首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 34 毫秒
1.
Viscoelastic–plastic (VEP) dampers are hybrid passive damping devices that combine the advantages of viscoelastic and hysteretic damping. This paper first formulates a semi‐analytical procedure for predicting the peak response of nonlinear SDOF systems equipped with VEP dampers, which forms the basis for the generation of Performance Spectra that can then be used for direct performance assessment and optimization of VEP damped structures. This procedure is first verified against extensive nonlinear time‐history analyses based on a Kelvin viscoelastic model of the dampers, and then against a more advanced evolutionary model that is calibrated to characterization tests of VEP damper specimens built from commercially available viscoelastic damping devices, and an adjustable friction device. The results show that the proposed procedure is sufficiently accurate for predicting the response of VEP systems without iterative dynamic analysis for preliminary design purposes. A design method based on the Performance Spectra framework is then proposed for systems equipped with passive VEP dampers and is applied to enhance the seismic response of a six‐storey steel moment frame. The numerical simulation results on the damped structure confirm the use of the Performance Spectra as a convenient and accurate platform for the optimization of VEP systems, particularly during the initial design stage. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
3.
The determination of displacement demands for masonry buildings subjected to seismic action is a key issue in the performance-based assessment and design of such structures. A technique for the definition of single-degree-of-freedom (SDOF) nonlinear systems that approximates the global behaviour of multi-degree-of-freedom (MDOF) 3D structural models has been developed in order to provide useful information on the dependency of displacement demand on different seismic intensity measures. The definition of SDOF system properties is based on the dynamic equivalence of the elastic properties (vibration period and viscous damping) and on the comparability with nonlinear hysteretic behaviour obtained by cyclic pushover analysis on MDOF models. The MDOF systems are based on a nonlinear macroelement model that is able to reproduce the in-plane shear and flexural cyclic behaviour of pier and spandrel elements. For the complete MDOF models an equivalent frame modelling technique was used. The equivalent SDOF system was modelled using a suitable nonlinear spring comprised of two macroelements in parallel. This allows for a simple calibration of the hysteretic response of the SDOF by suitably proportioning the contributions of flexure-dominated and shear-dominated responses. The comparison of results in terms of maximum displacements obtained for the SDOF and MDOF systems demonstrates the feasibility and reliability of the proposed approach. The comparisons between MDOF and equivalent SDOF systems, carried out for several building prototypes, were based on the results of time-history analyses performed with a large database of natural records covering a wide range of magnitude, distance and local soil conditions. The use of unscaled natural accelerograms allowed the displacement demand to be expressed as a function of different ground motion parameters allowing for the study of their relative influence on the displacement demand for masonry structures.  相似文献   

4.
刘宗成    韩建平   《世界地震工程》2022,38(2):141-150
消能减震结构中主体结构和附加消能减震装置通常是单独设计的,由于主体结构和附加消能减震装置之间的耦合特性,为实现期望的性能目标需要进行迭代计算。本文提出一种基于位移的主体结构与附加消能减震装置一体化设计方法,首先,基于所选地震动记录和预期性能目标,得出结构阻尼比需求曲面;其次,推导了阻尼器-支撑部件参数计算公式,在已知主体结构基本信息及预期性能目标时,根据阻尼比需求曲面及所提出公式即可获得所需附加消能减震装置的支撑刚度及粘滞系数;再次,引入无量纲成本指数,以成本指数最小为目标函数,在可实现目标性能的附加消能减震装置参数中识别最优设计参数;最后,基于所提出的设计方法,分别以等效SDOF体系、MDOF体系及SAP2000设计的6层RC框架结构为例,对所提出的设计方法的有效性进行了验证,结果表明:经一体化设计的结构体系均可实现性能目标。  相似文献   

