首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 440 毫秒
1.
Imaging in hard X-rays of any astrophysical source with high angular resolution is a challenging job. Shadow-casting technique is one of the most viable options for imaging in hard X-rays. We have used two different types of shadow-casters, namely, Coded Aperture Mask (CAM) and Fresnel Zone Plate (FZP) pair and two types of pixellated solid-state detectors, namely, CZT and CMOS in RT-2/CZT payload, the hard X-ray imaging instrument onboard the CORONAS-PHOTON satellite. In this paper, we present the results of simulations with different combinations of coders (CAM & FZP) and detectors that are employed in the RT-2/CZT payload. We discuss the possibility of detecting transient Solar flares with good angular resolution for various combinations. Simulated results are compared with laboratory experiments to verify the consistency of the designed configuration.  相似文献   

2.
The RT-2 Experiment onboard the CORONAS-PHOTON satellite is designed to study the spectral, temporal, and spatial details of solar hard X-ray flares in the 15–150 keV range. Above this energy (and upto 1000 keV), it also acts as an omni-directional gamma-ray detector with a capability to study gamma-ray bursts (GRB), bright solar flares, and X-ray pulsars. With an ensemble of hard X-ray detectors with different fields of view and coding devices, it also has the capability to investigate the spectrum of Cosmic Diffuse X-ray Background. The performance of the detectors from 2009 February to November is described in this paper. Results obtained on a few GRBs and solar flares are also briefly discussed.  相似文献   

3.
Phoswich detectors (RT-2/S & RT-2/G) are major scientific payloads of the RT-2 Experiment onboard the CORONAS-PHOTON mission, which was launched into a polar Low Earth Orbit of around 550 km on 2009 January 30. These RT-2 instruments are designed and developed to observe solar flares in hard X-rays and to understand the energy transport processes associated with these flares. Apart from this, these instruments are capable of observing Gamma Ray Bursts (GRBs) and Cosmic diffuse X-ray background (CDXRB). Both detectors consist of identical NaI(Tl) and CsI(Na) scintillation crystals in a Phoswich combination, having the same diameter (116 mm) but different thicknesses. The normal working energy range is from 15 keV to 150 keV, but may be extendable up to ~1 MeV. In this paper, we present the RT-2/S and RT-2/G instruments and discuss their testing and calibration results. We used different radio-active sources to calibrate both detectors. The radio-active source 57Co (122 keV) is used for onboard calibration of both instruments. During its lifetime (??3?C5 years), RT-2 is expected to cover the peak of the 24th solar cycle.  相似文献   

4.
Astrosat is the first Indian satellite mission dedicated for astronomical studies. It is planned for launch during 2014 and will have five instruments for multi-wavelength observations from optical to hard X-rays. Cadmium Zing Telluride Imager (CZTI) is one of the five instruments aiming for simultaneous X-ray spectroscopy and imaging in the energy range of 10 keV to 100 keV (along with all sky photometric capability unto 250 keV). It is based on pixilated CZT detector array with total geometric area of 1024 cm2. It will have two-dimensional coded mask for medium resolution X-ray imaging. The CZT detector plane will be realized using CZT detector modules having integrated readout electronics. Each CZT detector module consists of 4 cm × 4 cm CZT with thickness of 5 mm which is further pixilated into 16 × 16 array of pixels. Thus each pixel has size of 2.5 mm × 2.5 mm and thickness of 5 mm. Such pixilated detector plane can in principle be used for hard X-ray polarization measurements based on the principle of Compton scattering by measuring azimuthal distribution of simultaneous events in two adjacent pixels. We have carried out detailed Geant4 simulations for estimating polarimetric capabilities of CZTI detector plane. The results indicate that events in the energy range of 100 keV to 250 keV, where the 5 mm thick CZT detector has significant detection efficiency, can be used for polarimetric studies. Our simulation results indicate the minimum detectable polarization (MDP) at the level of ~ 10% can be achieved for bright Crab like X-ray sources with exposure time of ~500 ks. We also carried out preliminary experiments to verify the results from our simulations. Here we present detailed method and results of our simulations as well as preliminary results from the experimental verification of polarimetric capabilities of CZT detector modules used in Astrosat CZTI.  相似文献   

