首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 721 毫秒
1.
Fault zone architecture plays an important role in flow regimes of hydrological systems. Fault zones can act as conduits, barriers, or conduits/barrier systems depending on their spatial architecture. The goal of this study is to determine the fault-zone permeability structure and its effect on the local hydrogeological system in the Dead Sea fault system. Permeability was measured on small-scale outcrop plug samples at four faults along the Dead Sea fault system, and large-scale slug tests in four boreholes, in different parts of the fault, at Yair fault in Israel. The research results show that values in the damage zone are two to five orders of magnitude higher than those of the fault core (~3.5?×?10?10, 1?×?10?15 m2 respectively), resulting in an anisotropic permeability structure for the overall fault zone and preferable flow parallel to the fault. A set of injection tests in the Yair fault damage zone revealed a water-pressure-dependent behavior. The permeability of this zone increases when employing a higher water pressure in the fault fracture-dominated damage zone, due to the reopening of fractures.  相似文献   

2.
A hydrostructural domain approach was tested and validated in fractured bedrock aquifers of the Gulf Islands, British Columbia (BC), Canada. Relative potential hydraulic properties for three hydrostructural domains in folded and faulted sedimentary rocks were derived using stochastically generated fracture data and hybrid discrete fracture network-equivalent porous media (DFN-EPM) modelling. Model-derived relative potential transmissivity values show good spatial agreement with transmissivity values obtained from pumping tests at selected sites. A spatial pattern of increasing transmissivity towards the southeast along the island chain is consistent between both datasets. Cluster analysis on relative potential permeability values obtained from a larger dataset for the region identified four clusters with geometric means of 9?×?10?13, 4?×?10?13, 2?×?10–13, and 3?×?10–14 m2. The general trend is an increase in relative potential permeability toward the southeast, emulating the trends identified in the site-specific analyses. Relative potential permeability values increase with proximity to the hinge line of a regional northwest-trending asymmetric fault propagation fold structure, and with proximity to superimposed high-angle north- and northeast-trending brittle faults. The results are consistent with documented patterns of structurally controlled fluid flow and show promise for use in regional characterization of fractured bedrock aquifers.  相似文献   

3.
Inflow data from 23 tunnels and galleries, 136 km in length and located in the Aar and Gotthard massifs of the Swiss Alps, have been analyzed with the objective (1) to understand the 3-dimensional spatial distribution of groundwater flow in crystalline basement rocks, (2) to assess the dependency of tunnel inflow rate on depth, tectonic overprint, and lithology, and (3) to derive the distribution of fracture transmissivity and effective hydraulic conductivity at the 100-m scale. Brittle tectonic overprint is shown to be the principal parameter regulating inflow rate and dominates over depth and lithology. The highest early time inflow rate is 1,300 l/s and has been reported from a shallow hydropower gallery intersecting a 200-m wide cataclastic fault zone. The derived lognormal transmissivity distribution is based on 1,361 tunnel intervals with a length of 100 m. Such interval transmissivities range between 10?9 and 10?1 m2/s within the first 200–400 m of depth and between 10?9 and 10?4 m2/s in the depth interval of 400–1,500 m below ground surface. Outside brittle fault zones, a trend of decreasing transmissivity/hydraulic conductivity with increasing depth is observed for some schistous and gneissic geological units, whereas no trend is identified for the granitic units.  相似文献   

4.
The hydraulic conductance of a large fault zone has been estimated by calibrating a regional groundwater flow model. Drops in groundwater elevations of over 80 m have been observed along a 15-km length of the Mission Creek fault, California, USA. The large drops in elevation are attributed to the reduced hydraulic conductivity of the fault materials. A conceptual and numerical model of the two hydrologic subbasins in Desert Hot Springs, separated by the Mission Creek fault, was developed. The model was used to estimate the hydraulic conductance along the fault. The parameter estimation involved calibrating the model with observed groundwater elevations from over 40 locations over a 60-year period. The fault hydraulic conductances were estimated assuming a linear trend in the fault length, yielding variations in the fault hydraulic conductance of about an order of magnitude along the fault length (2?×?10?11–4?×?10?10 1/s). When an average fault thickness of 35 m is assumed, the fault hydraulic conductivity values are estimated to be from three to five orders of magnitude lower than the surrounding materials. A sensitivity analysis indicated that assumptions made in the conceptual model do not significantly affect estimated fault hydraulic conductances.  相似文献   

