首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 52 毫秒
1.
Six cyclic tests were conducted on three full‐scale subassemblies to investigate the behavior of interior beam‐to‐column post‐tensioned (PT) connections. Strands were placed along each side of the steel beam web, passing through the steel column to provide precompression between the beams and a column. Top and bottom energy‐dissipating (ED) bars, passing through the column and welded to the beam, were used to increase the moment capacity and ED capacity of the connection. One of the subassemblies also had a composite concrete slab with discontinuity at the column centerline to eliminate restraint from the metal deck, reinforcement, and welded wire mesh. The objectives of this paper were to investigate the following: the durability of the connection by loading each specimen twice, the ED capacity of the ED bar, and the effects that the type of ED bar and type of composite slab have on the self‐centering behavior of the connection. The experimental results showed that: (1) the connection could sustain severe inelastic cyclic loading at least twice without strength degradation, (2) the ED capacity of the bar was much larger than that dissipated by a single AISC loading protocol, and (3) a specimen with a discontinuous composite slab, which opened freely at the centerline of the column, ensured the same self‐centering hysteretic behavior as the bare steel specimen. However, the decompression moment of the PT connection decreased significantly at each interstory drift, resulting in an early opening of a gap at the beam–column interface. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
下翼缘摩擦式自定心钢框架梁柱节点抗震性能的数值模拟   总被引:2,自引:0,他引:2  
宋良龙  郭彤 《地震学刊》2011,(6):648-653
介绍了一种新型的铜框架梁柱节点形式,其中预应力钢绞线提供了结构在地震作用下的复位功能(自定心),设置在梁端下翼缘的摩擦件则为结构提供了耗能能力;介绍了下翼缘摩擦式自定心钢框架粱柱节点的构造和工作原理,以节点的低用反复加载试验结果为依据,利用面向对象的开放式计算程序OpenSees建立了节点的数值模型,并侧重于模拟节点在地震作用下的张开/闭合、自定心、摩擦耗能以及螺栓受剪等特性。由计算结果与试验结果对比可知,所建立的数值模型对节点的抗震性能具有良好的模拟效果。  相似文献   

3.
通过柱端加载的低周反复荷载试验对8个内隔板三边焊接,而在未焊一边柱壁板上布置圆柱头栓钉的方钢管混凝土柱-H形钢梁节点进行了试验研究,研究了不同轴压比情况下节点的破坏模式、延性、耗能性能等。试验结果表明,破坏之前节点具有良好的滞回性能、延性及耗能能力,满足现行抗震规范的要求。该节点可以用于方钢管混凝土柱两侧弯矩相差较大时,弯矩较小一侧节点。提出了相关的设计建议。  相似文献   

4.
This paper first presents the force–deformation relationship of a post‐tensioned (PT) steel beam‐to‐column connection constructed with bolted web friction devices (FDs). This paper then describes the test program conducted in the National Center for Research on Earthquake Engineering, Taiwan, on four bolted FDs and four full‐scale PT beam‐to‐column moment connection subassemblies using the FDs. Tests confirm that (1) the hysteretic behavior of four bolted FDs is very stable, (2) the friction coefficient between the steel plate and the brass shim is about 0.34, (3) the proposed force–deformation relationships reasonably predict the experimental responses of the PT connections under cyclically increasing deformations up to a beam peak rotation of 0.05 rad, and (4) the decompression moments do not degrade as beam cyclic deformations increase. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

5.
A new type of steel moment resisting frame with bottom ? ange friction devices (BFFDs) has been developed to provide self-centering capacity and energy dissipation, and to reduce permanent deformations under earthquakes. This paper presents a numerical simulation of self-centering beam-column connections with BFFDs, in which the gap opening /closing at the beam-column interfaces is simulated by using pairs of zero-length elements with compression-only material properties, and the energy dissipation due to f...  相似文献   

6.
本文进行了2种矩形钢管混凝土柱与钢梁连接节点——翼缘全螺栓(BFP)连接节点与外加强环(WFP-BW)连接节点在柱端低周反复荷载作用下的抗震性能试验,分析比较了这2类节点与焊接翼缘板(WFP)连接节点在不同轴压比下的滞回性能、强度与刚度退化、延性比与耗能比、破坏机理与破坏特征,得出了一些有参考价值的结论。  相似文献   

