paper extends the BTM to simulate RC slabs and coupled RC walls through slabs and beams. The inclination angle of the diagonal elements for coupled RC walls is determined, accounting for the geometry of the walls and the level of coupling. Two case studies validate the model: (1) a two‐bay slab–column specimen experimentally tested using cyclic static loading and (2) a five‐story coupled T‐wall–beam–slab specimen subjected to biaxial shake table excitation. The numerically computed lateral force–lateral displacement and strain contours are compared with the experimentally measured response and observed damage. The five‐story specimen is characterized by diagonal shear failure at the bottom story of the walls, which is captured by the BTM. The BTM of the five‐story specimen is used to study the effects of coupling on shear demand for lightly reinforced RC coupled walls. The effect of mesh refinement and bar fracture of non‐ductile transverse reinforcement is studied. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
为研究高层RC框架结构罕遇地震下的易损性,设计了一个7度区典型11层RC框架结构。采用IDA方法进行时程分析,以地震动峰值地面加速度和结构第一自振周期对应的谱加速度为地震动强度指标,最大层间位移角为结构损伤指标,分别得到了单一地震动强度和双地震动强度参数下的IDA曲线和失效概率,绘制了双地震动强度参数下易损性曲面,并对单一地震动强度和双地震动强度参数下的易损性分析结果进行了对比。结果表明:罕遇地震下,采用双地震动强度参数结构失效概率明显低于采用单一地震动强度参数结构失效概率;对高层RC框架结构,采用双地震动强度参数进行易损性分析反映的地震动信息更全面;采用双地震动强度参数得到的结构失效概率公式更能真实量化不同强度地震作用下结构的失效概率。  相似文献   

10.
This paper reports a study for the seismic performance of one large‐scaled (1/15) model of 30‐story steel‐reinforced concrete frame‐concrete core wall mixed structure. The study was implemented by both shaking table tests, in which the similarity ratio for lateral and gravitational accelerations was kept to 1:1, and numerical nonlinear dynamic analysis. The test observations presented herein include story displacement, interstory drift, natural vibration periods, and final failure mode. The numerical analysis was performed to simulate the shaking table test procedure, and the numerically obtained responses were verified by the test results. On the basis of the numerical results, the progressions of structural stiffness, base shear, and overturning moment were investigated, and the distributions of base shear and overturning moment between frame and core wall were also discussed. The test demonstrates the seismic performance of the steel‐reinforced concrete frame‐core wall mixed structure and reveals the potential overturning failure mode for high rise structures. The nonlinear analysis results indicate that the peripheral frames could take more shear forces after core wall damaged under severe earthquakes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
带耗能腋撑竖向不规则短肢剪力墙结构减震性能分析   总被引:2,自引:0,他引:2  
在不影响建筑使用空间前提下,提出在抗侧构件不连续处设置耗能腋撑以改善竖向不规则结构抗震性能。以底部大空间短肢剪力墙结构为研究对象,利用大型通用有限元程序ETABS研究耗能器类型与场地土对耗能腋撑工作性能和竖向不规则结构受力性能的影响。研究表明,黏滞型耗能腋撑对文中分析模型各楼层地震反应有较好的控制效果,对转换层处层间位移角与层剪力最大值减幅最大,分别为40.14%和15.66%,对顶层加速度与基底剪力峰值的最大减幅分别为16.06%和23.57%,黏滞型耗能腋撑最大能耗散输入结构能量的42%,而黏弹型耗能腋撑对结构的控制效果不理想;当地震震级较大、震中距较小时,耗能腋撑对坚硬与软弱场地土的模型结构控制作用相差不大,减震位移比在转换层处达到最小值0.76;随着震级减小或震中距增大,耗能腋撑对该模型结构的控制作用随场地土变硬而逐渐增强,其减震位移比介于0.68~0.74之间。  相似文献   

12.
The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination of unbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.  相似文献   

13.
三层地铁车站振动台试验分析   总被引:3,自引:0,他引:3  
为了探究多层地下结构地震破坏机理,进行了三层地铁车站振动台试验.试验采用微粒混凝土模型,严格按照相似比和配筋率对模型进行加筋配置.填土采用哈尔滨地铁施工挖掘出的扰动土.装土箱采用自主研制的层叠剪切箱以减小边界效应.通过对试验加速度和应变的分析可得到以下主要结论:(1)地下结构在地震中的破坏,主要是由位移控制的;(2)多...  相似文献   

14.
针对传统结构震后修复能力不足,带可更换构件的混合框架结构体系在地震作用下,可更换耗能构件集中损伤和耗散地震能量,保护其他构件不损伤或轻微损伤,更换损伤的耗能构件,即可实现结构预定功能震后可恢复。通过3个可更换耗能梁试件,研究其抗震性能。在此基础上,通过SAP2000有限元建模,对带可更换构件的混合框架结构进行非线性分析,研究整体结构体系的屈服机制、承载力和可更换耗能构件的可更换性能。结果表明:试件均发生剪切屈服型破坏,破坏特征包括腹板-加劲肋焊缝撕裂、腹板屈曲和腹板撕裂。各试件的滞回曲线非常饱满,具有优异的承载能力、变形能力和耗能能力;在地震作用下,带可更换构件的混合框架结构体系中各构件能够实现良好的有序屈服机制,可更换耗能构件具有较好的可更换性。  相似文献   

