首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Prediction of the seismic rotational displacements of retaining wall under passive condition is an important aspect of design in earthquake prone region. In this paper, the pseudo-dynamic method is used to compute the rotational displacements of rigid retaining wall supporting cohesionless backfill under seismic loading for the passive earth pressure condition. The proposed method considers time, phase difference and effect of amplification in shear and primary waves propagating through both the backfill and the retaining wall. The influence of ground motion characteristics on rotational displacement of the wall is evaluated. Also the effects of variation of parameters like wall friction angle, soil friction angle, amplification factor, shear wave velocity, primary wave velocity, period of lateral shaking, horizontal and vertical seismic accelerations on the rotational displacements are studied. The rotational displacement of the wall increases substantially with increase in amplification of both shear and primary waves, time of input motion, period of lateral shaking and decreases with increase in soil friction angle, wall friction angle. The rotational displacements of the wall also increase when the effect of wall inertia is taken into account. Results are provided in graphical form.  相似文献   

2.
A new seismic energy dissipation shear wall structure is proposed in this paper. The new shear wall is one with purposely built‐in vertical slits within the wall panel, and rubber belts as seismic energy dissipation devices are installed in the vertical slits. In order to verify this concept, shaking table tests of a 10‐storey shear wall model with rubber belts filled in the vertical slits were carried out, and comparison of seismic behaviour was made between the new shear wall system and a shear wall with reinforced concrete connecting beams as energy dissipation. Furthermore, the seismic behaviour of this new shear wall is analysed by a finite element time history analysis method. The test and analysis show that the new shear wall system has a very good ability to dissipate seismic energy and is easy to use in engineering practice. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

3.
郭龙龙    袁康    裴城    王玉山   《世界地震工程》2019,35(4):060-67
针对我国村镇地区仍广泛存在生土结构房屋,且其结构整体性及抗震性能较差的现状,提出一种可有效提高其抗震性能、具有施工便捷性和装配属性的新型钢节点木构架-生土墙结构形式。进行了新型钢节点木构架-生土墙与农房中常见的素生土墙、上土坯下砖砌体混砌墙、传统榫接木构架-生土墙的拟静力对比试验,比较了4个墙体试件的破坏形态、滞回曲线和骨架曲线特征,以及延性系数、耗能能力、极限层间位移角等抗震性能指标。研究表明:素生土墙和上土坯下砖砌体混砌墙抗震性能较差,木构架的约束作用可有效提升生土墙的抗剪承载力和延性,新型钢节点连接的木构架-生土墙抗震性能优于榫接形式,具备一定的推广应用价值。  相似文献   

4.
本文提出了抗震耗能剪力墙结构的新型式,新型剪力墙的墙板中人为地设置了竖缝,并在竖缝中设置各种型式的耗能装置来控制结构的动力性能,如:结构的侧向刚度、延性、自振频率等,为了验证这一设想,本文进行了两个10带层竖缝剪力墙模型的振动台试验,通过试验数据分析和结构非线性动力反应计算分析对两个模型的抗震性能进行了研究。  相似文献   

5.
A new structural system for earthquake resistant steel structures is investigated in this paper. This new framing system, called the knee-brace-frame (KBF), is a braced frame with diagonal braces connected to ductile knee members. The diagonal braces provide the lateral stiffness, whereas the knee anchors yield in flexure to dissipate energy during severe seismic excitation. To assess the inelastic characteristics of the KBF, a large scale model of a KBF was tested using the pseudodynamic test procedure. The experimental results are compared with analytical results obtained from a DRAIN-2D model. It is found that, with an appropriate design of knee anchors, the KBF can be made to be ductile to dissipate energy during severe seismic excitation.  相似文献   