5.
Hard X-ray detectors in space are prone to background signals due to the ubiquitous cosmic rays and cosmic diffuse background radiation that continuously bombards the satellites which carry the detectors. In general, the background intensity depends on the space environment as well as the material surrounding the detectors. Understanding the behavior of the background noise in the detector is very important to extract the precise source information from the detector data. In this paper, we carry out Monte Carlo simulations using the GEANT-4 toolkit to estimate the prompt background noise measured with the detectors of the RT-2 Experiment onboard the CORONAS-PHOTON satellite.  相似文献   

6.
The Solar X-ray Spectrometer (SOXS) mission onboard GSAT-2 Indian Spacecraft was launched on 08 May 2003 using GSLV-D2 rocket by Indian Space Research Organization (ISRO). SOXS aims to study solar flares, which are the most violent and energetic phenomena in the solar system, in the energy range of 4–56 keV with high spectral and temporal resolution. SOXS employs state-of-the-art semiconductor devices, viz., Si-Pin and CZT detectors to achieve sub-keV energy resolution requirements. In this paper, we present an overview of data acquisition, control, communication and computation of low energy payload of the SOXS mission.  相似文献   

7.
We present the first results from the low-energy detector payload of the solar X-ray spectrometer (SOXS) mission, which was launched onboard the GSAT-2 Indian spacecraft on May 08, 2003 by the GSLV-D2 rocket to study solar flares. The SOXS low-energy detector (SLD) payload was designed, developed, and fabricated by the Physical Research Laboratory (PRL) in collaboration with the Space Application Centre (SAC), Ahmedabad and the Indian Space Research Organization (ISRO) Satellite Centre (ISAC), Bangalore. The SLD payload employs state-of-the-art, solid-state detectors, viz., Si PIN and Cadmium-Zinc-Telluride (CZT) devices that operate at near room temperature (−20 °C). The energy ranges of the Si PIN and CZT detectors are 4 – 25 and 4 – 56 keV, respectively. The Si PIN provides sub-keV energy resolution, while the CZT provides ~1.7 keV energy resolution throughout the energy range. The high sensitivity and sub-keV energy resolution of the Si PIN detector allows measuring the intensity, peak energy, and the equivalent width of the Fe-line complex at approximately 6.7 keV, as a function of time in all ten M-class flares studied in this investigation. The peak energy (E p) of the Fe-line feature varies between 6.4 and 6.7 keV with increase in temperature from 9 to 58 MK. We found that the equivalent width (w) of the Fe-line feature increases exponentially with temperature up to 30 MK and then increases very slowly up to 40 MK. It remains between 3.5 and 4 keV in the temperature range of 30 – 45 MK. We compare our measurements of w with calculations made earlier by various investigators and propose that these measurements may improve theoretical models. We interpret the variation of both E p and w with temperature as being to the changes in the ionization and recombination conditions in the plasma during the flare, and as a consequence, the contribution from different ionic emission lines also varies.  相似文献   

8.
The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X- γ space observatory. It consisted of two identical soft X-ray (0.3–10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera Astronomical Observatory where they had been manufactured. After 16 years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel Detector (GPD) with polarimetric capabilities in the focal plane of the FM2. The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In the first phase of the test campaign, we have re-tested the FM2 at PANTER to have an up-to-date characterization in terms of angular resolution and effective area, while in the second part of the test the GPD has been placed in the focal plane of the FM2. In this paper we report the results of the tests of the sole FM2, using an unpolarized X-ray source, comparing the results with the calibration done in 1996.  相似文献   

9.
Basic principles of operation and characteristics of scintillation and semi-conductor detectors used for solar hard X-ray and gamma-ray spectrometers are presented. Scintillation materials such as NaI offer high stopping power for incident gamma rays, modest energy resolution, and relatively simple operation. They are, to date, the most often used detector in solar gamma-ray spectroscopy. The scintillator BGO has higher stopping power than NaI, but poorer energy resolution. The primary advantage of semi-conductor materials such as Ge is their high-energy resolution. Monte-Carlo simulations of the response of NaI and Ge detectors to model solar flare inputs show the benefit of high resolution for studying spectral lines. No semi-conductor material besides Ge is currently available with adequate combined size and purity to make general-use hard X-ray and gamma-ray detectors for solar studies.  相似文献   