5.
 In order to characterize the hydraulic properties of an aquifer in Finland comprising two subvertical fracture zones, observation-well responses were matched with generalized radial flow (GRF) type curves. The responses in six wells out of seven are consistent with the GRF model. The fractional flow dimensions (1–1.2 and 1.5) were determined by regression analysis of straight-line slopes and type-curve matching. In each test, the flow dimensions in the neighboring fracture zone range from 2–2.25. Comparisons of the late-time responses with the asymptotic GRF solution and the flow dimensions obtained by reversing the pumping and observation points suggest homogeneous hydraulic properties. Deviations in responses can be explained by flow-path tortuosity. After assessments of the extent of the flow and radial distances along the fracture system, hydraulic conductivities and storativities were determined from the results of the type-curve matching procedure. The obtained hydraulic conductivities are 1.3×10–5 to 7.9×10–5 m/s and 5.0×10–6 to 2.5×10–5 m/s for the western and the eastern fracture zones, respectively. The results were verified by applying them to analytical solutions for pumping wells. The calculated pumping-well responses are consistent with the observations. The analysis of flow dimension also enhances qualitative interpretations on the hydrogeology of fracture zones. Received, April 1997 · Revised, September 1997 · Accepted, May 1998  相似文献   

6.
Field studies of fracture systems associated with 58 normal fault zones crosscutting sedimentary rocks were performed in the Northwest German Basin. Fracture orientations, densities, apertures and lengths, as well as fault zone structural indices, were analysed separately for fault damage zones and host rocks. The results show a pronounced difference between carbonate and clastic rocks: mainly in carbonate rocks we found presence of clear damage zones, characterized by higher fracture densities than in the host rocks. While the maximum aperture is similar for both units, the percentage of fractures with large apertures is much higher in the damage zones than in the host rocks.Based on laboratory measurements of Young's moduli and field measurements of fracture densities, we calculate effective stiffnesses Ee, that is the Young's moduli of the in situ rock masses, within the normal fault zones. Compared with carbonate rocks, Ee computed for clastic-rock damage zones decreases significantly less due to lower fracture densities. We conclude that normal fault zones in carbonate rocks have more profound effects on enhancing permeability in fluid reservoirs than those in clastic rocks. The results are of great importance for modelling the hydromechanical behaviour of normal fault zones in subsurface fluid reservoirs.  相似文献   

7.
Kinmen Island is a small, tectonically stable, granitic island that has been suffering from a scarcity of fresh water resources due to excessive annual evapotranspiration over annual precipitation. Recent studies further indicate that shallow (0–70 m) sedimentary aquifers, the major sources of groundwater supply, have already been over-exploited. Therefore, this preliminary study is to investigate the existence of exploitable water resources that can balance the shortage of fresh water on this island. Site characterization data are obtained from island-wide geophysical surveys as well as small-scale tests performed in a study area formed by three deep (maximum depth to 560 m) vertical boreholes installed in mid-east Kinmen northeast to Taiwu Mountain. Vertical fracture frequency data indicate that the rock body is fractured with a spatially correlated pattern, from which three major fracture zones (depths 0–70, 330–360, and below 450 m) can be identified. Geologic investigations indicate that the deepest fracture zone is caused by the large-scale, steeply dipping Taiwushan fault. This fault may have caused a laterally extensive low-resistivity zone, a potential fractured aquifer, near Taiwu Mountain. The middle fracture zone is induced by the Taiwushan fault and intersects the fault approximately 21 m southeast of the study area below a depth of 350 m. Slug testing results yield fracture transmissivity varying from 4.8 × 10−7 to 2.2 × 10−4 m2/s. Cross-hole tests have confirmed that hydraulic connectivity of the deeper rock body is controlled by the Taiwushan fault and the middle fracture zone. This connectivity may extend vertically to the sedimentary aquifers through high-angle joint sets. Despite the presence of a flow barrier formed by doleritic dike at about 300 m depth, the existence of fresh as well as meteoric water in the deeper rock body manifests that certain flow paths must exist through which the deeper fractured aquifers can be connected to the upper rock body. Therefore, groundwater stored within the Taiwushan fault and the associated low-resistivity zone can be considered as additional fresh water resources for future exploitation.  相似文献   