15.
安装形状记忆合金阻尼器的剪力墙结构抗震性能分析   总被引:1,自引:0,他引:1  
为减轻钢筋混凝土剪力墙连梁的地震后永久性损伤,同时保持连梁的耗能机制,本文提出在剪力墙连梁中安装新型形状记忆合金(Shape Memory Alloy,简称SMA)阻尼器,并研究该阻尼器对剪力墙结构地震响应的减震效果。通过一幢12层剪力墙结构地震反应的时程分析,研究了SMA阻尼器的附加刚度比和屈服位移比两项特征参数对结构地震反应控制效果的影响规律。计算分析结果表明,当附加刚度比为0.04~0.05,屈服位移比为0.4~0.5时,可以获得较好的减震效果。  相似文献   

16.
This paper presents an analytical investigation on the seismic design and response of coupled wall structures that use unbonded post‐tensioned steel coupling beams. Both monolithic cast‐in‐place reinforced concrete wall piers and precast concrete wall piers are considered. Steel top and seat angles are used at the coupling beam ends for energy dissipation. The seismic design of prototype structures to achieve target displacement‐based performance objectives is evaluated based on nonlinear static and dynamic time history analyses. Additional recommendations are provided on shear design. Comparisons with ‘conventional’ structures that use embedded steel coupling beams as well as isolated walls with no coupling are provided. The results indicate that while the peak lateral displacements of unbonded post‐tensioned coupled wall structures are larger than the peak displacements of structures with embedded beams, the residual displacements are significantly reduced as a result of the restoring effect of the post‐tensioning steel. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
The seismic design of multi‐story buildings asymmetric in plan yet regular in elevation and stiffened with ductile RC structural walls is addressed. A realistic modeling of the non‐linear ductile behavior of the RC walls is considered in combination with the characteristics of the dynamic torsional response of asymmetric buildings. Design criteria such as the determination of the system ductility, taking into account the location and ductility demand of the RC walls, the story‐drift demand at the softer (most displaced) edge of the building under the design earthquake, the allowable ductility (ultimate limit state) and the allowable story‐drift (performance goals) are discussed. The definition of an eccentricity of the earthquake‐equivalent lateral force is proposed and used to determine the effective displacement profile of the building yet not the strength distribution under the design earthquake. Furthermore, an appropriate procedure is proposed to calculate the fundamental frequency and the earthquake‐equivalent lateral force. A new deformation‐based seismic design method taking into account the characteristics of the dynamic torsional response, the ductility of the RC walls, the system ductility and the story‐drift at the softer (most displaced) edge of the building is presented and illustrated with an example of seismic design of a multi‐story asymmetric RC wall building. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

18.
As a result of population growth and consequent urbanization, the number of high‐rise buildings is rapidly growing worldwide resulting in increased exposure to multiple‐scenario earthquakes and associated risk. The wide range in frequency contents of possible strong ground motions can have an impact on the seismic response, vulnerability and limit states definitions of RC high‐rise wall structures. Motivated by the pressing need to derive more accurate fragility relations to be used in seismic risk assessment and mitigation of such structures, a methodology is proposed to obtain reliable, Seismic Scenario‐Structure‐Based (SSSB) definitions of limit state criteria. A 30‐story wall building, located in a multi‐seismic scenario study region, is utilized to illustrate the methodology. The building is designed following modern codes and then modeled using nonlinear fiber‐based approach. Uncertainty in ground motions is accounted for by the selection of forty real earthquake records representing two seismic scenarios. Seismic scenario‐based building local response at increasing earthquake intensities is mapped using Multi‐Record Incremental Dynamic Analyses (MRIDAs) with a new scalar intensity measure. Net Inter‐Story Drift (NISD) is selected as a global damage measure based on a parametric study involving seven buildings ranging from 20 to 50 stories. This damage measure is used to link local damage events, including shear, to global response under different seismic scenarios. While the study concludes by proposing SSSB limit state criteria for the sample building, the proposed methodology arrives at a reliable definition of limit state criteria for an inventory of RC high‐rise wall buildings under multiple earthquake scenarios. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
钢筋混凝土核心筒性态水平及性能指标限值研究   总被引:1,自引:0,他引:1  
结合国内外对钢筋混凝土结构性能水平的划分标准并根据核心筒结构破坏特征及抗震性能要求,文中在现行规范基础上进一步细分,将钢筋混凝土核心筒结构的性能水准划分为良好使用、暂时使用、生命安全和接近倒塌4个水平;基于混凝土连梁及剪力墙构件的受力、变形及破坏特点,分别提出了连梁及剪力墙构件对应于4个性能水平的失效判别标准和变形限值...  相似文献   

20.
A wall‐type friction damper is newly proposed in this paper to improve the performance of reinforced concrete (RC) framed structures under earthquake loads. Traditionally, the damper was generally invented as a brace‐type member. However, it has been seen to cause problems in the RC frame structures in that concrete is apt to be damaged in the connection regions of the RC member and the brace‐type damper under earthquake loads. The proposed wall‐type damper has an advantage in the retrofit of RC structures. The system consists of a Teflon® slider and a RC wall. The damper is also designed to control normal pressures acting on a frictional slider. The numerical applications show that the proposed damper can be effective in mitigating the seismic responses of RC frame structures and reducing the damage to RC structural members. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   