首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Steel plate shear walls (SPSWs) are used as lateral force‐resisting systems in new and retrofitted structures in high‐seismic regions. Various international codes recommend the design of SPSWs assuming the entire lateral load to be resisted by the infill plates. Such a design procedure results in significant overstrength leading to uneconomical and inefficient use of materials. This study is focused on the estimation of contribution of boundary elements in resisting the lateral force considering their interaction with the web plates of SPSW systems. Initially, the relative contribution of web plates and boundary frames is computed for a single‐bay single‐story frame with varying rigidity and end connections of boundary elements. Nonlinear static analyses are carried out for the analytical models in OpenSees platform to quantify this contribution. Later, this study is extended to the code‐based designed three‐story, six‐story, and nine‐story SPSWs of varying aspect ratios. Based on the results obtained, a new design procedure is proposed taking the lateral strengths of the boundary frames into account. Nonlinear time‐history analyses are conducted for 40 recorded ground motions representing the design basis earthquake and maximum considered earthquake hazard levels to compare the interstory and residual drift response and yield mechanisms of SPSWs designed as per current practice and the proposed methodology. Finally, an expression has been proposed to predict the lateral force contribution of the infill plate and the boundary frame of SPSWs. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
The steel plate shear wall (SPSW) is an effective lateral force resisting system in which unstiffened steel infill plates are connected to the horizontal and vertical boundary elements (VBEs) on all sides of the plates. The boundary elements must be designed to resist the tension field force of the infill panels. When the VBEs are made from a steel box section, the flange of each box VBE connected with the infill panels can be pulled out‐of‐plane by significant panel forces, called pull‐out action. This study investigates capacity design methods for box VBEs in SPSWs. Simplified fixed beam and portal frame models aim to estimate the pull‐out responses of the flange of the box sections with and without infill concrete, respectively. In this study, cyclic tests of three full‐scale two‐story SPSWs using box VBEs with or without the infill concrete are conducted. Inelastic pushover analyses of the finite element models are conducted. The tests and analytical results confirm that the proposed design methods, which aimed to prevent the full yield of the flange under the pull‐out action, are applicable. Furthermore, the test and analytical results suggest that the initial yielding of the flange of box VBEs under the collective effects of the pull‐out action on the flange, the gravity load, and the sway action on the SPSW represents a local yielding. A strict prohibition of the initial yielding on the flange under the aforementioned collective effects is not recommended for pursuing a cost‐effective design. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

3.
This research investigates the seismic design method and the cyclic inelastic behavior of the bottom column, also called the vertical boundary element (VBE), in steel plate shear walls (SPSWs). This study consists of two parts. This Part 1 paper discusses the anticipated pushover responses for properly designed SPSWs and the possible inelastic responses of the bottom VBE at various levels of inter‐story drift. Considering both the tension field action of the infill panel and the sway action of the boundary frame, this study develops a simplified method to compute the flexural and shear demands in the bottom VBE. Based on the superposition method, this approach considers various plastic hinge forming locations at different levels of inter‐story drift. One of the key performance‐based design objectives is to ensure that the top ends of the bottom VBEs remain elastic when the SPSWs are subjected to the maximum considered earthquake. This paper presents the comprehensive design procedures for the bottom VBE. Furthermore, this study conducted cyclic performance evaluation tests of three full‐scale two‐story SPSWs at the Taiwan National Center for Research on Earthquake Engineering in 2011 to validate the effectiveness of the proposed design methods. The experimental program, cyclic inelastic responses of the SPSWs and bottom VBEs, and numerical simulations are presented in Part 2. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
The steel plate shear wall (SPSW) system is a robust option for earthquake resistance due to the strength, stiffness, ductility and energy dissipation that it provides. Although thin infill plates are efficient for resisting lateral loads, boundary frames that are proportioned based on capacity design requirements add significant structural weight that appears to be one of the factors limiting the use of the system in practice. An alternate configuration, the SPSW with coupling (SPSW‐WC), was explored recently as an option for increasing architectural flexibility while also improving overall system economy and seismic performance. The SPSW‐WC, which extensively employs flexural boundary frame contribution, has shown promise in analytical, numerical and experimental studies, but recent research on uncoupled SPSWs suggests that boundary frame contribution should not be considered for carrying seismic design shear. As a result, in the present study, boundary frame contribution in SPSWs was explored with detailed three‐dimensional finite element models, which were validated against large‐scale SPSW‐WC tests. Six‐story systems were considered, and the study matrix included single and double uncoupled SPSWs along with coupled SPSWs that had various degrees of coupling. Variations in design methodology were also explored. The modeling framework was employed to conduct static monotonic and cyclic pushover analyses and dynamic response history analysis. These analyses demonstrate the beneficial effect of coupling in SPSWs and illustrate the need to consider boundary frame contribution in design of coupled SPSWs. In addition, sharing design shear between the infill plate and the boundary frame is more generally shown to not be detrimental if this sharing is done in the design stage based on elastic analysis and the resulting boundary frame provides adequate secondary strength and stiffness following infill plate yielding. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

5.