8.
In EGS projects, fault zones are considered as the structures controlling deep flow at the reservoir scale. Using a large set of petrophysical properties (porosity, density, permeability, thermal conductivity [TC]) measured on cores collected along the EPS-1 borehole, a model of fault zone is proposed to describe them. A fault zone is a complex structure, showing different parts with different kinds of deformations and/or materials that could explain chemical and physical processes observed during fluid-rock interactions. The different parts composing the fault zone are: (1) the fault core or gauge zone; (2) the damage zone; (3) and the protolith. They are usually heterogeneous and show different physical properties. The damage zone is a potential high permeability channel and could become the main pathway for fluids if secondary minerals seal the fault core. Porosity is the lowest within the protolith, between 0.5 and 1%, but can go up to 15% in the fault zone. Permeability ranges from 10?20 m2 in the fresh granite to, at least, 10?15 m2 in the fault core, and TC ranges from 2.5 W K?1m?1 to 3.7 W K?1m?1. Finally, variations in specific surface are set over two orders of magnitude. If the lowest values usually characterize the fresh granite far from fault zones, physical properties could show variations spread over their whole respective ranges within these fault zones.  相似文献   

9.
 This paper presents a site-specific conceptual model of groundwater flow in fractured damage zones associated with faulting in a package of sedimentary rocks. The model is based on the results of field and laboratory investigations. Groundwater and methane gas inflows from fault-fracture systems in the West Elk coal mine, Colorado, USA, have occurred with increasing severity. Inflows of 6, 160 and 500 L s−1 discharged almost instantaneously from three separate faults encountered in mine workings about 460 m below ground level. The faults are about 600 m apart. The δ 2H and δ 18O compositions of the fault-related inflow waters and the hydrodynamic responses of each fault inflow indicate that the groundwaters discharge from hydraulically isolated systems. 14C data indicate that the groundwaters are as much as 10,500 years old. Discharge temperatures are geothermal (≈30°C), which could indicate upwelling from depth. However, calculations of geothermal gradients, analysis of solute compositions of groundwater in potential host reservoirs, geothermometer calculations, and results of packer testing indicate that the fractured groundwater reservoir is the Rollins Sandstone (120 m thick) directly beneath the coal seams. The packer test also demonstrates that the methane gas is contained in the coal seams. A geothermal gradient of 70–80°C km−1, related to an underlying intrusion, is probably responsible for the slightly elevated discharge temperatures. Large discharge volumes, as great as 8.2×105 m3 from the 14 South East Headgate fault (14 SEHG), rapid declines in discharge rates, and vertical and horizontal permeability (matrix permeability generally <0.006 Darcy) indicate fracture flow. An in-mine pumping test demonstrates that the 14 SEHG fault has excellent hydraulic communication with fractures 50 m from the fault. Aeromagnetic data indicate that the faults are tectonically related to an igneous body that is several thousand meters below the coal seams. Exploratory drilling has confirmed a fourth fault, and two additional faults are projected, based on the aeromagnetic data. The conceptual model describes a series of parallel, hydraulically separate groundwater systems associated with fault-specific damage zones. The faults are about 600 m apart. Groundwater stored in fractured sandstone is confined above and below by clayey layers. Received March 1999 / Revised, November 1999 / Accepted, December 1999  相似文献   

10.
Fault zone structure and lithology affect permeability of Triassic Muschelkalk limestone-marl-alternations in Southwest Germany, a region characterized by a complex tectonic history. Field studies of eight fault zones provide insights into fracture system parameters (orientation, density, aperture, connectivity, vertical extension) within fault zone units (fault core, damage zone). Results show decreasing fracture lengths with distances to the fault cores in well-developed damage zones. Fracture connectivity at fracture tips is enhanced in proximity to the slip surfaces, particularly caused by shorter fractures. Different mechanical properties of limestone and marl layers obviously affect fracture propagation and thus fracture system connectivity and permeability. Fracture apertures are largest parallel and subparallel to fault zones and prominent regional structures (e.g., Upper Rhine Graben) leading to enhanced fracture-induced permeabilities. Mineralized fractures and mineralizations in fault cores indicate past fluid flow. Permeability is increased by the development of hydraulically active pathways across several beds (non-stratabound fractures) to a higher degree than by the formation of fractures interconnected at fracture tips. We conclude that there is an increase of interconnected fractures and fracture densities in proximity to the fault cores. This is particularly clear in more homogenous rocks. The results help to better understand permeability in Muschelkalk rocks.  相似文献   