7.
The seismic performance of post‐tensioned steel connections for moment‐resisting frames was examined experimentally and analytically. Cyclic tests were conducted on three full‐scale subassemblies, which had two steel beams post‐tensioned to a concrete‐filled tube (CFT) column with high‐strength strands to provide recentring response. Reduced flange plates (RFPs) welded to the column and bolted to the beam flange were used to increase the dissipation of energy. Test results indicated that (1) the proposed buckling‐restrained RFP could dissipate energy in axial tension and compression, (2) the subassemblies could reach an interstorey drift of 4% without strength degradation, and (3) buckling of the beam occurred towards an interstorey drift of 5%, causing a loss of the strand force, the recentring response, and the moment capacity. A general‐purpose non‐linear finite element analysis program (ABAQUS) was used to perform a correlation study. The behaviour of the steel beam under both post‐tensioning and flexural loadings was compared to the test results and predictions. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

8.
The self‐centering prestressed concrete (SCPC) moment resisting frame (MRF) with web friction devices (WFDs) is a new type of structure that integrates advantages of post‐tensioned precast concrete MRFs and self‐centering steel MRFs. In this paper, the configuration of the connection and design guidelines are presented. To further reduce damage to the connection under cyclic loading and facilitate implementation in practice, several significant improvements are proposed and experimentally validated in this study, including the following: (i) the welded connection is replaced by the bolted connection; (ii) aluminum plates are used for friction instead of brass plates to reduce the material costs without decreasing the energy dissipation capacity; and (iii) post‐tensioned tendons at the corners of the beam are replaced by a bundle of tendons at the beam centroid in order to facilitate the field assembly. The resulting improvements of seismic performances are experimentally demonstrated by 10 cyclic tests of two full‐scale SCPC beam–column connections. Numerical simulation of the proposed connection is conducted using the Open System for Earthquake Engineering Simulation (OpenSees) to replicate the experimental results. Seismic behaviors are taken into account, such as the gap opening/closing at the beam–column interface, the self‐centering capacity, and the friction energy dissipation. Good agreement is observed between the numerical simulation and the test results. The proposed SCPC connection with bolted WFDs is demonstrated to have good performance when subjected to cyclic loading. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
In this study, effects of panel zone yielding on the seismic performance of welded-flange-plate (WFP) connections are investigated. In this work, four full-scale beam-to-column connections were used to run the experiments under cyclic loading. The obtained results can potentially lead to a better understanding of the influence of the panel zone inelastic shear deformation on the cyclic behavior of WFP connections for external joints in steel moment resisting frames (SMRFs). The main parameter in the testing program was the panel zone strength having a wide variation to gain the different levels of panel zone yielding. Results showed that all specimens had a high connection rotation capacity to satisfy the requirements of special moment frame connections. However, specimens with different panel zone strengths could provide the different amount of energy dissipation. Severe beam buckling was followed by tearing along the k-line region of the beam in the plastic hinge location, as well as tearing of the beam at the nose of the bottom flange plates which were both observed as a predominant failure mode in the specimens with a stronger panel zone. However, specimens with weak panel zone could develop a significant plastic rotation without causing any major problem to the beam-to-column connection groove welds. Based on mentioned observations and considering the effect of panel zone yielding because of different panel zone strengths on the hysteresis behavior of specimens, failure modes, plastic rotation capacity, and energy dissipation, some modifications were proposed for design requirements of the panel zone strength.  相似文献   