Previous research has shown that self‐centering steel plate shear walls (SC‐SPSWs) are capable of achieving enhanced seismic performance at multiple hazard levels, including recentering following design‐level earthquakes. When modeling SC‐SPSWs numerically, these studies considered an idealized tension‐only steel plate shear wall (SPSW) web plate behavior. Research has shown that web plate behavior is more complex than predicted by the idealized model, and web plates can provide more strength, stiffness, and energy dissipation than predicted by the idealized model. The idealized model of web plate behavior is used widely in SPSW numerical models where the moment‐resisting boundary frame provides supplemental hysteretic damping and stiffness; however, in SC‐SPSWs, where the post‐tensioned boundary frame is designed to remain elastic during an earthquake, accounting for the more complex web plate behavior can have a significant impact on seismic performance estimates from numerical simulation. This paper presents different methods for modeling SC‐SPSWs. Responses from these models are compared with experimental results. A simple modification of the tension‐only model, referred to as the tension‐compression strip model, is shown to provide a reasonable approximation of SC‐SPSW behavior. Results from nonlinear response history analyses of SC‐SPSWs with the tension‐only and tension‐compression web plate models are compared to assess how the approximation of web plate behavior affects SC‐SPSW seismic performance. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
This paper describes an experiment to investigate the seismic design and responses of the bottom column, also called the bottom vertical boundary element (VBE), in steel plate shear walls (SPSWs). The main objectives of this experiment include validating the effectiveness of the design method developed in the companion paper, investigating the experimental performance of VBEs under large interstory drifts, and calibrating analytical models for earthquake engineering of SPSWs. Three full‐scale two‐story SPSWs were cyclically tested at the Taiwan National Center for Research on Earthquake Engineering in 2011. Test results and numerical simulations confirm that the proposed design procedures are effective in predicting the plastic zone forming elevation in the lower half of the bottom VBE and the occurrence of yielding at the VBE's top end. Test results show that the premature yielding occurring at the top end of a bottom VBE would result in a deformation concentration at the bottom of SPSWs. In addition, lateral torsional buckling could take place on the bottom VBE after significant plastic rotations have developed at the top end. Test results suggest that preventing the VBE's top end from yielding is the key issue in the seismic design of SPSWs, and the proposed method can be effectively adopted to achieve this objective. Furthermore, the inelastic responses of the SPSW specimens were satisfactorily simulated by using detailed finite shell elements or simplified frame response analysis models. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
A new floor connecting system developed for low‐damage seismic‐resistant building structures is described herein. The system, termed Inertial Force‐Limiting Floor Anchorage System (IFAS), is intended to limit the lateral forces in buildings during an earthquake. This objective is accomplished by providing limited‐strength deformable connections between the floor system and the primary elements of the lateral force‐resisting system. The connections transform the seismic demands from inertial forces into relative displacements between the floors and lateral force‐resisting system. This paper presents the IFAS performance in a shake‐table testing program that provides a direct comparison with an equivalent conventional rigidly anchored‐floor structure. The test structure is a half‐scale, 4‐story reinforced concrete flat‐plate shear wall structure. Precast hybrid rocking walls and special precast columns were used for test repeatability in a 22‐input strong ground‐motion sequence. The structure was purposely designed with an eccentric wall layout to examine the performance of the system in coupled translational‐torsional response. The test results indicated a seismic demand reduction in the lateral force‐resisting system of the IFAS structure relative to the conventional structure, including reduced shear wall base rotation, shear wall and column inter‐story drift, and, in some cases, floor accelerations. These results indicate the potential for the IFAS to minimize damage to the primary structural and non‐structural components during earthquakes.  相似文献   

8.
