首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
近断层地震动中长周期、短持时和高能量的加速度脉冲将对高层摩擦摆基础隔震结构的减震性能产生不利影响,考虑土-结构相互作用(SSI效应)后的隔震结构将产生动力耦合效应,可能进一步放大隔震结构地震响应。为此,通过一幢框架-核心筒高层摩擦摆基础隔震结构的非线性地震响应分析,考察近断层脉冲型地震动作用下框架-核心筒摩擦摆基础隔震结构的层间位移角、楼层加速度和隔震层变形等响应规律,揭示隔震体系的损伤机理。基于集总参数SR (sway-rocking)模型,分析不同场地类别与不同地震动类型对隔震体系动力响应影响规律。结果表明:高层摩擦摆基础隔震结构在近断层脉冲型地震动作用下的减震效果相比普通地震动减震效果变差,楼层剪力、层间位移角和隔震层变形等超越普通地震动作用下的1.5倍;对于Ⅲ和Ⅳ类场地类别,考虑SSI效应使隔震结构的地震响应进一步放大,弹塑性层间位移角随着土质变软增大尤为明显。  相似文献   

2.
This paper presents a non‐linear, kinematic model for triple friction pendulum isolation bearings. The model, which incorporates coupled plasticity and circular restraining surfaces for all sliding surfaces, is capable of capturing bi‐directional behavior and is able to explicitly track the movement of each internal component. The model is general so that no conditions regarding bearing properties, which effect the sequence of sliding stages, are required for the validity of the model. Controlled‐displacement and seismic‐input experiments were conducted using the shake table at the University of California, Berkeley to assess the fidelity of the proposed model under bi‐directional motion. Comparison of the experimental data with the corresponding results of the kinematic model shows good agreement. Additionally, experiments showed that the performance of TFP bearings is reliable over many motions, and the behavior is repeatable even when initial slider offsets are present. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
After an earthquake, non‐negligible residual displacements may affect the serviceability of a base isolated structure, if the isolation system does not possess a good restoring capability. The permanent offset does not affect the performance unless the design is problematic for utilities, also considering possible concerns related to the maintenance of the devices. Starting from experimental and analytical results of previous studies, the restoring capability of Double Concave Friction Pendulum bearings is investigated in this paper. A simplified design suggestion for the estimation of maximum expected residual displacements for currently used friction pendulum systems is then validated. The study is based on controlled‐displacement and seismic input experiments, both performed under unidirectional motion. Several shaking table tests have been carried out on a three‐dimensional isolated specimen structure. The same sequence of seismic inputs was applied considering three different conditions of sliding surfaces corresponding to low, medium and high friction. The accumulation of residual displacements is also investigated by means of nonlinear dynamic analysis. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

4.
层间滑移隔震结构地震作用有限元分析   总被引:4,自引:4,他引:0       下载免费PDF全文
将二硫化钼作为摩擦材料设计出一种带限位器的滑移隔震支座。根据多层框架结构变形的特点,给出适用于滑移框架隔震结构的计算模型,推导出层间滑移隔震结构的运动方程。运用SAP2000有限元软件建立一层间滑移框架隔震结构的有限元模型,对比分析El Centro地震波下摩擦系数和隔震层位置不同时隔震结构的地震反应。结果表明,上部结构的动力反应随摩擦系数的增加而不断增大,滑移隔震结构的减震效果逐渐减弱,但隔震层的滑移量却在不断减小;摩擦系数的选取应综合考虑减震效果和隔震层滑移量两个因素。随着隔震层的增高,结构的加速度反应和层间位移反应整体上呈增大趋势,隔震效果不断减弱,且隔震层的加速度值下部层比上部层要大得多,一层隔震和三层隔震时的变形主要集中于隔震层,而五层隔震时结构层间位移并未出现突变,说明隔震层设置在较高位置处对结构体系的影响较小。  相似文献   

5.
通过对隔震结构进行非线性动力响应分析,分别研究地震动参数和支座参数对结构地震响应的影响。首先,建立铅芯橡胶支座基础隔震结构的非线性运动方程;然后,以人工合成脉冲型地震动作为输入,运用MATLAB进行编程并求解结构在脉冲型地震动作用下的地震响应;最后,分别研究速度脉冲周期、支座屈服力、屈服后与屈服前的刚度比对隔震支座最大位移和上部结构层间位移的影响。研究结果表明,脉冲周期对结构地震响应影响很大,在进行隔震设计时应使结构自振周期远离脉冲周期;支座刚度比对结构地震响应影响较大,在进行支座选型时应重点关注;支座屈服力对支座位移的影响显著,屈服力越大,支座位移越小。  相似文献   