6.
A roller seismic isolation bearing is proposed for use in highway bridges. The bearing utilizes a rolling mechanism to achieve seismic isolation and has a zero post‐elastic stiffness under horizontal ground motions, a self‐centering capability, and unique friction devices for supplemental energy dissipation. The objectives of this research are to investigate the seismic behavior of the proposed bearing using parametric studies (1) with nonlinear response history analysis and (2) with equivalent linear analysis according to the AASHTO guide specifications, and by comparing the results from both analysis methods (3) to evaluate the accuracy of the AASHTO equivalent linear method for predicting the peak displacement of the proposed bearing during an earthquake. Twenty‐eight ground motions are used in the studies. The parameters examined are the sloping angle of the intermediate plate of the bearing, the amount of friction force for supplemental energy dissipation, and the peak ground acceleration levels of the ground motions. The peak displacement and base shear of the bearing are calculated. Results of the studies show that a larger sloping angle does not reduce the peak displacement for most of the parametric combinations without friction devices. However, for parametric combinations with friction devices, it allows for the use of a higher friction force, which effectively reduces the peak displacement, while keeping a self‐centering capability. The AASHTO equivalent linear method may underestimate the peak displacement by as much as 40%. Vertical ground motions have little effect on the peak displacement, but significantly increase the peak base shear. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
This paper presents the results of 12 full‐scale tests on buckling‐restrained brace (BRB) specimens. A simple‐to‐fabricate all‐steel encasing joined by high‐strength bolts was used as the buckling‐restrainer mechanism. Steel BRBs offer significant energy dissipation capability through nondeteriorating inelastic response of an internal ductile core. However, seismic performance of BRBs is characterized by interaction between several factors. In this experimental study, the effects of core‐restrainer interfacial condition, gap size, loading history, bolt spacing, and restraining capacity are evaluated. A simple hinge detail is introduced at the brace ends to reduce the flexural demand on the framing components. Tested specimens with bare steel contact surfaces exhibited satisfactory performance under the American Institute of Steel Construction qualification test protocol. The BRBs with friction‐control self‐adhesive polymer liners and a graphite‐based dry lubricant displayed larger cumulative inelastic ductility under large‐amplitude cyclic loading, exceeding current code minimum requirements. The BRB system is also examined under repeated fast‐rate seismic deformation history. This system showed significant ductility capacity and remarkable endurance under dynamic loading. Furthermore, performance is qualified under long‐duration loading history from subduction zone's megathrust type of earthquake. Predictable and stable performance of the proposed hinge detail was confirmed by the test results. Internally imposed normal thrust on the restrainer is measured using series of instrumented bolts. Weak‐ and strong‐axis buckling responses of the core are examined. Higher post‐yield stiffness was achieved when the latter governed, which could be advantageous to the overall seismic response of braced frames incorporating BRBs.  相似文献   

8.
带耗能腋撑竖向不规则短肢剪力墙结构减震性能分析   总被引:2,自引:0,他引:2  
在不影响建筑使用空间前提下,提出在抗侧构件不连续处设置耗能腋撑以改善竖向不规则结构抗震性能。以底部大空间短肢剪力墙结构为研究对象,利用大型通用有限元程序ETABS研究耗能器类型与场地土对耗能腋撑工作性能和竖向不规则结构受力性能的影响。研究表明,黏滞型耗能腋撑对文中分析模型各楼层地震反应有较好的控制效果,对转换层处层间位移角与层剪力最大值减幅最大,分别为40.14%和15.66%,对顶层加速度与基底剪力峰值的最大减幅分别为16.06%和23.57%,黏滞型耗能腋撑最大能耗散输入结构能量的42%,而黏弹型耗能腋撑对结构的控制效果不理想;当地震震级较大、震中距较小时,耗能腋撑对坚硬与软弱场地土的模型结构控制作用相差不大,减震位移比在转换层处达到最小值0.76;随着震级减小或震中距增大,耗能腋撑对该模型结构的控制作用随场地土变硬而逐渐增强,其减震位移比介于0.68~0.74之间。  相似文献   

9.
挡土墙地震被动土压力的拟动力分析   总被引:5,自引:0,他引:5  
杨剑 《地震学刊》2012,(3):365-371
对地震土压力的研究是地震区挡土墙安全设计的一项重要课题。地震条件下,目前的研究主要是给出了土压力的近似拟静力解析解。本文采用可考虑动力荷载下的周期和纵波及横波效应的拟动力方法,对挡土墙后的地震被动土压力进行分析。在挡土墙后平面滑裂面假设的基础上,考虑了水平和垂直向地震加速度、纵波速度、横波速度、挡土墙摩擦角、填土内摩擦角、填土坡角对地震被动土压力的影响。与Mononobe-Okabe理论的拟静力法不同的是,用本方法得出了沿墙身地震被动土压力是非线性变化的结果,这更符合地震条件下土压力的变化规律。  相似文献   

10.
A simple analytical procedure is developed for calculating the seismic energy dissipated by a linear SDOF system under an earthquake ground excitation. The ground excitation is specified by its pseudo-velocity spectra and effective duration whereas the SDOF system is defined by its natural period of vibration and viscous damping ratio. However, the derived relationship for the energy dissipation demand under an earthquake excitation is sensitive neither to the viscous damping ratio nor the ductility ratio when the SDOF system undergoes inelastic response. Accordingly, the proposed relationship can be employed in an energy-based seismic design procedure for determining the required energy dissipation capacity of a structural system.  相似文献   