为研究底部放置聚苯乙烯硬泡沫板的抗震性能,对3个剪跨比2.0的两端设置后浇段、底部放置聚苯乙烯硬泡沫板的预制剪力墙试件以及1个相同剪跨比的现浇剪力墙试件进行了拟静力试验。试验结果表明:预制剪力墙底部放置硬聚苯乙烯泡沫板的试件,破坏形态为后浇段与预制剪力墙脱开、后浇段受压破坏;底部放置聚苯板的预制剪力墙试件承载力小于现浇剪力墙试件,耗能能力接近或大于现浇剪力墙试件;各试件的极限位移角为1/98~1/81;预制剪力墙试件的屈服刚度及峰值刚度均比现浇剪力墙试件降低27%~75%,水平分布钢筋未伸入后浇段的试件比伸入后浇段的试件刚度降低更多,后浇段短的试件比后浇段长的试件刚度降低更多。预制试件轴压力主要由后浇段承担,名义屈服及峰值水平力时,钢筋应变分布不符合平截面假定。  相似文献   

9.
This paper evaluates the seismic resistance of steel moment resisting frames (MRFs) with supplemental fluid viscous dampers against collapse. A simplified design procedure is used to design four different steel MRFs with fluid viscous dampers where the strength of the steel MRF and supplemental damping are varied. The combined systems are designed to achieve performance that is similar to or higher than that of conventional steel MRFs designed according to current seismic design codes. Based on the results of nonlinear time history analyses and incremental dynamic analyses, statistics of structural and non‐structural response as well as probabilities of collapse of the steel MRFs with dampers are determined and compared with those of conventional steel MRFs. The analytical frame models used in this study are reliably capable to simulate global frame collapse by considering full geometric nonlinearities as well as the cyclic strength and stiffness deterioration in the plastic hinge regions of structural steel members. The results show that, with the aid of supplemental damping, the performance of a steel MRF with reduced design base shear can be improved and become similar to that of a conventional steel MRF with full design base shear. Incremental dynamic analyses show that supplemental damping reduces the probability of collapse of a steel MRF with a given strength. However, the paper highlights that a design base shear equal to 75% of the minimum design base shear along with supplemental damping to control story drift at 2% (i.e., design drift of a conventional steel MRF) would not guarantee a higher collapse resistance than that of a conventional MRF. At 75% design base shear, a tighter design drift (e.g., 1.5% as shown in this study) is needed to guarantee a higher collapse resistance than that of a conventional MRF. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
The concept of the hybrid passive control system is studied analytically by investigating the seismic response of steel frame structures. Hybrid control systems consist of two different passive elements combined into a single device or system. The hybrid systems investigated in this research consist of a rate‐dependent damping device paired with a rate‐independent energy dissipation element. The innovative configurations exploit individual element strengths and offset their weaknesses through multiphased behavior. A nine‐story, five‐bay steel moment‐frame was used for the analysis. Six different seismic resisting systems were analyzed and compared. The conventional systems included a special moment‐resisting frame (SMRF) and a dual SMRF–buckling‐restrained brace (BRB) system. The final four configurations are hybrid passive systems. The different hybrid configurations utilize a BRB and either a high‐damping rubber damper or viscous fluid damper. The analyses were run in the form of an incremental dynamic analysis. Several damage measures were calculated, including maximum roof drift, base shear, and total roof acceleration. The results demonstrate the capability of hybrid passive control systems to improve structural response compared with conventional lateral systems and to be effective for performance‐based seismic design. Each hybrid configuration improved some aspect of structural response with some providing benefits for multiple damage measures. The multiphased nature provides improved response for frequent and severe seismic events. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