6.
<正>A theoretical model of a friction pendulum system(FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures.An equation of motion of the lattice shell with FPS bearings is developed.Then, seismic isolation studies are performed for both double-layer and single-layer lattice shell structures under different seismic input and design parameters of the FPS.The influence of frictional coefficients and radius of the FPS on seismic performance are discussed.Based on the study,some suggestions for seismic isolation design of lattice shells with FPS bearings are given and conclusions are made which could be helpful in the application of FPS.  相似文献   

7.
In this study, a series of shaking table tests are carried out on scaled models of two seismically isolated highway bridges to investigate the effect of rocking motion and vertical acceleration on seismic performance of resilient sliding isolators. In addition, performance of RSI is compared with system having solely natural rubber bearings. Test results show that variation of normal force on sliders due to rocking effect and vertical acceleration makes no significant difference in response of RSI systems. In addition, analytical response of prototype isolated bridge and the model used in experiments is obtained analytically by using non‐linear model for isolation systems. It is observed that for seismically isolated bridges, dynamic response of full‐scale complex structures can be predicted with acceptable accuracy by experiments using a simple model of the structure. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

8.
Storage tanks are vulnerable to earthquakes, as numerous major earthquakes have demonstrated. The trend of recent revisions to make seismic design criteria for large‐scale industrial storage tanks increasingly stringent has made development of cost‐effective earthquake‐resistant design and retrofit techniques for industrial tanks imperative. This study assesses the feasibility of seismic base isolation for making liquid‐filled storage tanks earthquake resistant. The sliding‐type friction pendulum seismic (FPS) bearings are considered rather than the elastomeric bearings because the dynamic characteristics of an FPS‐isolated tank remain unchanged regardless of the storage level. This work has devised a hybrid structural‐hydrodynamic model and solution algorithm, which would permit simple, accurate and efficient assessment of the seismic response of rigid cylindrical storage tanks in the context of seismic isolation. Extensive numerical simulations confirm the effectiveness of seismic base isolation of rigid cylindrical tanks using FPS bearings. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

9.
The seismic performance of the Bolu Viaduct in the Duzce, Turkey, earthquake of November 1999 was studied via a non‐linear, time‐history analysis of a multi‐degree of freedom model. The viaduct had a seismic isolation system consisting of yielding‐steel energy dissipation units and sliding pot bearings. The Duzce earthquake caused a surface rupture across the viaduct, which resulted in excessive superstructure movement and widespread failure of the seismic isolation system. The effect of the rupture was modeled by a static, differential ground displacement in the fault‐parallel direction across the rupture. The ground motions used in the analysis contain common near‐fault features including a directivity pulse in the fault‐normal direction and a fling step in the fault‐parallel direction. The analysis used a finite element package capable of modeling the mechanical behavior of the seismic isolation system and focused on the structural response of a 10‐span module of the viaduct. This analysis showed that the displacement of the superstructure relative to the piers exceeded the capacity of the bearings at an early stage of the earthquake, causing damage to the bearings as well as to the energy dissipation units. The analysis also indicated that shear keys, both longitudinal and transverse, played a critical role in preventing collapse of the deck spans. Published in 2004 by John Wiley & Sons, Ltd.  相似文献   

10.
In this paper, the responses of multi‐degree‐of‐freedom (MDOF) structures on sliding supports subjected to harmonic or random base motions are investigated. Modeling of the friction force under the foundation raft is accomplished by using a fictitious rigid link which has a rigid–perfectly plastic material. This will result in identical equations of motion for the sliding structure, both in the sliding and non‐sliding (stick) phases which greatly simplifies the implementation of the method into a numerical algorithm. In this model the phase transition times are determined with high accuracy. This has two advantages: first, it prevents the so‐called high‐frequency oscillation of the relative velocity at the end of the sliding phase, and second, the time steps can be selected so that each falls exactly within one phase of motion. In this case, the stiffness matrix of the structure remains constant throughout each phase and thus any method for solving the non‐linear differential equations of motion (e.g. Newmark method) can be used without iteration. The proposed method, besides its simplicity, is numerically very efficient and considerably reduces the required analysis time compared with most of the other methods. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