11.
Field measurements were made of 1717 mineral-filled veins in the damage zone of an active dextral strike-slip fault zone in Iceland. Most veins are composed of quartz, chalcedony and zeolites, strike roughly parallel or perpendicular to the fault zone, and are members of dense palaeo-fluid transporting networks. A common vein frequency in these networks is 10 veins per metre. Cross-cutting relationships indicate that 79% of the veins are extension (mode I) cracks and 21% are shear cracks. The apertures of most veins, measured as mineral-fill thicknesses, are from 0.1 to 85 mm, and the aperture frequency distribution is a power law. The outcrop trace lengths of 384 veins (of the 1717) could be measured accurately. These 384 veins are mostly small and range in length from 2.5 to 400 cm, in aperture from 0.01 to 0.9 cm, and have an average length/aperture ratio of about 400. Simple analytical models are derived and used to make rough estimates of the volumetric flow rates in hydrofractures of dimensions equal to those of typical veins. The results indicate that volumetric flow rates for a horizontal fracture and a vertical fracture in a rigid (non-deforming) host rock would be around 1.5×10−4 and 8.9×10−4 m3s−1, respectively. The volumetric flow rate in a vertical fracture of equal size but in a deforming host rock, with buoyancy added to the pressure gradient, is around 1.3×10−3 m3s−1. Thus, vertical fluid transport is favoured under these conditions.  相似文献   

12.
 Two multitracer tests performed in one of the major cross-fault zones of the Lange Bramke basin (Harz Mountains, Germany) confirm the dominant role of the fault zone in groundwater flow and solute transport. Tracers having different coefficients of molecular diffusion (deuterium, bromide, uranine, and eosine) yielded breakthrough curves that can only be explained by a model that couples the advective–dispersive transport in the fractures with the molecular diffusion exchange in the matrix. For the scale of the tests (maximum distance of 225 m), an approximation was used in which the influence of adjacent fractures is neglected. That model yielded nearly the same rock and transport parameters for each tracer, which means that the single-fracture approximation is acceptable and that matrix diffusion plays an important role. The hydraulic conductivity of the fault zone obtained from the tracer tests is about 1.5×10–2 m/s, whereas the regional hydraulic conductivity of the fractured rock mass is about 3×10–7 m/s, as estimated from the tritium age and the matrix porosity of about 2%. These values show that the hydraulic conductivity along the fault is several orders of magnitude larger than that of the remaining fractured part of the aquifer, which confirms the dominant role of the fault zones as collectors of water and conductors of fast flow. Received, April 1997 Revised, January 1998, August 1998 Accepted, August 1998  相似文献   

13.