The steel reinforced concrete (SRC) wall consists of structural steel embedded at the boundary elements of a reinforced concrete (RC) wall. The use of SRC walls has gained popularity in the construction of high‐rise buildings because of their superior performance over conventional RC walls. This paper presents a series of quasi‐static tests used to examine the behavior of SRC walls subjected to high axial force and lateral cyclic loading. The SRC wall specimens showed increased flexural strength and deformation capacity relative to their RC wall counterpart. The flexural strength of SRC walls was found to increase with increasing area ratio of embedded structural steel, while the section type of embedded steel did not affect the wall's strength. The SRC walls under high axial force ratio had an ultimate lateral drift ratio of approximately 1.4%. In addition, a multi‐layer shell element model was developed for the SRC walls and was implemented in the OpenSees program. The numerical model was validated through comparison with the test data. The model was able to predict the lateral stiffness, strength and deformation capacities of SRC walls with a reasonable level of accuracy. Finally, a number of issues for the design of SRC walls are discussed, along with a collection and analysis of the test data, including (1) evaluation of flexural strength, (2) calculation of effective flexural stiffness, and (3) inelastic deformation capacity of SRC walls. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
This paper is the second part of a two‐part paper presenting the cyclic tests of four two‐story narrow steel plate shear walls (SPSWs). The first paper introduces the analytical studies and the specimen designs. This paper describes the test results. Some design implications including the capacity design for the first story column and the width‐to‐thickness ratio check for the beam web are discussed based on key observations from the tests. Test results confirm that the simplified strip model can accurately predict the inelastic responses of the specimens. Test results also confirm that the proposed capacity design method is effective in ensuring the plastic hinge formation at the bottom end of the first story column for SPSW with or without restrainers. Test results also show that the horizontal restrainers are effective in reducing the member forces in the boundary beam and column elements. Comparing the test results of the typical SPSW with those of the restrained SPSW (R‐SPSW) specimens, it is found that the R‐SPSW possesses an improved cyclic performance and reduced material weight. Analytical results predict the compressed column moments at the onset of the column plastic hinge formation well. The analytical hysteretic energy distribution in the first story column agrees very well with the observed inelastic actions developed in the four specimens. The detailed frame response analyses and the test results confirm that the assumptions made in developing the proposed column capacity design method are reasonable. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
This paper proposes a novel implementation of buckling‐restrained braces (BRB) in new reinforced concrete (RC) frame construction. Seismic design and analysis methods for using a proposed steel cast‐in anchor bracket (CAB) to transfer normal and shear forces between the BRB and RC members are investigated. A full‐scale two‐story RC frame with BRBs (BRB‐RCF) is tested using hybrid and cyclic loading test procedures. The BRBs were arranged in a zigzag configuration and designed to resist 70% of the story shear. The gusset design incorporates the BRB axial and RCF actions, while the beam and column members comply with ACI 318‐14 seismic design provisions. Test results confirm that the BRBs enhanced the RCF stiffness, strength, and ductility. The hysteresis energy dissipation ratios in the four hybrid tests range from 60% to 94% in the two stories, indicating that BRBs can effectively dissipate seismic input energy. When the inter‐story drift ratio for both stories reached 3.5% in the cyclic loading test, the overall lateral force versus deformation response was still very stable. No failure of the proposed steel CABs and RC discontinuity regions was observed. This study demonstrates that the proposed design and construction methods for the CABs are effective and practical for real applications. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

14.