10.
This study details a new moment connection that overcomes difficulties in achieving field‐weld quality and eliminates steel beam buckling encountered in steel moment connections. This study presents cyclic test and finite element analysis results of full‐scale subassemblies using steel reduced flange plates (RFPs) to connect steel beam flanges and the column without any other direct connection. Since the RFP connection is designed as strong column‐strong beam‐weak RFPs, the RFP functions as a structural fuse that eliminates weld fractures and beam buckling. Test and analytical results show that (1) the connections transferred the entire beam flexural strength to the column and reached an interstorey drift of 4% with minor strength degradation, (2) failure of the connections was owing to buckling or fracturing of the RFP and not of the beam, and (3) the RFP connection subassembly, modelled using the nonlinear finite element computer program ABAQUS, exhibited hysteretic behaviour similar to that of the flange plate (FP) moment connection subassembly. The inelastic buckling force of the RFP was also evaluated by nonlinear regression analyses performed on a nonlinear model that relates buckling force to RFP geometries. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
Moment connections in an existing steel building located in Kaohsiung, Taiwan were rehabilitated to satisfy seismic requirements based on the 2005 AISC seismic provisions. Construction of the building was ceased in 1996 due to financial difficulties and was recommenced in 2007 with enhanced connection performance. Steel moment connections in the existing building were constructed by groove welding the beam flanges and bolting the beam web to the column. Four moment connections, two from the existing steel building, were cyclically tested. A non‐rehabilitated moment connection with bolted web‐welded flanges was tested as a benchmark. Three moment connections rehabilitated by welding full‐depth side plates between the column face and beam flange inner side were tested to validate the rehabilitation performance. Test results revealed that (1) the non‐rehabilitated existing moment connection made by in situ welding process prior to 1996 had similar deformation capacity as contemporary connection specimens made by laboratory welding process, (2) all rehabilitated moment connections exhibited excellent performance, exceeding a 4% drift without fractures of beam flange groove‐welded joints, and (3) presence of the full‐depth side plates effectively reduced beam flange tensile strain near the column face by almost half compared with the non‐rehabilitated moment connection. The connection specimens were also modeled using the non‐linear finite element computer program ABAQUS to further confirm the effectiveness of the side plate in transferring beam moments to the column and to investigate potential sources of connection failure. A design procedure was made based on experimental and analytical studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
主要针对梁腹板带有摩擦耗能螺栓的自复位钢框架节点结构进行抗震性能和可更换性能的试验研究,探讨该类节点在往复荷载作用下的滞回性能以及节点域的变形特征。在参数选型的基础上,对5组钢框架节点试件进行了低周反复荷载作用下的拟静力试验,其中:4组试件具有自复位能力,分析了各试件的承载力、刚度、耗能性能和滞回特性等性能。综合研究结果表明:所提出的拼接节点能够利用摩擦螺栓的滑移提高节点的耗能能力,有效减少梁和柱主体构件的损伤,同时预应力筋提供了结构的自复位能力。试验结果表明:在地震作用之后,通过更换腹板及摩擦螺栓可以使结构的承载能力和耗能性能与震前基本一致,从而实现结构功能的快速恢复。  相似文献   

13.
Ten full-scale steel beam-to-column moment connections used in moment-resisting frames (MRFs) were tested to study the failure process, failure mode, strength and plastic rotation capacity. The specimens include one traditional welded flange-bolted web connection, one traditional fully welded connection, four beam flange strengthened connections, three beam flange weakened connections, and one through-diaphragm connection. The test results show that the connections with flange cover plates or with partly cut beam flanges satisfy the beam plastic rotation demand for ductile MRFs. From the measured stress profiles along the beam flange and beam web depth, the mechanics of brittle fracture at the end of the beam is discussed. Design recommendations for steel beam-to-column moment connections are proposed.  相似文献   

14.
利用超弹性SMA螺栓梁柱节点的耗能能力和自复位特性,将其引入到耗能跨而构建"自复位耗能跨",基于既有的节点试验研究结果对结构体系的滞回性能进行了探讨。在此基础上,以具有旗形滞回特征的单自由度体系为工具,对配置自复位耗能跨低多层钢框架体系的能量系数进行推导。能量系数可以合理量化具有旗形滞回规则结构的峰值响应需求,能量系数越低,表明地震动下结构的峰值响应越低。为了阐明滞回参数对能量系数的影响,对具有不同滞回参数组合可代表低多层结构的等效SDOF体系进行了非线性动力分析,参数组合包括周期、屈服后刚度比、延性系数及能量比。同时对能量系数的离散性也进行了分析。结果表明:能量系数及能量系数的离散性受结构周期、屈服后刚度比及延性系数影响较大,受能量比的影响较小。  相似文献   

15.
通过低周反复加载试验对6个锚定式方钢管混凝土柱-H形钢梁节点进行了试验研究,研究了不同轴压比情况下节点的破坏模式、延性、耗能性能、强度及刚度退化等。试验结果表明,破坏之前节点具有良好的滞回性能、延性及耗能能力,满足现行抗震规范的要求。锚定式方钢管混凝土梁柱节点可以用于拉力较小的节点。文中提出了有关的设计建议。  相似文献   