11.
While isolation can provide significantly enhanced performance compared to fixed‐base counter parts in design level or even maximum considered level earthquakes, there is still uncertainty over the performance of isolation systems in extreme events. Researchers have looked at component level stability of rubber bearings and on the effect of moat impact on behavior of structures isolated on general bilinear isolators. However, testing of triple friction pendulum (TFP) sliding bearings has not been done dynamically or incorporated into a building system. Here, one‐third scale laboratory tests were conducted to on a 2‐story 2‐bay TFP‐isolated structure. Input motions were increasingly scaled until failure occurred at the isolation level. As the superstructure was designed with a yield force equivalent to the force of the bearing just at their ultimate displacement capacity, there was minimal yielding. A numerical model is presented to simulate the isolated building up to and including bearing failure. Forces transferred to the superstructure in extreme motions are examined using both experimental and numerical data. Additionally, the effect of the hardening stage of the TFP bearing is evaluated using the numerical model, finding slight benefits.  相似文献   

12.
摩擦摆基础隔震结构双向地震反应分析   总被引:6,自引:0,他引:6  
采用双向耦合力学模型模拟摩擦摆支座的双向耦合效应,对摩擦摆基础隔震结构进行了单向和双向地震反应对比分忻,分析表明在双向地震作用下结构各层的加速度反应较小,隔震层的层间位移较大,而上部结构的层间位移较小,并且在双向地震作用下,支座的最大位移明显大于单向地震作用时的支座最大位移,因而应考虑双向地震作用对摩擦摆基础隔震结构地震反应和隔震支座性能的影响。  相似文献   

13.
The seismic response of a multi‐span continuous bridge isolated with novel superelastic‐friction base isolator (S‐FBI) is investigated under near‐field earthquakes. The isolation system consists of a flat steel‐Teflon sliding bearing and a superelastic NiTi shape memory alloy (SMA) device. The key design parameters of an S‐FBI system are the natural period of the isolated bridge, the yielding displacement of the SMA device, and the friction coefficient of the sliding bearings. The goal of this study is to obtain optimal values for each design parameter by performing sensitivity analysis of a bridge isolated by an S‐FBI system. First, a three‐span continuous bridge is modeled as two‐degrees‐of‐freedom with the S‐FBI system. A neuro‐fuzzy model is used to capture rate‐ and temperature‐dependent nonlinear behavior of the SMA device. Then, a set of nonlinear time history analyses of the isolated bridge is performed. The variation of the peak response quantities of interest is shown as a function of design parameters of the S‐FBI system and the optimal values for each parameter are evaluated. Next, in order to assess the effectiveness of the S‐FBI system, the response of the bridge isolated by the S‐FBI system is compared with the response of the non‐isolated bridge and the same bridge isolated by pure‐friction (P‐F) sliding isolation system. Finally, the influence of temperature variations on the performance of the S‐FBI system is evaluated. The results show that the optimum design of a bridge with the S‐FBI system can be achieved by a judicious specification of design parameters. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Coulomb damping can be utilized effectively to reduce the dynamic response of structures subjected to seismic ground motions. To activate this damping, some parts of a vibrating structure are allowed to slide at rough interfaces. The dynamic response of structures provided with sliding interfaces at the base, between a floor slab and frame and in the cross bracings of a frame has been examined recently. In this paper, a simple slab sliding system provided with a spring to introduce a recovery mechanism and to reduce the sliding displacement requirement for low frequency structures has been examined. The equations of motion for this system are developed. An approach is presented to solve these coupled equations for earthquake induced ground motions. Structures with varying frequency and friction characterisics are considered and the numerical results are presented in response spectrum form. It is observed that, in low frequency structures, provision of a rather weak spring can reduce the sliding displacement requirements without significantly increasing the forces in the supporting frame and the acceleration input to supported secondary systems.  相似文献   

15.
利用实体软钢棒作为消能限位装置,将一种摩擦性能优良的二硫化钼材料作为隔震支座的滑移材料,提出并制作了一种可以应用于框架结构既能隔震又可以消能的新型摩擦滑移隔震装置。探讨了其设计方法和应用方法,并对安装了该新型摩擦滑移隔震装置的一相似比为1:5的5层框架结构模型进行了振动台试验,测试了框架结构在单向地震波作用下的地震反应规律,分析了摩擦滑移隔震结构的加速度反应、层间剪力反应、隔震层滑移量及隔震层剪力的变化规律。结果表明:一般情况下当设防烈度为8度,Ⅱ类场地时,该隔震结构的加速度响应可降低50%左右,层间剪力响应可降低50%左右,减震效果比较明显。另外,只要确定合理的构造方案和实施方案,这种新型摩擦滑移隔震装置就能满足框架结构的隔震减震要求,可应用于实际工程结构中。  相似文献   

