首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
INAA, ICP‐AES and ICP‐MS were used to elementally characterise four environmental reference materials – NIST SRM 1646a (Estuarine Sediment), NIST SRM 1400 (Bone Ash), IAEA‐395 (Urban Dust) and IAEA‐450 (Algae). An analytical scheme consisting of the three methods was first applied to NIST SRM 1646a to validate the methodology because it has been extensively analysed and has certified values for many elements. With repeated analyses of NIST SRM 1646a, the accuracy and measurement repeatability of the data obtained were evaluated based on two statistical calculations (zeta‐score and Horwitz ratio) and were observed to be good enough for the analytical scheme to be applied to similar sorts of environmental/geochemical samples. Applying the same approach to NIST SRM 1400, IAEA‐395 and IAEA‐450, enabled mass fractions of 29, 38 and 28 elements to be determined, respectively. Among these results, the data for rare earth elements are of particular interest, not only for IAEA‐450 but also for the other three reference samples. The data for Pr, Gd, Dy, Ho, Er and Tm in NIST SRM 1646a are newly reported in this study. By using small test portions (< 100 mg) for NIST SRM 1646a and IAEA‐395, and recommended minimum amounts for NIST SRM 1400 and IAEA‐450, sample homogeneity was evaluated.  相似文献   

2.
Advances in the chemical, crystallographic and isotopic characterisation of geological and environmental materials can often be ascribed to technological improvements in analytical hardware or to innovative approaches to data acquisition and/or its interpretation. This biennial review addresses key laboratory methods that form much of the foundation for analytical geochemistry; again, this contribution is presented as a compendium of laboratory techniques. We highlight advances that have appeared since January 2012 and that are of particular significance for the chemical and isotopic characterisation of geomaterials. Prominent scientists from the selected analytical fields present publications they judge to be particular noteworthy, providing background information about the method and assessing where further opportunities might be anticipated. In addition to the well‐established technologies such as thermal ionisation mass spectrometry and plasma emission spectroscopy, this publication also presents new or rapidly growing methods such as electron backscattered diffraction analysis and atom probe tomography – a very sensitive method providing atomic scale information.  相似文献   

3.
This GGR biennial critical review covers developments and innovations in key analytical methods published since January 2014, relevant to the chemical, isotopic and crystallographic characterisation of geological and environmental materials. In nine selected analytical fields, publications considered to be of wide significance are summarised, background information is provided and their importance evaluated. In addition to instrumental technologies, this review also presents a summary of new developments in the preparation and characterisation of rock, microanalytical and isotopic reference materials, including a précis of recent changes and revisions to ISO guidelines for reference material characterisation and reporting. Selected reports are provided of isotope ratio determinations by both solution nebulisation MC‐ICP‐MS and laser ablation‐ICP‐MS, as well as of radioactive isotope geochronology by LA‐ICP‐MS. Most of the analytical techniques elaborated continue to provide new applications for geochemical analysis; however, it is noted that instrumental neutron activation analysis has become less popular in recent years, mostly due to the reduced availability of nuclear reactors to act as a neutron source. Many of the newer applications reported here provide analysis at increasingly finer resolution. Examples include atom probe tomography, a very sensitive method providing atomic scale information, nanoscale SIMS, for isotopic imaging of geological and biological samples, and micro‐XRF, which has a spatial resolution many orders of magnitude smaller than conventional XRF.  相似文献   

4.
Trace amounts of three halogens (chlorine, bromine and iodine) in seventeen U.S. Geological Survey (USGS) geochemical reference materials were determined by radiochemical neutron activation analysis (RNAA). The materials analysed were AGV‐2 (andesite), BCR‐2, BHVO‐2 and BIR‐1a (basalts), CLB‐1 (coal), COQ‐1 (carbonatite), DGPM‐1 (disseminated gold ore), DNC‐1a (dolerite), DTS‐2b (dunite), GSP‐2 (granodiorite), Nod‐A‐1 and Nod‐P‐1 (manganese nodules), QLO‐1a (quartz latite), SBC‐1 (marine shale), SDC‐1 (mica schist), SGR‐1b (shale rock) and W‐2a (diabase). The chlorine, bromine and iodine contents were determined to be 5.64 mg kg?1 (BIR‐1a) to 4410 mg kg?1 (Nod‐A‐1), 0.039 mg kg?1 (BIR‐1a) to 52.1 mg kg?1 (CLB‐1), and 0.041 mg kg?1 (BIR‐1a) to 599 mg kg?1 (CLB‐1), respectively. The RNAA data of the three halogens were compared with the corresponding data in the literature.  相似文献   