Coal mining has serious impacts on local environment, including damage to the land and soil by subsidence, damage to ground-water systems through the fracturing and subsiding of overlying rocks, contamination of surface waters with acid mine drainage, and pollution of the atmosphere by release of toxic gases. The damage to ground water and its consequent impacts on the regional environment is the core of research of the coal mining from the perspective of environment protection. The present paper focuses on the changes of surface vegetation coverage, the pollutants released from pit coal power plants, and the damages to the ground aquifers induced by mining activities in arid Eastern Junggar coalfield of China. At first, the authors investigated the changes of surface vegetation coverage, since mining began in the 2000s using Landsat data. Results show that the low surface vegetation coverage (grade 1 plus grade 2) in the southern part of the region decreased from 11.62?×?108 m2 in 2003 to 9.57?×?108 m2 in 2017 (?17.6%), while it increased from 11.58?×?108 m2 in 2003 to 12.70?×?108 m2 in 2017 (+?9.7%) in the eastern part. The high surface vegetation coverage (grade 3 plus grade 4) in the southern part increased from 1.94?×?108 m2 in 2003 to 4.00?×?108 m2 in 2017 (+?106.2%), while it decreased from 4.39?×?108 m2 in 2003 to 3.26?×?108 m2 in 2017 (?25.74%) in the eastern part. The data of annual precipitation during the same period in this area show that the changes of surface vegetation coverage have less relationship with the annual precipitation, which indicates that the mining activities is probably the major factor for that. Second, a statistic of air pollutants generated from pit coal power plants was made based on data of references. Results show that the estimated gaseous pollutant emissions increased as 865.23 tons of smoke particles, 5940.73 tons of SO2, and 7584.48 tons of NO2 in 2013, which increased rapidly with 9.73 times the smoke particle, 21.69 times the SO2, and 9.24 times the NO2 than that of 2007. And then, the physical and numerical simulation of the damage of mining activities to aquifers was made to show the permeability of the reference points of overlying aquifers varies associated with mining activities. Results show that the porous rock matrix permeability has a negative relationship with fluctuation during mining, while the fracture permeability shows a positive one. Finally, a case investigation in southern area surrounding this coalfield was illustrated. Result shows that the local ground-water level decreased by 16 m difference from the altitude level of?+?774 m in 2003 to?+?758 m in 2013. Data and results from this study presented the already and the potential pollutions and damages to local environment induced by the mining activities in this region.

  相似文献   

14.
碳酸盐岩断裂破碎带结构、分布与发育机制   总被引:1,自引:0,他引:1  
断裂带通常包括狭窄的断层核与宽阔的破碎带,并对岩石物理及其水力学、流体与渗透性具有重要作用。根据断裂破碎带结构的差异,将碳酸盐岩断层核划分为颗粒支撑、基质支撑与胶结支撑等3种类型,将碳酸盐岩破碎带划分碎裂带与裂缝带。不同类型碳酸盐岩断层核与破碎带形成多种类型组合,并造成断裂破碎带多种复杂的渗流结构。通过井一震资料的结合,可以判识沉积盆地内部较宽的碳酸盐岩断裂破碎带,其宽度一位移关系可以指示断裂破碎带的不同生长方式与机制。复杂内部结构、多期构造成岩作用与non-Andersonian破裂机制可能导致碳酸盐岩断裂破碎带的异常生长,也是碳酸盐岩断裂破碎带机理研究的重要方向。  相似文献   

15.
The rate of aerobic oxidation of methane was calculated based on average profiles of the tritiumhelium age of the Baikal waters and concentrations of the dissolved methane in the water column. In the deep lake zone (>200 m), the intensity of oxidation vertically decreases and is (2–0.3) × 10?2 nl CH4l?1 days?1 in southern and central Baikal and (2.8–1.0) × 10?2 nl CH4 l?1 days?1 in northern Baikal. The effective coefficient of the oxidation rate in the lake depressions is 3.6 × 10?4, 3.3 × 10?4, and 3.7 × 10?4 days?1, respectively. At current methane concentrations in the water column, about 80 t of methane is oxidized per year. Oxidation of the dissolved methane in the water column was estimated at a possible increase of its concentration.  相似文献   