5.
During severe seismic events, structures designed according to current standards yield and develop inelastic deformations. While the acceleration responses are limited by the yielding strength, these structures develop permanent deformations (and possible damage) due to such yielding. Spectra developed for inelastic structures can help in determining the desired yield levels and the associated inelastic deformations. Some structures made of special materials or equipped with innovative structural systems may yield, but can recover the deformation upon unloading and, thus, may avoid permanent deformations. These structures are known as nonlinear elastic. Often the post yielding excursions are very large and may exceed their toughness (or deformability). By introducing damping in form of supplemental devices, it is possible to control such deformations and keep them within acceptable limits. Spectra for such nonlinear elastic structures and inelastic structures are developed herein, by considering both inherent and supplemental damping. The difference between the two types of damping is addressed both theoretically and numerically. Design examples of several simple structures using the newly developed spectra are presented, which illustrate the importance of lower strength and damping in these nonlinear elastic or inelastic systems. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
Passive structural control techniques are generally used as seismic rehabilitation and retrofit methodologies for existing structures. A poorly explored and exciting opportunity within structural seismic control research is represented by the possibility to design new structural forms and configurations, such as slender buildings, without compromising the structural performance through an integrated design approach. In this paper, with reference to viscous dampers, an integrated seismic design procedure of the elastic stiffness resources and viscoelastic properties of a dissipative bracing‐damper system is proposed and developed to ensure a seismic design performance, within the displacement‐based seismic design, explicitly taking into account the dynamic behaviour both of the structural and control systems. The optimal integrated seismic design is defined as the combination of the variables that minimizes a suitable index, representing an optimized objective function. Numerical examples of the proposed integrated cost‐effectiveness seismic design approach both on an equivalent SDOF system and a proportionally damped MDOF integrated system are developed defining the design variables, which minimize the cost index. Validation of the effectiveness of the proposed integrated design procedure is carried out by evaluating the average displacement of the time‐history responses to seven unscaled acceleration records selected according to EC8 provisions. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
The seismic performance of existing structures can be assessed based on nonlinear static procedures, such as the Capacity Spectrum Method. This method essentially approximates peak responses of an inelastic single‐degree‐of‐freedom (SDOF) system using peak responses of an equivalent linear SDOF model. In this study, the equivalent linear models of inelastic SDOF systems are developed based on the constant strength approach, which does not require iteration for assessing the seismic performance of existing structures. To investigate the effects of earthquake type and seismic region on the equivalent linear models, four ground‐motion data sets—Japanese crustal/interface/inslab records and California crustal records—are compiled and used for nonlinear dynamic analysis. The analysis results indicate that: (1) the optimal equivalent linear model parameters (i.e. equivalent vibration period ratio and damping ratio) decrease with the natural vibration period, whereas they increase with the strength reduction factor; (2) the impacts of earthquake type and seismic region on the equivalent linear model parameters are not significant except for short vibration periods; and (3) the degradation and pinching effects affect the equivalent linear model parameters. We develop prediction equations for the optimal equivalent linear model parameters based on nonlinear least‐squares fitting, which improve and extend the current nonlinear static procedure for existing structures with degradation and pinching behavior. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
延性需求谱在基于性能的抗震设计中的应用   总被引:23,自引:4,他引:19  
基于性能的抗震设计理论涉及如何简便而合理地确定结构在指定强度地震下的弹塑性位移需求。本文给出了利用延性需求谱求解结构位移需求的一般步骤:借助模态Pushover分析将多自由度体系分解为几个非线性单自由度体系,以考虑各阶振型的影响;利用延性需求谱计算对应模态的等效单自由度体系的延性及位移需求,并以一定方式组合转化为多自由度体系位移需求。最后,通过算例分析表明:利用延性需求谱求解结构位移需求是一种具有一定精度可为工程接受的简便方法,在基于性能的抗震设计中具有较好的应用前景。  相似文献   

10.
A methodology for the development of design tools for direct estimation of peak inelastic response in reduced-degree-of-freedom (RDOF) isolation and energy dissipation systems is presented. The suggested procedure is an extension of an earlier method addressing purely hysteretic isolation systems. Herein, the dynamic equation of motion is first normalised to reduce the number of design parameters that significantly affect the response. The sensitivity of normalised response quantities to the amplitude of the ground motion is then investigated through extensive parametric nonlinear dynamic analyses of isolated single-degree-of-freedom (SDOF) systems with linear viscous damping using code-based target spectra. Regression analysis is subsequently employed to develop generalised design equations (GDEs) suitable for design. Further investigations are made to address nonlinear viscous damping and the effect of the transverse component of seismic action in two-degree-of freedom (2DOF) systems under bidirectional excitation, making the procedure applicable to common bridge isolation schemes. GDEs constitute an alternative to equivalent linearisation approaches commonly adopted by codes, informing the selection among alternative isolation and energy dissipations schemes without requiring iterative analysis. The approach is incorporated in the Deformation-Based Design methodology for seismically isolated bridges in a forthcoming paper.  相似文献   