5.
Inter‐laboratory comparison of laser ablation ICP‐MS and SIMS U‐Pb dating of synthetic detrital zircon samples provides an insight into the state‐of‐the art of sedimentary provenance studies. Here, we report results obtained from ten laboratories that routinely perform this type of work. The achieved level of bias was mostly within ± 2% relative to the ID‐TIMS U‐Pb ages of zircons in the detrital sample, and the variation is likely to be attributed to variable Pb/U elemental fractionation due to zircon matrix differences between the samples and the reference materials used for standardisation. It has been determined that ~ 5% age difference between adjacent age peaks is currently at the limit of what can be routinely resolved by the in situ dating of detrital zircon samples. Precision of individual zircon age determination mostly reflects the data reduction and procedures of measurement uncertainty propagation, and it is largely independent of the instrumentation, analytical technique and reference samples used for standardisation. All laboratories showed a bias towards selection of larger zircon grains for analysis. The experiment confirms the previously published estimates of the minimum number of grains that have to be analysed in order to detect minor zircon age populations in detrital samples.  相似文献   

6.
This study reports a robust procedure that permits precise measurement of all fourteen naturally occurring rare earth element (REE) concentrations, present at ng kg?1 to sub ng kg?1 levels, in ~ 100 ml seawater. This procedure is simple and can be routinely applied to measure seawater REEs with relatively high sample throughput. The procedure involves addition of a 142Ce‐145Nd‐171Yb‐enriched spike mixture, iron co‐precipitation, REE purification with chromatographic separation and the use of a magnetic‐sector‐field ICP‐MS (Element 2) coupled with a desolvating sample introduction system (Aridus 1). Critical steps of the procedure, including co‐precipitation pH and matrix removal, have been optimised through a set of experiments described here. The accuracy of the new procedure was assessed against a gravimetric mixture of REEs, and the precision was demonstrated by repeated measurement of two well‐mixed natural seawaters. Repeated analyses of these seawater reference materials (RMs), using ~ 100 ml seawater for each aliquot, indicate precision of 3% (1s) for the REEs. Measured REE concentrations of two uncertified seawater RMs (CASS‐4 and NASS‐5) are consistent with published values, and REE concentrations of the GEOTRACES intercalibration samples show good agreement with those reported by other participant laboratories. REE concentrations for other intercalibration samples (SAFe and Arctic PS70) are also reported.  相似文献   

7.
X-ray computed tomography (XCT) is a powerful 3D imaging technique that has been used to investigate meteorites, mission-returned samples, and other planetary materials of all scales from dust particles to large rocks. With this technique, a 3D volume representing the X-ray attenuation (which is sensitive to composition and density) of the materials within an object is produced, allowing various components and textures to be observed and quantified. As with any analytical technique, a thorough understanding of the underlying physical principles, system components, and data acquisition parameters provides a strong foundation for the optimal acquisition and interpretation of the data. Here we present a technical overview of the physics of XCT, describe the major components of a typical laboratory-based XCT instrument, and provide a guide for how to optimize data collection for planetary materials using such systems. We also discuss data processing, visualization and analysis, including a discussion of common data artifacts and how to minimize them. We review a variety of recent studies in which XCT has been used to study extraterrestrial materials and/or to address fundamental problems in planetary science. We conclude with a short discussion of anticipated future directions of XCT technology and application.  相似文献   