16.
Experiments reproducing the development of bimetasomatic zoning in the CaO-MgO-SiO2-H2O-CO2 system were conducted at elevated P-T parameters with the use of samples of naturally occurring quartzdolomite and calcite-serpentinite rocks. In order to maintain mass transfer exclusively via the diffusion-controlled mechanism, we used the method of the ensured compaction of the cylindrical sample surface with a thin-walled gold tube. In the course of the experiments, a single diopside zone ~2.5 × 10?5 m thick was obtained at the quartz-dolomite interface at T = 600°C, $P_{H_2 O + CO_2 } $ = 200 MPa, and $X_{CO_2 } $ = 0.5 for 25–40 days and a succession of metasomatic zones at T = 750°C, $P_{H_2 O + CO_2 } $ = 300 MPa, and $X_{CO_2 } $ = 0.4 for 48 days. The metasomatic zones were as follows (listed in order from quartz to dolomite): wollastonite ‖ diopside ‖ tremolite ‖ calcite + forsterite; with the average width of the diopside zone equal to ~1.3 × 10?5 m and the analogous part of the wollastonite zone equal to ~2.6 × 10?5 m. Two zones (listed in order from calcite to serpentine) diopside and diopside-forsterite (the average widths of these zones were ~6 × 10?4 and ~8 × 10?4 m, respectively) were determined to develop at contact between serpentine and calcite during experiments that lasted 124 days at T = 500°C, $P_{H_2 O + CO_2 } $ = 200 MPa, and $X_{CO_2 } $ = 0.2–0.4. In the former and latter situations, the growth rate of the zoning ranged between 3.1 × 10?12 and 1.2 × 10?11 m/s and between 5.6 × 10?11 and 7.5 × 10?11 m/s, respectively. The higher growth rate in the latter case can be explained by the higher water mole fraction in the fluid, with this water released during serpentinite decomposition in the experiments. The development of the only diopside zone in the experiments modeling the interaction of quartz and dolomite at T = 600–650°C and $P_{H_2 O + CO_2 } $ = 200 MPa is in conflict with theoretical considerations underlain by the Korzhinskii-Fisher-Joesten model. The interaction of quartz and dolomite in the CaO-MgO-SiO2-CO2-H2O system at the P-T- $X_{CO_2 } $ parameters specified above should be attended by the origin of a number of reaction zones consisting of various proportions of talc, forsterite, tremolite, diopside, and calcite. The saturation of the fluid with respect to these minerals was likely not reached, and this resulted in the degeneration of the respective stability fields in the succession of zones. Conceivably, this was related to the insufficient rates of quartz and dolomite dissolution and the relatively low diffusion rates of the dissolved species in the low-permeable medium. In the experiments with interacting calcite and serpentine, the zoning calcite ‖ diopside ‖ diopside + forsterite ‖ serpentine developed in its complete form, in agreement with the theory. Equilibrium was likely achieved in these experiments due to the higher diffusion coefficients.  相似文献   

17.
Compacted soil–bentonite liners, consisting of a sandy soil mixed with bentonite as backfill, are used extensively as engineered barriers for contaminant containment. This paper studies the valorization of local materials containing calcareous sand, tuff obtained from Laghouat region (in the South Algeria), to associate with bentonite in order to improve their hydraulic characteristics for use as landfill liner material. Firstly, a geotechnical characterization of mixtures chooses from a fixed percentage to 10% bentonite and different percentages of calcareous sand and tuff so that they are complementary to 90% by not 10%. Thereafter, the determination of saturated hydraulic conductivity at falling-head permeability (Kv) and oedometer (Kid, indirect Measure) tests of all compacted mixtures at Optimum Normal Proctor have been carried out using both permeates by tap water and a landfill leachate in order to simulate long-term conditions. The results showed that the saturated hydraulic conductivity of tap water is relatively lower than the one saturated by leachate in the falling-head test, unlike the oedometer test. The B10CS20T70 mixture has satisfied the hydraulic conductivity criterion of bottom barriers (i.e. water permeated: kv20° = 1.97 × 10?9 and kid from 7 × 10?9 to 1.83 × 10?10 < 10?9m/s; leachate permeated: kv20° = 2.91 × 10?9 and kid from 7 × 10?9 at 1.44 × 10?10 < 10?9 m/s). Finally, a comparison between direct measurements of the saturated hydraulic conductivity by triaxial (Kd) test and oedometer test (Kid) in the range of effective stress applied 100–800 kPa led to propose equations of correlations between these two methods. In conclusion, adopted formulation B10CS20T70 perfectly meets the regulatory requirements in force and constitutes an economic product based on available local materials for engineers barriers.  相似文献   