11.
Existing design procedures for determining the separation distance between adjacent buildings subjected to seismic pounding risk are based on approximations of the buildings' peak relative displacement. These procedures are characterized by unknown safety levels and thus are not suitable for use within a performance‐based earthquake engineering framework. This paper introduces an innovative reliability‐based methodology for the design of the separation distance between adjacent buildings. The proposed methodology, which is naturally integrated into modern performance‐based design procedures, provides the value of the separation distance corresponding to a target probability of pounding during the design life of the buildings. It recasts the inverse reliability problem of the determination of the design separation distance as a zero‐finding problem and involves the use of analytical techniques in order to evaluate the statistics of the dynamic response of the buildings. Both uncertainty in the seismic intensity and record‐to‐record variability are taken into account. The proposed methodology is applied to several different buildings modeled as linear elastic single‐degree‐of‐freedom (SDOF) and multi‐degree‐of‐freedom (MDOF) systems, as well as SDOF nonlinear hysteretic systems. The design separation distances obtained are compared with the corresponding estimates that are based on several response combination rules suggested in the seismic design codes and in the literature. In contrast to current seismic code design procedures, the newly proposed methodology provides consistent safety levels for different building properties and different seismic hazard conditions. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
In this paper, a method for designing supplemental brace–damper systems in single‐degree‐of‐freedom (SDOF) structures is presented. We include the effects of the supporting brace stiffness in the dynamic response by using a viscoelastic Maxwell model. On the basis of the study of an SDOF under ground excitation, we propose a noniterative design procedure for simultaneously specifying both the damper and the brace while assuring a desired structural performance. It is shown that to increase the damper size beyond the value delivered by the proposed criteria will not provide any improvement but actually worsen the structural response. The design method presented here shows excellent agreement with the FEMA 273 design approach but offers solutions closer to optimality. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
Hysteretic energy dissipation in a structure during an earthquake is the key factor, besides maximum displacement, related to the amount of damage in it. This energy demand can be accurately computed only through a nonlinear time‐history analysis of the structure subjected to a specific earthquake ground acceleration. However, for multi‐story structures, which are usually modeled as multi‐degree of freedom (MDOF) systems, this analysis becomes computation intensive and time consuming and is not suitable for adopting in seismic design guidelines. An alternative method of estimating hysteretic energy demand on MDOF systems is presented here. The proposed method uses multiple ‘generalized’ or ‘equivalent’ single degree of freedom (ESDOF) systems to estimate hysteretic energy demand on an MDOF system within the context of a ‘modal pushover analysis’. This is a modified version of a previous procedure using a single ESDOF system. Efficiency of the proposed procedure is tested by comparing energy demands based on this method with results from nonlinear dynamic analyses of MDOF systems, as well as estimates based on the previous method, for several ground motion scenarios. Three steel moment frame structures, of 3‐, 9‐, and 20‐story configurations, are selected for this comparison. Bias statistics that show the effectiveness of the proposed method are presented. In addition to being less demanding on the computation time and complexity, the proposed method is also suitable for adopting in design guidelines, as it can use response spectra for hysteretic energy demand estimation. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
This note is an extension of earlier works that presented probability distribution functions for amplitudes of the peaks (the highest, the second highest … the m-th highest) in response of deterministic single degree-of-freedom (SDOF) and multi degree-of-freedom (MDOF) structures to ground motion, with deterministic Fourier spectrum and duration. It shows how these probability distribution functions can be evaluated if the Fourier spectrum and duration of the excitation are random variables specified via distribution functions. Two cases are considered: (l) when the structural model is deterministic, and (2) when the modal frequencies are random variables. The procedure presented here approximates the transfer function of the structural response by Dirac delta functions at the modal frequencies, and is applicable to multi-storey buildings with small modal damping, and with natural frequencies that are not too close. The resulting probability distribution functions are needed in seismic hazard calculations of peak response amplitudes of SDOF and MDOF structures that will not be exceeded with given confidence during the service time of the structure from any earthquake at all known faults within certain distance from the structure.  相似文献   

15.
The concept of displacement-based design is attractive for seismic design, primarily because it places the focus of design directly on displacement demand, and hence damage, rather than on force-reduction or behaviour factors. A procedure is presented which extends the simple concept of displacement-based design to complex multi-degree-of-freedom (MDOF) bridge structures. The procedure is based on the assumption of a displaced shape for the structure, and the subsequent reduction of the system to an equivalent single-degree-of-freedom (SDOF) system. The process is shown to work well for the design of a symmetrical bridge, while suffering some shortcomings when applied to a highly irregular bridge. The topic of design-oriented displacement response spectra is also briefly addressed.  相似文献   