8.
Compared with solution ICP‐MS, LA‐ICP‐MS studies have thus far reported comparatively few external reference data for accuracy estimates of experiments. This is largely the result of a paucity of available reference materials of natural composition. Here, we report an evaluation of natural glass (obsidian) as an inexpensive and widely available external reference material. The homogeneity of over forty elements in six different obsidian samples was assessed by LA‐ICP‐MS. Accuracy was tested with two obsidian samples that were fully characterised by electron probe microanalysis and solution ICP‐MS. Laser ablation experiments were performed with a variety of ablation parameters (fluence, spot sizes, ablation repetition rates) and calibration approaches (natural vs. synthetic reference materials, and different internal standard elements) to determine the best practice for obsidian analysis. Furthermore, the samples were analysed using two different laser wavelengths (193 nm and 213 nm) to compare the effect of potential ablation‐related phenomena (e.g., fractionation). Our data indicate that ablation with fluences larger than 6 J cm?2 and repetition rates of 5 or 10 Hz resulted in the most accurate results. Furthermore, synthetic NIST SRM 611 and 612 glasses worked better as reference materials compared with lower SiO2 content reference materials (e.g., BHVO‐2G or GOR128‐G). The very similar SiO2 content of the NIST SRM glasses and obsidian (i.e., matrix and compositional match) seems to be the first‐order control on the ablation behaviour and, hence, the accuracy of the data. The use of different internal standard elements for the quantification of the obsidian data showed that Si and Na yielded accurate results for most elements. Nevertheless, for the analysis of samples with high SiO2 concentrations, it is recommended to use Si as the internal standard because it can be more precisely determined by electron probe microanalysis. At the scale of typical LA analyses, the six obsidian samples proved to be surprisingly homogenous. Analyses with a spot size of 80 μm resulted in relative standard deviations (% RSD) better than 8% for all but the most depleted elements (e.g., Sc, V, Ni, Cr, Cu, Cd) in these evolved glasses. The combined characteristics render obsidian a suitable, inexpensive and widely available, external quality‐control material in LA‐ICP‐MS analysis for many applications. Moreover, obsidian glass is suited for tuning purposes, and well‐characterised obsidian could even be used as a matrix‐matched reference material for a considerable number of elements in studies of samples with high SiO2 contents.  相似文献   

9.
A total of twenty-five bibliographic reviews were published between 1979 and 2004 in Geostandards Newsletter, subsequently renamed Geostandards and Geoanalytical Research, which list more than 5500 papers. These cited references contain information about geochemical reference materials, analytical methods or address general issues concerning the use of reference materials (protocols for sampling, certification, or new analytical techniques). In support of emerging fields of interest in geoanalysis, frequently associated with environmental research, and reflecting the increased breadth in the topics addressed by the Journal, new reference headings were added over time, while retaining the original style and format of the review. Reference management software was used to extract information from these publications related to methods, reference materials and analytes. Major developments during these 25 years, reflecting both advances in laboratory hardware as well as shifts in research interests, can readily be seen in both the types of reference materials being studied and in nature of the new analytical protocols that were developed. These two topics were the core foci of the twenty-five reviews, though much more information might also be extracted from this extensive resource.  相似文献   

10.
11.
This study uses MC‐ICP‐MS for the precise analysis of the stable tin isotopic composition in ore minerals of tin (cassiterite, stannite), tin metal and tin bronze. The ultimate goal is to determine the provenance of tin in ancient metal objects. We document the isotope compositions of reference materials and compare the precision of different isotope ratios and the accuracy of different procedures of mass fractionation correction. These data represent a base with which isotopic data of future studies can be directly compared. The isotopic composition of cassiterite and stannite can be determined after reduction to tin metal and bronze, respectively. Both metals readily dissolve in HCl, but while the solutions of tin metal can be directly measured, the bronze solutions must be purified with an anion exchanger. The correction of the mass bias is best performed with an internal Sb standard and an empirical regression method. A series of Sn isotope determinations on commercially available mono‐element Sn solutions as well as reference bronze materials and tin minerals show fractionations ranging from about ?0.09‰ to 0.05‰/amu. The combined analytical uncertainty (2s) was determined by replicate dissolutions of reference materials of bronze (BAM 211, IARM‐91D) and averages at about 0.005‰/amu.  相似文献   

12.
The interest in variations of barium (Ba) stable isotope amount ratios in low and high temperature environments has increased over the past several years. Characterisation of Ba isotope ratios of widely available reference materials is now required to validate analytical procedures and to allow comparison of data obtained by different laboratories. We present new Ba isotope amount ratio data for twelve geological reference materials with silicate (AGV‐1, G‐2, BHVO‐1, QLO‐1, BIR‐1, JG‐1a, JB‐1a, JR‐1 and JA‐1), carbonate (IAEA‐CO‐9) and sulfate matrices (IAEA‐SO‐5 and IAEA‐SO‐6) relative to NIST SRM 3104a. In addition, two artificially fractionated in‐house reference materials BaBe12 and BaBe27 (δ137/134Ba = ?1.161 ± 0.049‰ and ?0.616 ± 0.050‰, respectively) are used as quality control solutions for the negative δ‐range. Accuracy of our data was assessed by interlaboratory comparison between the University of Bern and the United States Geological Survey (USGS). Data were measured by MC‐ICP‐MS (Bern) and TIMS (USGS) using two different double spikes for mass bias correction (130Ba–135Ba and 132Ba–136Ba, respectively). MC‐ICP‐MS measurements were further tested for isobaric and non‐spectral matrix effects by a number of common matrix elements. The results are in excellent agreement and suggest data accuracy.  相似文献   