11.
Seismic performance of structures is related to the damage inflicted on the structure by the earthquake, which means that formulation of performance‐based design is inherently coupled with damage assessment of the structure. Although the potential for cumulative damage during a long‐duration earthquake is generally recognized, most design codes do not explicitly take into account the damage potential of such events. In this paper, the classical low‐cycle fatigue model commonly used for seismic damage assessment is cast in a framework suitable for incorporating cumulative damage into seismic design. The model, in conjunction with a seismic input energy spectrum, may be used to establish an energy‐based seismic design. In order to ensure satisfactory performance in a structure, the cyclic plastic strain energy capacity of the structure is designed to be larger than or equal to the portion of seismic input energy contributing to cumulative damage. The resulting design spectrum, which depends on the duration of the ground motion, indicates that the lateral strength of the structure must be increased in order to compensate for the increased damage due to an increased number of inelastic cycles that occur in a long‐duration ground motion. Examples of duration‐dependent inelastic design spectra are developed using parameters currently available for the low‐cycle fatigue model. The resulting spectra are also compared with spectra developed using a different cumulative damage model. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
The energy balance and energy input of Single-Degree-of-Freedom (SDF) systems under earthquake motion is studied for elastic and inelastic systems. The maximum displacement of an inelastic system is related to that of an elastic system having the same initial stiffness and mass by considering the earthquake energy input per cycle of oscillation. With an assumption that the cyclic energy input is equal for both elastic and inelastic system for intermediate- and long-period systems, a simplified relation is suggested. Newmark's equal energy rule is shown to be the upper bound of the simplified relation; the lower bound of maximum response displacement is also derived in this paper. The numerical analysis results were mostly shown to fall between the proposed upper and lower bounds. A separate approximate relation is proposed for short-period systems. The reason for divergence from the suggested relations is discussed for short-period systems. Copyright © 1999 John Wiley & Sons Ltd.  相似文献   

13.
Allowing a structure to uplift and rock during an earthquake is one way in which activated forces can be capped and damage to the structure avoided or minimised. Slip‐friction connectors (also known as slotted‐bolt connectors) were originally developed for use in steel construction, but for this research have been adapted for use as hold‐downs in an experimental 2.4 m × 2.4 m rigid timber shear wall. A novel approach is used to achieve the desired sliding threshold in the connectors, and the wall uplifts when this threshold is reached. From a series of quasi‐static cyclic tests, it is shown that slip‐friction connectors can impart ductile and elasto‐plastic characteristics to what would otherwise be essentially brittle structures. Because forces on the wall were capped by the slip‐friction connectors to levels well below the design level, no damage to the wall was observed. Self‐centring potential was also found to be excellent. The slip‐friction connectors themselves are of a unique design and have proven to be robust and durable, adequately performing their duty even after almost 14 m of cumulative travel under high contact pressures. To resist base shear without unduly affecting rocking behaviour, a new type of shear‐key is proposed and implemented, and a procedure developed to quantify its influence on overall wall behaviour. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
本文通过弹性和弹塑性时程分析,研究了水平地震作用下梁铰型屈服RC框架模型结构的楼层屈服剪力系数、基本自振周期、楼层数3个因素对弹塑性位移增大系数的影响,通过非线性回归分析给出了弹塑性层间位移增大系数经验公式;通过分析滞回耗能沿楼层高度的分布,初步确定了梁铰型屈服RC框架结构的薄弱楼层位置;基于结构损伤分析,讨论了抗震规范中RC框架结构弹塑性层间位移角限值的水准。  相似文献   

16.
Bridge seismic isolation strategy is based on the reduction of shear forces transmitted from the superstructure to the piers by two means: shifting natural period and earthquake input energy reduction by dissipation concentrated in protection devices. In this paper, a stochastic analysis of a simple isolated bridge model for different bridge and device parameters is conducted to assess the efficiency of this seismic protection strategy. To achieve this aim, a simple nonlinear softening constitutive law is adopted to model a wide range of isolation devices, characterized by only three essential mechanical parameters. As a consequence of the random nature of seismic motion, a probabilistic analysis is carried out and the time modulated Kanai-Tajimi stochastic process is adopted to represent the seismic action. The response covariance in the state space is obtained by solving the Lyapunov equation for a stochastic linearized system. After a sensitivity analysis, the failure probability referred to extreme displacement and the mean value of dissipated energy are assessed by using the introduced stochastic indices of seismic bridge protection efficiency. A parametric analysis for protective devices with different mechanical parameters is developed for a proper selection of parameters of isolation devices under different situations.  相似文献   