16.
The primary purpose of this research is to improve the seismic response of a complex asymmetric tall structure using viscoelastic(VE) dampers. Asymmetric structures have detrimental effects on the seismic performance because such structures create abrupt changes in the stiffness or strength that may lead to undesirable stress concentrations at weak locations. Structural control devices are one of the effective ways to reduce seismic impacts, particularly in asymmetric structures. For passive vibration control of structures, VE dampers are considered among the most preferred devices for energy dissipation. Therefore, in this research, VE dampers are implemented at strategic locations in a realistic case study structure to increase the level of distributed damping without occupying significant architectural space and reducing earthquake vibrations in terms of story displacements(drifts) and other design forces. It has been concluded that the seismic response of the considered structure retrofitted with supplemental VE dampers corresponded well in controlling the displacement demands. Moreover, it has been demonstrated that seismic response in terms of interstory drifts was effectively mitigated with supplemental damping when added up to a certain level. Exceeding the supplemental damping from this level did not contribute to additional mitigation of the seismic response of the considered structure. In addition, it was found that the supplemental damping increased the total acceleration of the considered structure at all floor levels, which indicates that for irregular tall structures of this type, VE dampers were only a good retrofitting measure for earthquake induced interstory deformations and their use may not be suitable for acceleration sensitive structures. Overall, the research findings demonstrate how seismic hazards to these types of structures can be reduced by introducing additional damping into the structure.  相似文献   

17.
The energy approach is used to theoretically verify that the average acceleration method (AAM), which is unconditionally stable for linear dynamic systems, is also unconditionally stable for structures with typical nonlinear damping, including the special case of velocity power type damping with a bilinear restoring force model. Based on the energy approach, the stability of the AAM is proven for SDOF structures using the mathematical features of the velocity power function and for MDOF structures by applying the virtual displacement theorem. Finally, numerical examples are given to demonstrate the accuracy of the theoretical analysis.  相似文献   

18.
The seismic performance of Tuned Liquid Column Dampers (TLCDs) for the passive control of flexible structures is investigated using random vibration analysis. A non-stationary stochastic process with frequency and amplitude modulation is used to represent the earthquake strong motion, and a simple equivalent linearization technique is used to account for the non-linear damping force in the TLCD. The governing equations of motion for the structure TLCD system are formulated and reduced to a first-order state vector equation, from which the differential equation for the system response covariance matrix is obtained. The TLCD performance is evaluated on the basis of selected structural response statistics, namely, the expected maximum and root-mean-square displacements, and root-mean-square absolute accelerations and interstorey shears. A parametric study and sensitivity analysis are conducted to assess the TLCD performance and identify critical design parameters. Illustrative examples are presented using SDOF and MDOF shear-beam structural models, a wide-banded stationary random base acceleration and two non-stationary random input ground motions representative of long- and short-duration ground accelerations with significant low-frequency content.  相似文献   

19.
工程结构等延性地震抗力谱研究   总被引:28,自引:7,他引:21  
研究结构的非弹性反应谱对改进现有的结构抗震设计、发展基于性态的抗震设计以及了解复杂地面运动特性与结构动力特性之间的关系具有重要的意义。利用大量的单自由度在强震记录作用下的弹塑性动力时程分析,对等延性地震抗力谱这一重要的非弹性反应谱进行了较为详尽的研究,给出了四类场地条件(基岩、硬土、一般土和软土)下的平均等延性地震抗力谱,总结了对工程结构的抗震设计和研究具有实际意义的规律和特征,并分析了场地条件、结构的延性系数以及周期等对等延性地震抗力谱的影响,提出了新的拟合公式,其成果可供抗震研究和设计直接应用。  相似文献   

20.
结构附加粘滞阻尼器的抗震设计   总被引:2,自引:0,他引:2  
本文结合抗震设计规范反应谱,给出了一个附加非线性流体粘滞阻尼器结构的抗震设计方法。研究了非线性阻尼器的力学特性,引入了非线性流体阻尼器的等效线性阻尼比,给出了计算最大加速度时刻附加非线性流体阻尼器结构反应的荷载组合系数,提出了按阻尼力的水平力分量与楼层剪力成正比的原则分配阻尼器阻尼系数的方法。同时给出了基于抗震规范设计反应谱附加非线性阻尼器结构的设计流程,通过一个算例说明了使用该方法设计附加非线性粘滞阻尼器结构的全过程。算例分析表明,这种设计方法适合于手算,便于设计人员掌握,在初步设计阶段可以快速、有效地设计满足给定性能水平的附加非线性流体阻尼器体系。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