10.
We present the first results from the ‘Low Energy Detector’ pay-load of ‘Solar X-ray Spectrometer (SOXS)’ mission, which was launched onboard GSAT-2 Indian spacecraft on 08 May 2003 by GSLV-D2 rocket to study the solar flares. The SOXS Low Energy Detector (SLD) payload was designed, developed and fabricated by Physical Research Laboratory (PRL) in collaboration with Space Application Centre (SAC), Ahmedabad and ISRO Satellite Centre (ISAC), Bangalore of the Indian Space Research Organization (ISRO). The SLD payload employs the state-of-the-art solid state detectors viz., Si PIN and Cadmium-Zinc-Telluride (CZT) devices that operate at near room temperature (-20°C). The dynamic energy range of Si PIN and CZT detectors are 4–25 keV and 4–56 keV respectively. The Si PIN provides sub-keV energy resolution while CZT reveals ∼1.7keV energy resolution throughout the dynamic range. The high sensitivity and sub-keV energy resolution of Si PIN detector allows the measuring of the intensity, peak energy and equivalent width of the Fe-line complex at approximately 6.7 keV as a function of time in all 8 M-class flares studied in this investigation. The peak energy (E p) of Fe-line feature varies between 6.4 and 6.8 keV with increase in temperature from 9 to 34 MK. We found that the equivalent width (ω) of Fe-line feature increases exponentially with temperature up to 20 MK but later it increases very slowly up to 28 MK and then it remains uniform around 1.55 keV up to 34 MK. We compare our measurements ofw with calculations made earlier by various investigators and propose that these measurements may improve theoretical models. We interpret the variation of both Epand ω with temperature as the changes in the ionization and recombination conditions in the plasma during the flare interval and as a consequence the contribution from different ionic emission lines also varies.  相似文献   

11.
We have evaluated several solid state detectors which offer excellent energy resolution at room temperature for soft X-rays. For soft X-rays (< 1 keV to 20 keV), silicon P-intrinsic-N (PIN) and avalanche-mode photodiodes (APD's) have been studied. Using commercially available charge sensitive pre-amplifiers, these photodiodes provide 1 keV resolution without cooling. Their detection efficiencies are limited to about 20 keV and 15 keV, respectively. To overcome this constraint, we have studied thick (1.5 mm) PIN detectors made by Micron Semiconductor Ltd., U.K., as well as compound semiconducting materials with high Z constituents such as CZT and PbI2. PbI2 allows high detection efficiencies of photons up to 100 keV with detectors 100–300 microns thick. These new detectors offer the capability to study the low-energy spectral evolution of Gamma ray bursts (GRBs). A matrix of these detectors could be used as an image plane detector with moderate spatial resolution for imaging.  相似文献   

12.
The hard X-ray imaging telescope based on the Fourier transform imaging technique is introduced. The double-layer parallel gratings are used to make the modulation and coding on the light emerging from a celestial X-ray source, the modulated light is acquired, to make the optoelectronic conversion by scintillation crystal detectors, and ?nally read out by the electronic system. The modulation collimator X-ray telescopes can be divided into two types: the spatial modulation and temporal modulation. The temporal modulation system requires the scanning motion of the detector system, but the spatial modulation system requires no motion. The technology of grating fabrication is investigated, and the basic structure design of the collimators is given. The principal compo- nents of the prototype hard X-ray imaging telescope of spatial modulation type are successfully developed, including the 8 CsI crystal detector modules (contain- ing photomultipliers or PMTs), 8-channel shaping ampli?ers (two of them are prepared for experiments), and the data acquisition system. And the preliminary test results of the electronic system are also given.  相似文献   

13.
Lin  R. P.  Curtis  D. W.  Primbsch  J. H.  Harvey  P. R.  Levedahl  W. K.  Smith  D. M.  Pelling  R. M.  Duttweiler  F.  Hurley  K. 《Solar physics》1987,113(1-2):333-345