This paper presents the results of a multi‐level pseudo‐dynamic seismic test program that was performed to assess the performance of a full‐scale three‐bay, two‐storey steel–concrete composite moment‐resisting frame built with partially encased composite columns and partial‐strength beam‐to‐column joints. The system was designed to develop a ductile response in the joint components of beam‐to‐column joints including flexural yielding of beam end plates and shear yielding of the column web panel zone. The ground motion producing the damageability limit state interstorey drift caused minor damage while the ultimate limit state ground motion level entailed column web panel yielding, connection yielding and plastic hinging at the column base connections. The earthquake level chosen to approach the collapse limit state induced more damage and was accompanied by further column web panel yielding, connection yielding and inelastic phenomena at column base connections without local buckling. During the final quasi‐static cyclic test with stepwise increasing displacement–amplitudes up to an interstorey drift angle of 4.6%, the behaviour was ductile although cracking of beam‐to‐end‐plate welds was observed. Correlations with numerical simulations taking into account the inelastic cyclic response of beam‐to‐column and column base joints are also presented in the paper together. Inelastic static pushover and time history analysis procedures are used to estimate the structural behaviour and overstrength factors of the structural system under study. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
An experimental investigation on the seismic behavior of a type of outrigger truss-reinforced concrete wall shear connection using multiple steel angles is presented. Six large-scale shear connection models, which involved a portion of reinforced concrete wall and a shear tab welded onto a steel endplate with three steel angles, were constructed and tested under combined actions of cyclic axial load and eccentric shear. The effects of embedment lengths of steel angles, wall boundary elements, types of anchor plates, and thicknesses of endplates were investigated. The test results indicate that properly detailed connections exhibit desirable seismic behavior and fail due to the ductile fracture of steel angles. Wall boundary elements provide beneficial confinement to the concrete surrounding steel angles and thus increase the strength and stiffness of connections. Connections using whole anchor plates are prone to suffer concrete pry-out failure while connections with thin endplates have a relatively low strength and fail due to large inelastic deformations of the endplates. The current design equations proposed by Chinese Standard 04G362 and Code GB50011 significantly underestimate the capacities of the connection models. A revised design method to account for the influence of previously mentioned test parameters was developed.  相似文献   

16.
A numerical investigation was undertaken to evaluate the response of dual structural systems that consisting of steel plate shear walls and moment‐resisting frames. The primary objective of the study was to investigate the influence of elastic base shear distribution between the wall and the frame on the global system response. A total of 10 walls and 30 wall–frame systems, ranging from 3 to 15 stories, were selected for numerical assessment. These systems represent cases in which the elastic base shear resisted by the frame has a share of 10, 25, or 50% of the total base shear resisted by the dual system. The numerical study consisted of 1600 time history analyses employing three‐dimensional finite elements. All 40 structures were separately analyzed for elastic and inelastic response by subjecting them to the selected suite of earthquake records. Interstory drifts, top story drift, base shears resisted by the wall, and the frame were collected during each analysis. Based on the analysis results, important response quantities, such as the strength reduction, the overstrength, and the displacement amplification factors, are evaluated herein. Results are presented in terms of displacement measures, such as the interstory drift ratio and the top story drift ratio. Analysis results revealed that the increase in the strength reduction factor with the amount of load share is insignificant. Furthermore, there is an inverse relationship between the ductility reduction and the overtsrength. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
The coupled steel plate shear wall (C-SPSW) configuration has been investigated by researchers as a means of improving the overturning stiffness and architectural flexibility of SPSW structures. While C-SPSWs have been shown to exhibit excellent seismic performance, the fabrication cost associated with the high number of moment-resisting connections used in such systems is a potential detraction to their use as an economical solution. Past research has shown that the hysteresis response of SPSWs with simple frame connections is significantly pinched, and as such, most seismic codes prohibit their use in high seismic areas. However, when used in the C-SPSW configuration, a dual system is formed in which the coupling beams not only improve resistance to overturning but also provide substantial lateral strength and energy dissipation capacity. This paper presents an exploration of the potential to improve the economy of C-SPSWs by using the simple boundary frame connections. First, employing the principles of plastic analysis, an attempt is made to quantify the contribution of the coupling beams to the overall lateral load resistance of the system. Then, to evaluate the seismic performance of such C-SPSW systems and allow for the comparison with that of the C-SPSWs with rigid frames, several prototypes are designed and analyzed using a series of nonlinear response history and pushover analyses. The results indicated that the C-SPSWs with simple boundary frames exhibited satisfactory seismic performance comparable with that of the C-SPSWs with rigid frames under both the 10/50 and 2/50 hazard levels, while allowing for reduced fabrication costs.  相似文献   

18.