18.
Faults in continental flood basalt sequences potentially control subsurface fluid flow. We present field and microstructural observations from fault zones cutting interlayered basaltic volcaniclastic-crystalline sequences within the North Atlantic Igneous Province. Fractures likely initiate within lava units, before linking through the volcaniclastic units. Through-going faults show refraction, with subvertical faults in the lavas joined to variably inclined faults in the volcaniclastic layers. At >1.0 m displacement, volcaniclastic units are progressively dragged into the fault plane forming a smear. Volcaniclastic sandstones deform by flow. Claystones fracture, and are incorporated into smears as breccia. Experimentally measured host and fault rock sample permeabilities, at aquifer to reservoir pressures (i.e., 10–90 MPa; ∼0.3–3.0 km depth) show fault rocks from low displacement faults have relatively low permeability (10−17–10−20 m2); fault rocks from higher displacement structures have comparatively high permeability (10−15–10−17 m2). Our observations suggest that permeability is determined by the opposing influences of clay mineralization, which decreases permeability, versus the development of interconnected, higher permeability zeolite veins. Brecciation and the formation of zeolite vein networks within claystone smears results in high permeability. Zeolite veins in volcaniclastic units form poorly-connected, spaced sets, parallel to the slip plane, hence sequence permeability remains low.  相似文献   

19.
 The Middle Miocene Tobe hornfels in the Sanbagawa metamorphic belt, western Shikoku, southwest Japan, is characterized by an abnormally steep metamorphic gradient compared with other hornfelses associated with intrusive bodies. The basic hornfels, originally Sanbagawa greenschist rocks, is divided into the following three metamorphic zones: plagioclase, hornblende, and orthopyroxene. The plagioclase zone is defined by the appearance of calcic plagioclase, the hornblende zone by the assemblage of hornblende+calcic plagioclase+quartz, and the orthopyroxene zone is characterized by the assemblage of orthopyroxene + clinopyroxene + plagioclase + quartz. Calcic amphibole compositions change from actinolite to hornblende as a result of the continuous reactions during prograde metamorphism. Petrographical and thermometric studies indicate a metamorphic temperature range of 300–475°C for the plagioclase zone, 475–680°C for the hornblende zone, and 680–730°C for the orthopyroxene zone. The temperature gradient based on petrological studies is approximately 5°C/m, which is unusually high. Geological and petrological studies demonstrate that the hornfelses were formed by the focusing of high-temperature fluids through zones of relatively high fracture permeability. The steep thermal gradient in the Tobe hornfels body is consistent with a large fluid flux, greater than 8.3 × 10–7 m3 m–2S–1, over the relatively short duration of metamorphism, approximately 100 years. Received: 10 October 1995 / Accepted: 28 May 1996  相似文献   

20.
Fluid flows in consolidated porous media of volcanic origin are being investigated to support such diverse efforts as the modeling of thermal/outgassing phenomena at Mount St. Helens and the hydrological modeling of tuffaceous rocks in support of the Department of Energy’s (DOE) Nevada Nuclear Waste Storage Investigations Project An experimental apparatus was designed and built to allow water-saturated permeabilities as low as 10−18 m2 to be measured on cores of diameter 5 cm and length 10 cm under steady-state flow conditions. This same apparatus can also be utilized in a transient (pressure-decay) mode in order to measure permeabilities several orders of magnitude lower than the steady-state limit. Tests were conducted on samples of pumice, fractured welded tuff, and welded tuff, representing a permeability range of seven orders of magnitude Pumice was found to have a permeability of ∼3×10−12 m2, sufficiently high to allow the complete Darcy-to-Ergun regime to be investigated Welded (unfractured) tuff was tested in the transient mode, yielding a permeability of ∼5×10−19 m2. Two, long-time-scale, steady-flow experiments were conducted on a core of welded tuff containing a single, through-going fracture. For the first experiment, the core was an integral cylinder containing a naturally occurring fracture. For the second experiment, the core was separated into two pieces along the existing fracture plane, then rejoined. Effects of essentially constant, as well as rapidly varied, circumferential stress were studied in both tests. Results showed core permeability to decay to 2×10−18 m2 in both cases, independent of the initial fracture state (closed versus open). With a naturally occurring fracture, core permeability decreased by a factor of 2 over a 200-h test period. With an initially open fracture, core permeability decreased by a factor of 4 under the influence of a comparable 200-h load-time history, after 700 h of testing, core permeability was reduced by an order of magnitude from its initial level. Final effective hydraulic fracture aperture was calculated to be 10−6 m, corresponding to a calculated effective fracture permeability of 10−13 m2 Fracture flow was thus estimated to account for 80% of the total flow rate through this core under final test conditions.  相似文献   