We describe a balloon payload designed to study the processes of energy release, particle acceleration, and heating of the active corona, in hard X-ray microflares and normal flares. An array of liquid nitrogen-cooled germanium detectors together with large area phoswich scintillation detectors provide the highest sensitivity (∼500 cm2) and energy resolution (≤0.7 keV) ever achieved for solar hard X-ray (∼15–600 keV) measurements. These detectors were flown in February 1987 from Australia on a long duration RAdiation COntrolled balloON (RACOON) flight (LDBF) which provided 12 days of observations before cutdown in Brazil. The payload includes solar cells for power, pointing and navigation sensors, a microprocessor controlled data system with VCR tape storage, and transmitters for GOES and ARGOS spacecraft. This successful flight illustrates the potential of LDBF's for solar flare studies.

  相似文献   

14.
Solid state detectors are used in x-ray and gamma-ray astronomy primarily for their fine spectroscopy. For some cases (e.g., gamma-ray observations with Ge detectors), the spectroscopy and sensitivity requirements drive the design of the aperture systems and only moderate-quality imaging is possible. In other cases (e.g., hard x-ray observations), the detectors can be finely segmented for highquality imaging. The new room-temperature solid-state detectors like CdZnTe and HgI2 are naturally well-suited for imaging. Because of their high atomic numbers, photoelectric absorption dominates over Compton scattering to >200 keV. This, combined with their high densities, allows thin detectors to be used with segmented contacts. Position resolution in the detector plane can be on 100 m scales giving sub-arcmin angular resolutions.  相似文献   

15.
The onboard software and data communication in the RT-2 Experiment onboard the Coronas?CPhoton satellite is organized in a hierarchical way to effectively handle and communicate asynchronous data generated by the X-ray detectors. A flexible data handling system is organized in the X-ray detector packages themselves and the processing electronic device, namely RT-2/E, has the necessary intelligence to communicate with the three scientific payloads by issuing commands and receiving data. It has direct interfacing with the Satellite systems and issues commands to the detectors and processes the detector data before sending to the satellite systems. The onboard software is configured with several novel features like (a) device independent communication scheme, (b) loss-less data compression and (c) Digital Signal Processor. Functionality of the onboard software along with the data structure, command structure, complex processing scheme etc. are discussed in this paper.  相似文献   

16.
The first space-borne solar astronomy experiment of India, namely Solar X-ray Spectrometer (SOXS), was successfully launched on 08 May 2003 on board geostationary satellite GSAT-2 of India. The SOXS is composed of two independent payloads, viz. SOXS Low-Energy Detector (SLD) Payload and SOXS High-Energy Detector (SHD) Payload. The SOXS aims to study the full-disk integrated X-ray emission in the energy range from 4 keV to 10 MeV. In this paper we present the first report on the SLD instrumentation and its in-orbit performance. The SLD payload was designed and developed at the Physical Research Laboratory in collaboration with various centers of Indian Space Research Organisation (ISRO). The basic scientific aim of the SLD payload is to study solar flares in the energy range from 4 to 60 keV with high spectral and temporal resolution. To meet these requirements, the SLD payload employs state-of-the-art solid state detectors, the first time for a solar astronomy experiment, viz. Si PIN (4 –25 keV), and cadmium–zinc–telluride (4 –60 keV). With their superb high-energy resolution characteristics, SLD can observe iron and iron–nickel complex lines that are visible only during solar flares. In view of its 3.4 FOV, the detector package is mounted on a Sun Aspect System, for the first time, to get uninterrupted observations in a geostationary orbit. The SLD payload configuration, its in-flight operation, and the response of the detectors are presented. We also present the first observations of solar flares made by the SLD payload and briefly describe their temporal and spectral mode results.  相似文献   