The steel tube‐reinforced concrete (ST‐RC) composite column is a novel type of composite column, which consists of a steel tube embedded in RC. In this paper, the seismic behavior of ST‐RC columns is examined through a series of experiments in which 10 one‐third scale column specimens were subjected to axial forces and lateral cyclic loading. The test variables include the axial force ratio applied to the columns and the amount of transverse reinforcement. All specimens failed in a flexural mode, showing stable hysteresis loops. Thanks to the steel tube and the high‐strength concrete it is filled with, the ST‐RC column specimens had approximately 30% lower axial force ratios and 22% higher maximum bending moments relative to the comparable RC columns when subjected to identical axial compressive loads. The amount of transverse reinforcement made only a small difference to the lateral load‐carrying capacity but significantly affected the deformation and energy dissipation capacity of the ST‐RC columns. The specimens that satisfied the requirements for transverse reinforcement adopted for medium ductile RC columns as specified by the Chinese Code for Seismic Design of Buildings (GB 50011‐2010) and EuroCode 8 achieved an ultimate drift ratio of around 0.03 and a displacement ductility ratio of approximately 5. The design formulas used to evaluate the strength capacity of the ST‐RC columns were developed on the basis of the superposition method. The predictions from the formulas showed good agreement with the test results, with errors no greater than 10%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
Shaking table test results from a one‐story, two‐bay reinforced concrete frame sustaining shear and axial failures are compared with nonlinear dynamic analyses using models developed for the collapse assessment of older reinforced concrete buildings. The models provided reasonable estimates of the overall frame response and lateral strength degradation; however, the measured drifts were underestimated by the models. Selected model parameters were varied to investigate the sensitivity of the calculated response to changes in the drift at shear failure, rate of shear strength degradation, and drift at axial failure. For the selected ground motion, the drift at shear failure and rate of shear strength degradation did not have a significant impact on the calculated peak drift. By incorporating shear and axial‐load failure models, the analytical model is shown to be capable of predicting the axial‐load failure for a hypothetical frame with three nonductile columns. Improvements are needed in drift demand estimates from nonlinear dynamic analysis if such analyses are to be used in displacement‐based performance assessments. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
The corner gusset plates in a steel braced frame can be subjected to forces not only from the brace but also from the effects of the frame actions. In this study, several finite element models are constructed to analyze the gusset‐to‐beam and gusset‐to‐column interface forces. It is found that the frame actions affect the gusset interface force distributions significantly. A simplified strut model to represent the gusset plate is adopted to evaluate the frame action forces. In addition, the generalized uniform force method is adopted as it provides more freedom for designers to configure the gusset plate shapes than using the uniform force method. In this paper, a performance‐based design method is proposed. The gusset interface force demands take into account the combined effect of the brace maximum axial force capacity and the peak beam shear possibly developed in the frame. The specimen design and key results of a series of full‐scale three‐story buckling‐restrained braced frame (BRBF) hybrid tests are discussed. The gusset interface cracks observed at inter‐story drift greater than 0.03 radians can be well predicted by using the proposed design method. The BRBF tests and analyses confirm that the proposed design method is reasonable. The effectiveness of varying the width of gusset edge stiffeners in reducing the gusset tip stress concentrations is also investigated. This paper concludes with recommendations for the seismic design of BRBF corner gusset plates. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   