16.
Base isolation has been established as the seismic design approach of choice when it comes to protecting nonstructural contents. However, while this protection technology has been widely shown to reduce seismic demands on attached oscillatory equipment and contents (EC), its effectiveness in controlling the response of freestanding EC that are prone to sliding has not been investigated. This study examines the seismic behavior of sliding EC inside base‐isolated buildings subjected to broadband ground motions. The effect of isolation system properties on the response of sliding EC with various friction coefficients is examined. Two widely used isolation models are considered: viscously damped linear elastic and bilinear. The study finds isolation to be generally effective in reducing seismic demands on sliding EC, but it also exposes certain situations where isolation in fact increases demands on EC, most notably for low friction coefficients and high earthquake intensities. Damping at the isolation level is effective in controlling the EC sliding displacements, although damping over about 20% is found to be superfluous. The study identifies a physically motivated dimensionless intensity measure and engineering demand parameter for sliding equipment in base‐isolated buildings subjected to broadband ground motions. Finally, the paper presents easy‐to‐use design fragility curves and an example that illustrates how to use them. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
Although the behavior of friction sliding bearings is well understood, the failure behavior has not been thoroughly investigated. However, predicting and understanding the failure of bearings is an important key in designing isolated structures to minimize their collapse in extreme events, and thus, this study is critical. Because of its relative simplicity and particular availability in certain markets, the failure of the double friction pendulum (DFP) bearing at its physical displacement limit is investigated. The bearing is modeled with a rigid body model including inertia for each of the bearing components. A nonlinear viscoelastic impact model is included to simulate the impact between bearing components. As isolation systems are particularly vulnerable to long‐period excitations, analytical pulses are used as input excitations to investigate the influences of pulse parameters on the failure of DFP. The influences of DFP design parameters are investigated as well. To confirm that the response to the analytical pulses correctly represents the behavior under long‐period ground motions, wavelet analysis to is performed on 14 pairs of pulse‐type ground motion records to extract their pulses, and the failure prediction made from the extracted analytical pulse is compared with the failure from the real ground motions. It is found that using the extracted pulses provides a good estimation for the failure prediction of the ground motions. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
实际地震具有多维特性,只考虑水平向作用往往不够真实全面,而且远场长周期地震动不同于普通地震动,具有周期长、持时长、低频成份丰富等特征,对周期较大的隔震类结构会产生不利影响,在考虑SSI效应(soil-structure interaction, SSI)中尤为复杂,需深入探讨。基于此,建立大底盘层间隔震结构,在三维地震动激励下,探讨普通地震与远场长周期地震对层间隔震结构的不同影响,并分析考虑SSI效应对结构的不同程度影响。结果表明:三维地震下,远场长周期对层间隔震结构产生的地震响应远大于普通地震;考虑SSI效应时,随着土体变软,结构响应增大;针对传统水平隔震支座,在三维远场长周期地震下出现层间位移角和支座位移超限问题,设置三维隔震支座,解决了超限问题,分析结果表明其隔减震效果明显优于传统水平隔震支座。  相似文献   

19.
A systematic method is developed for the dynamic analysis of the structures with sliding isolation which is a highly non-linear dynamic problem. According to the proposed method, a unified motion equation can be adapted for both stick and slip modes of the system. Unlike the traditional methods by which the integration interval has to be chopped into infinitesimal pieces during the transition of sliding and non-sliding modes, the integration interval remains constant throughout the whole process of the dynamic analysis by the proposed method so that accuracy and efficiency in the analysis of the non-linear system can be enhanced to a large extent. Moreover, the proposed method is general enough to be adapted for the analysis of the structures with multiple sliding isolators undergoing independent motion conditions simultaneously. The superiority of the proposed method for the analysis of sliding supported structures is verified by a three-span continuous bridge subjected to harmonic motions and real earthquakes. In addition, the side effect of excessive displacement of the superstructure induced by the sliding isolation is eliminated by replacing one of the roller supports on the abutments with hinge support. Therefore, both reductions in the forces of the substructure and the displacements of the superstructure can be achieved simultaneously. © 1998 John Wiley & Sons, Ltd.  相似文献   

20.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号