13.
Coltan (the African trade name for columbite‐tantalite, a tantalum ore) is one of several raw materials that finance the civil wars in the eastern provinces of the Democratic Republic of the Congo. To improve the transparency along the tantalum trade chain, a ‘certificate of origin’ for so‐called ‘conflict minerals’ has been recommended by the United Nations. Accordingly, the German Federal Institute for Geosciences and Natural Resources (BGR) has developed an analytical fingerprint procedure for coltan. Mineral formation age, modal mineralogy and chemical composition are important fingerprint parameters. The original workflow to obtain these parameters was streamlined and is now based on mineral liberation analysis and LA‐ICP‐MS. The use of an ICP‐MS instrument with a detector system covering an extended linear dynamic range and the application of an internal standard‐independent calibration strategy allowed data for major and trace element determination and mineral formation age estimates to be obtained simultaneously. The analytical results of this new approach were compared with analytical techniques of the original workflow and showed excellent agreement in terms of mineralogical and chemical characterisation and mineral formation age of coltan samples. Within a test, samples of different origin were allocated correctly and simple, binary mixtures were also identified successfully.  相似文献   

14.
A measurement procedure for the rapid acquisition of U‐Pb dates for detrital zircons by quadrupole LA‐ICP‐MS was developed. The procedure achieves a threefold increase in measurement efficiency compared with the most commonly used methods. Utilising reduced background counting times and a shortened ablation period, a throughput of ~ 130 measurements/h can be achieved. The measurement procedure was characterised and validated using data from thirty‐nine sessions acquired over a twelve‐month period. Systematic measurement error in 206Pb/238U dates for reference materials used for quality control with ages between 28.2 and 2672 Ma was < 1.5%. Average measurement uncertainty, including both random and systematic components, was 1–4% (2s). Interrogation of time‐resolved calculated dates and signal intensities for each measurement allows for the detection and elimination of portions of measurements exhibiting age heterogeneities, zoning, lead loss and contamination by common lead. The measurement procedure diminishes the need to acquire cathodoluminescence imagery for routine detrital zircon applications further increasing throughput and reducing cost. The utility of the measurement procedure is demonstrated by the measurement of samples previously characterised by LA‐MC‐ICP‐MS.  相似文献   

15.
The low detection limits and multi‐element capability of inductively coupled plasma‐mass spectrometry (ICP‐MS) makes it an attractive option in a wide range of environmental, medical, biological, industrial and archaeological applications. Quadrupole ICP‐MS is used to determine element concentrations in a diverse range of sample types, often very different from the geological applications for which ICP‐MS was originally developed. Whilst modern instruments are robust and capable of a high degree of automation, it is essential that users of both instrumentation and data are aware of the strengths and limitations of the technique. Many people who are now involved with the operation and application of ICP‐MS instruments are not specialists in the field, as was usually the case amongst early operators. This back‐to‐basics review is aimed at the novice user and includes a guide to ICP‐MS instrumentation and performance. Whilst solids, liquids and gases can all be measured by ICP‐MS, discussion of sample introduction is limited to liquids. Requirements for producing good quality data, including aspects of sample preparation, calibration, and methods of interference limitation are also discussed.  相似文献   

16.
This paper contains the results of an extensive isotopic study of United States Geological Survey GSD‐1G and MPI‐DING reference glasses. Thirteen different laboratories were involved using high‐precision bulk (TIMS, MC‐ICP‐MS) and microanalytical (LA‐MC‐ICP‐MS, LA‐ICP‐MS) techniques. Detailed studies were performed to demonstrate the large‐scale and small‐scale homogeneity of the reference glasses. Together with previously published isotopic data from ten other laboratories, preliminary reference and information values as well as their uncertainties at the 95% confidence level were determined for H, O, Li, B, Si, Ca, Sr, Nd, Hf, Pb, Th and U isotopes using the recommendations of the International Association of Geoanalysts for certification of reference materials. Our results indicate that GSD‐1G and the MPI‐DING glasses are suitable reference materials for microanalytical and bulk analytical purposes.  相似文献   