17.
The seismic performance of a steel framed structure equipped with (i) friction damping devices and (ii) base isolators is compared. A parametric study based on energy concepts is performed first using time-history dynamic analysis to determine the optimum properties of the two systems when excited by an earthquake whose energy is distributed over a relatively broad frequency band (1940 El Centro, N-S). Using these same properties, the responses of the two structural systems are then examined when excited by earthquakes whose power content essentially is concentrated at the low frequency end of the energy spectrum (1977 Romania, Bucharest, N-S and 1985 Mexico, SCT E-W). The results of the study show that, while both systems similarly reduce the response of conventional structures to the California earthquake, the friction damped structure exhibits a superior performance under the low frequency earthquakes. Very large shear forces and displacements are observed when the Romania and Mexico earthquakes are applied to the base isolated structure, indicating that the performance of a base isolated structure depends on the characteristics of the site earthquake. By comparison, friction damped structures are shown to behave favourably under the three earthquakes studied; this suggests that friction damping devices offer a more consistent way of protecting structures during earthquakes.  相似文献   

18.
By advancing the technologies regarding seismic control of structures and development of earthquake resistance systems in the past decades application of different types of earthquake energy dissipation system has incredibly increased. Viscous damper device as a famous and the simplest earthquake energy dissipation system is implemented in many new structures and numerous number of researches have been done on the performance of viscous dampers in structures subjected to earthquake. The experience of recent severe earthquakes indicates that sometimes the earthquake energy dissipation devices are damaged during earthquakes and there is no function for structural control system. So, damage of earthquake energy dissipation systems such as viscous damper device must be considered during design of earthquake resistance structures.This paper demonstrates the development of three-dimensional elasto-plastic viscous damper element consisting of elastic damper in the middle part and two plastic hinges at both ends of the element which are compatible with the constitutive model to reinforce concrete structures and are capable to detect failure and damage in viscous damper device connections during earthquake excitation. The finite element model consists of reinforced concrete frame element and viscous damper element is developed and special finite element algorithm using Newmark׳s direct step-by-step integration is developed for inelastic dynamic analysis of structure with supplementary elasto-plastic viscous damper element. So based on all the developed components an especial finite computer program has been codified for “Nonlinear Analysis of Reinforced Concrete Buildings with Earthquake Energy Dissipation System”. The evaluation of seismic response of structure and damage detection in structural members and damper device was carried out by 3D modeling, of 3 story reinforced concrete frame building under earthquake multi-support excitation.  相似文献   

19.
Cyclic loading tests were performed on three one‐storey steel frames and four three‐storey concrete‐filled tube (CFT) moment frames reinforced with a new type of earthquake‐resisting element consisting of a steel plate shear wall with vertical slits. In this shear wall system, the steel plate segments between the slits behave as a series of flexural links, which provide fairly ductile response without the need for heavy stiffening of the wall. The steel shear walls and the moment frames behaved in a ductile manner up to more than 4% drift without abrupt strength degradation or loss of axial resistance. Results of these tests and complementary analysis provide a basis for an equivalent brace model to be employed in commercially available frame analysis programs. Test and analytical results suggest that the horizontal force is carried by the bolts in the middle portion of the wall–frame connection, while the vertical forces coupled with the moment in the connection are resisted by the bolts in the edge portion of the connection, for which the friction bolts in the connection should be designed. When sufficient transverse stiffening is provided, full plastic strength and non‐degrading hysteretic behaviour can be achieved for this new type of shear wall. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

20.
This paper describes a new seismic protection system for timber platform frame buildings, either for new construction or retrofit. The system consists in connecting the timber frame to a steel structure that includes hysteretic energy dissipators designed to absorb most of the seismic input energy thus protecting the timber frame and the other steel members; alternatively, the system might use other types of dissipative devices. The steel structure consists of four steel stacks (located at each of the four façades) and steel collectors embracing each slab; the stacks and the collectors are connected, at each floor level, through the energy dissipators. The steel structure is self‐supporting, that is, the timber frame is not affected by horizontal actions and can be designed without accounting for any seismic provision; in turn, the steel members do not participate in the main load‐carrying system. The timber‐steel interface is designed to avoid any stress concentration in the transfer of horizontal forces and to guarantee that the yielding of the dissipators occurs prior to any timber failure. The energy dissipation capacity of the suggested system is discussed, and an application example on a six‐story timber building is presented; this case corresponds to highly demanding conditions because of the relatively large building height and weight, the high local seismicity, and the soft soil condition. This research belongs to a wider project aiming to promote the structural use of timber by improving the seismic capacity of wooden buildings; this research includes experiments and advanced numerical simulation. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号