16.
Brittle fractures were observed at the welded beam‐to‐column connections of a number of steel moment frame buildings following the M6.7 1994 Northridge earthquake. Such fractures cause a rapid loss of connection strength and stiffness, as well as a sudden release of the strain energy stored by the connection at the time of fracture. Immediately following the fracture, a number of highly transient phenomena occur locally in the members adjacent to the connection, as well as globally in the structure as a whole. Four significant local phenomena were observed locally during shaking table tests of a one‐third scale, two‐story, one‐bay steel moment frame in which quasi‐brittle beam‐to‐column fractures occurred: (a) change in beam deflected shape; (b) change in moment distribution in adjacent members; (c) generation and propagation of elastic waves; and (d) initiation of dynamic modal response at the member level. Owing to the highly transient nature of these phenomena, they were observed to have second‐order effects on overall behavior of the system. In comparison, the reductions in local strength and stiffness caused by the fractures had much more significant effects on system behavior. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
This paper presents the development, experimental testing, and numerical modelling of a new hybrid timber‐steel moment‐resisting connection that is designed to improve the seismic performance of mid‐rise heavy timber moment‐resisting frames (MRF). The connection detail incorporates specially designed replaceable steel links fastened to timber beams and columns using self‐tapping screws. Performance of the connection is verified through experimental testing of four 2/3 scale beam‐column connections. All 4 connection specimens met the acceptance criteria specified in the AISC 341‐10 provisions for steel moment frames and exhibit high strength, ductility, and energy dissipation capacity up to storey drifts exceeding 4%. All of the timber members and self‐tapping screw connections achieved their design objective, remaining entirely elastic throughout all tests and avoiding brittle modes of failure. To assess the global seismic performance of the newly developed connection in a mid‐rise building, a hybrid timber‐steel building using the proposed moment‐resisting connection is designed and modelled in OpenSees. To compare the seismic performance of the hybrid MRF with a conventional steel MRF, a prototype steel‐only building is also designed and modelled in OpenSees. The building models are subject to a suite of ground motions at design basis earthquake and maximum credible earthquake hazard levels using non‐linear time history analysis. Analytical results show that drifts and accelerations of the hybrid building are similar to a conventional steel building while the foundation forces are significantly reduced for the hybrid structure because of its lower seismic weight. The results of the experimental program and numerical analysis demonstrate the seismic performance of the proposed connection and the ability of the hybrid building to achieve comparable seismic performance to a conventional steel MRF.  相似文献   

18.
Reinforced concrete wide beam–column connections have been used in low‐to‐moderate seismicity regions despite little information being available on their seismic performance. This research was conducted to clarify experimentally the hysteretic behaviour and ultimate energy dissipation capacity (UEDC) of this type of existing connection under lateral dynamic earthquake loadings. For this purpose, ? scale models were constructed and tested on a shaking table until they collapsed. The exterior connection behaved as a strong column–weak beam mechanism, and the interior connection as a weak column–strong beam mechanism. The averaged UEDC of the connections in each domain of loading, normalized with respect to the product of the yield strength and yield displacement, were about 6 and 5 for the exterior and interior connections, respectively. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
The work presented is aimed at the investigation of the influence of beam‐to‐column connections on the seismic response of MR‐Frames, with and without ‘set‐backs’, designed according to the Theory of Plastic Mechanism Control. The investigated connection typologies are four partial strength connections whose structural details have been designed to obtain the same flexural resistance. The first three joints are designed by means of hierarchy criteria based on the component approach and are characterized by different location of the weakest joint component, leading to different values of joint rotational stiffness and plastic rotation supply and affecting the shape of the hysteresis loops governing the dissipative capacity. The last typology is a beam‐to‐column connection equipped with friction pads devoted to the dissipation of the earthquake input energy, thus preventing the connection damage. An appropriate modelling is needed to accurately represent both strength and deformation characteristics, especially with reference to partial‐strength connections where the dissipation of the earthquake input energy occurs. To this aim, beam‐to‐column joints are modelled by means of rotational inelastic springs located at the ends of the beams whose moment‐rotation curve is characterized by a cyclic behaviour which accounts for stiffness and strength degradation and pinching phenomena. The parameters characterizing the cyclic hysteretic behaviour have been calibrated on the base of experimental results aiming to the best fitting. Successively, the prediction of the structural response of MR‐Frames, both regular frames and frames with set‐backs, equipped with such connections has been carried out by means of both push‐over and Incremental Dynamic Analyses. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
为验证新型装配式圆钢管柱-钢梁节点的破坏模式及抗震性能,进行了3个十字形节点的低周反复循环加载试验。研究了不同试件节点的破坏模式、滞回性能、延性及耗能性能等。试验结果表明:试件的位移延性系数为3.38~3.44,能量耗散系数为1.72~2.25,节点具有良好的滞回性能、延性及耗能能力,满足现行规范设计要求。建议在采用新型装配式节点时,梁柱连接处可同时采用加强型连接或骨式连接,以获得良好的抗震性能。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号