17.
Three synthetic reference glasses were prepared by directly fusing and stirring 3.8 kg of high‐purity oxide powders to provide reference materials for microanalytical work. These glasses have andesitic major compositions and are doped with fifty‐four trace elements in nearly identical abundance (500, 50, 5 µg g?1) using oxide powders or element solutions, and are named ARM‐1, 2 and 3, respectively. We further document that sector‐field (SF) ICP‐MS (Element 2 or Element XR) is capable of sweeping seventy‐seven isotopes (from 7Li to 238U, a total of sixty‐eight elements) in 1 s and, thus, is able to quantify up to sixty‐eight elements by laser sampling. Micro‐ and bulk analyses indicate that the glasses are homogeneous with respect to major and trace elements. This paper provides preliminary data for the ARM glasses using a variety of analytical techniques (EPMA, XRF, ICP‐OES, ICP‐MS, LA‐Q‐ICP‐MS and LA‐SF‐ICP‐MS) performed in ten laboratories. Discrepancies in the data of V, Cr, Ni and Tl exist, mainly caused by analytical limitations. Preliminary reference and information values for fifty‐six elements were calculated with uncertainties [2 relative standard error (RSE)] estimated in the range of 1–20%.  相似文献   

18.
This review documents developments and applications in the field of isotope ratio determination, as reflected in the literature for the Earth and Environmental Sciences for the years 2006 and 2007. The emphasis is predominantly on applications, reflecting the enormous diversity of problems to which isotopic analysis can now be applied, but viewed in the context of rapid uptake of new analytical technologies and significant new drivers of research output.  相似文献   

19.
LA‐ICP‐MS is one of the most promising techniques for in situ analysis of geological and environmental samples. However, there are some limitations with respect to measurement accuracy, in particular for volatile and siderophile/chalcophile elements, when using non‐matrix‐matched calibration. We therefore investigated matrix‐related effects with a new 200 nm femtosecond (fs) laser ablation system (NWRFemto200) using reference materials with different matrices and spot sizes from 10 to 55 μm. We also performed similar experiments with two nanosecond (ns) lasers, a 193 nm excimer (ESI NWR 193) and a 213 nm Nd:YAG (NWR UP‐213) laser. The ion intensity of the 200 nm fs laser ablation was much lower than that of the 213 nm Nd:YAG laser, because the ablation rate was a factor of about 30 lower. Our experiments did not show significant matrix dependency with the 200 nm fs laser. Therefore, a non‐matrix‐matched calibration for the multi‐element analysis of quite different matrices could be performed. This is demonstrated with analytical results from twenty‐two international synthetic silicate glass, geological glass, mineral, phosphate and carbonate reference materials. Calibration was performed with the certified NIST SRM 610 glass, exclusively. Within overall analytical uncertainties, the 200 nm fs LA‐ICP‐MS data agreed with available reference values.  相似文献   

20.
Laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) was examined as a tool for measuring isotopic variation as a function of ablation depth in unpolished zircon from an Archaean metasediment specimen. This technique was able to identify micrometre‐thin (> 3 μm) isotopically distinct mineral domains characterised by ca. 100 Myr younger 207Pb/206Pb ages associated with 2s age uncertainties as low ~ 0.2%, as well as elevated U content relative to grain interiors (up to an order of magnitude). Our calculated drilling rate suggests that each laser pulse excavated depths of ~ 0.06 μm. Ages resolved through the LA‐ICP‐MS methods overlap the 2s uncertainties of 207Pb/206Pb ages measured using SIMS depth profiling on the same zircon population. The rims were further evinced by the detection of relative enrichment (> 3 orders of magnitude) in REE in the outermost micrometres of the same zircon, measured using a different and independent LA‐ICP‐MS depth profiling technique. We propose a LA‐ICP‐MS U–Pb technique capable of quickly identifying and quantifying rims, which are indication of late, yet geologically significant, fluid events that are otherwise undefined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号