17.
磁场是太阳物理的第1观测量,当前太阳磁场观测研究正迈向大视场、高时空分辨率、高偏振测量精度以及空间观测的时代.中国首颗太阳观测卫星—先进天基太阳天文台(ASO-S)也配置了具有高时空分辨率、高磁场灵敏度的全日面矢量磁像仪(FMG)载荷,针对FMG载荷的需求,讨论了大面阵、高帧频互补金属氧化物半导体(Complementary Metal Oxide Semiconductor, CMOS)图像传感器应用于太阳磁场观测的可行性.首先,基于滤光器型太阳磁像仪观测的原理,比较分析了目前CMOS图像传感器(可用的或是可选的两种快门模式)的特点,指出全局快门类型更适合FMG;其次搭建了CMOS传感器实验室测试系统,测量了CMOS图像传感器的像素增益及其分布规律;最后在怀柔太阳观测基地的全日面太阳望远镜上开展了实测验证,获得预期成果.在这些研究基础上,形成了FMG载荷探测器选型方向.  相似文献   

18.
We describe a balloon payload designed to study the processes of energy release, particle acceleration, and heating of the active corona, in hard X-ray microflares and normal flares. An array of liquid nitrogen-cooled germanium detectors together with large area phoswich scintillation detectors provide the highest sensitivity (500 cm2) and energy resolution (0.7 keV) ever achieved for solar hard X-ray (15–600 keV) measurements. These detectors were flown in February 1987 from Australia on a long duration RAdiation COntrolled balloON (RACOON) flight (LDBF) which provided 12 days of observations before cutdown in Brazil. The payload includes solar cells for power, pointing and navigation sensors, a microprocessor controlled data system with VCR tape storage, and transmitters for GOES and ARGOS spacecraft. This successful flight illustrates the potential of LDBF's for solar flare studies.Also Physics Department.Presently at Space Sciences Laboratory, University of California, Berkeley CA 94720.  相似文献   

19.
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and γ-ray detection. However, a considerable amount of charge loss in these detectors results in a reduced energy resolution. We have achieved a significant improvement in the spectral properties by forming the Schottky junction on the Te side of the CdTe wafer. With the further reduction of leakage current by an adoption of guard ring structure, we have demonstrated a CdTe pixel detector with high energy resolution and full charge collection capabilty. The detector has a pixel size of a few mm and a thickness of 0.5 $-$ 1 mm. We apply this high resolution detector to a new silicon and CdTe Compton Camera which features high angular resolution. We also describe a concept of the stack detector which consists of many thin CdTe layers and provides sufficient efficiency for hard X-rays and gamma-rays up to several hundred keV maintaining good energy resolution. A narrow-FOV Compton telescope can be realized by installing a Si/CdTe Compton Camera inside the deep well of an active shield. This configuration is very suitable as focal plane detector for future focusing gamma-ray missions.  相似文献   

20.
The Mercury Imaging X-ray Spectrometer (MIXS) will be launched on board of the 5th ESA cornerstone mission BepiColombo. The two channel instrument MIXS is dedicated to the exploration of the elemental composition of the mercurian surface by imaging x-ray spectroscopy of the elemental fluorescence lines. One of the main scientific goals of MIXS is to provide spatially resolved elemental abundance maps of key rock-forming elements. MIXS will be the successor of the XRS instrument, which is currently orbiting Mercury on board of NASAs satellite MESSENGER. MIXS will provide unprecedented spectral and spatial resolution due to its innovative detector and optics concepts. The MIXS target energy band ranges from 0.5 to 7 keV and allows to directly access the Fe-L line at 0.7 keV, which was not accessible to previous missions. In addition, the high spectroscopic resolution of FWHM ≤ 200 eV at the reference energy of 1 keV after one year in Mercury orbit, allows to separate the x-ray fluorescence emission lines of important elements like Mg (1.25 keV) and Al (1.49 keV) without the need for any filter. The detectors for the energy and spatially resolved detection of x-rays for both channels are identical DEPFET (DEpleted P-channel FET) active pixel detectors. We report on the calibration of the MIXS flight and flight spare detector modules at the PTB (Physikalisch-Technische Bundesanstalt) beamlines at the BESSY II synchrotron radiation facility. Each detector was calibrated at least at 10 discrete energies in the energy range from 0.5 to 10 keV. The excellent spectroscopic performance of all three detector modules was verified.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号