首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Experimental determination of the pressure and temperature controls on Ti solubility in quartz provides a calibration of the Ti‐in‐quartz (TitaniQ) geothermometer applicable to geological conditions up to ~ 20 kbar. We present a new method for determining 48Ti mass fractions in quartz by LA‐ICP‐MS at the 1 μg g?1 level, relevant to quartz in HP‐LT terranes. We suggest that natural quartz such as the low‐CL rims of the Bishop Tuff quartz (determined by EPMA; 41 ± 2 μg g?1 Ti, 2s) is more suitable than NIST reference glasses as a reference material for low Ti mass fractions because matrix effects are limited, Ca isobaric interferences are avoided, and polyatomic interferences at mass 48 are insignificant, thus allowing for the use of 48Ti as a normalising mass. Average titanium mass fraction from thirty‐three analyses of low temperature quartz from the Czech Erzgebirge is 0.9 ± 0.2 μg g?1 (2s) using 48Ti as a normalising mass and Bishop Tuff quartz rims as a reference material. The 2s average analytical uncertainty for individual analyses of 48Ti is 8% for 50 μm spots and 7% for 100 μm spots, which offers much greater accuracy than the 21–41% uncertainty (2s) incurred from using 49Ti as an analyte.  相似文献   

2.
We report homogeneity tests on large natural apatite crystals to evaluate their potential as U reference materials for apatite fission‐track (AFT) thermochronology by laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS). The homogeneity tests include the measurements of major element concentrations by electron probe microanalysis (EPMA), whereas for U concentration, isotope dilution (ID) ICP‐MS and laser ablation (LA) ICP‐MS were employed. Two apatite crystals are potential reference materials for LA‐ICP‐MS analysis: a 1 cm3 fraction of a Durango crystal (7.5 μg g?1 U) and a 1 cm3 Mud Tank crystal (6.9 μg g?1 U). The relative standard deviation (1 RSD) of the U concentration determined by ID‐ICP‐MS of both apatite crystals was ≤ 1.5%, whereas 1 RSD for the LA‐ICP‐MS results was better than 4%, providing sufficient homogeneity for fission‐track dating. The results on the U homogeneity for two different apatite samples are an important step towards establishing in situ dating routines for AFT analysis by LA‐ICP‐MS.  相似文献   

3.
The low‐Sr content (generally < 100 μg g?1) in clinopyroxene from peridotite makes accurate Sr isotopic determination by LA‐MC‐ICP‐MS a challenge. The effects of adding N2 to the sample gas and using a guard electrode (GE) on instrumental sensitivity for Sr isotopic determination by LA‐MC‐ICP‐MS were investigated. Results revealed no significant sensitivity enhancement of Sr by adding N2 to the ICP. Although using a GE led to a two‐fold sensitivity enhancement, it significantly increased the yield of polyatomic ion interferences of Ca‐related ions and TiAr+ on Sr isotopes. Applying the method established in this work, 87Sr/86Sr ratios (Rb/Sr < 0.14) of natural clinopyroxene from mantle and silicate glasses were accurately measured with similar measurement repeatability (0.0009–0.00006, 2SE) to previous studies but using a smaller spot size of 120 μm and low‐to‐moderate Sr content (30–518 μg g?1). The measurement reproducibility was 0.0004 (2s, n = 33) for a sample with 100 μg g?1 Sr. Destruction of the crystal structure by sample fusion showed no effect on Sr isotopic determination. Synthesised glasses with major element compositions similar to natural clinopyroxene have the potential to be adopted as reference materials for Sr isotopic determination by LA‐MC‐ICP‐MS.  相似文献   

4.
Germanium (Ge) exists at trace levels in the Earth's crust and is a powerful geochemical tracer of the silicon (Si) cycle. This study proposes a simple and reliable method for determining Ge contents in environmental samples using ICP‐MS. As Si and Ge have very similar chemical properties, we investigated the applicability of the chemical preparation procedure developed for Si isotopes for the determination of Ge in environmental samples. Advantages of this procedure are as follows: (a) efficient removal of the matrix and main interferences affecting Ge determinations by ICP‐MS, (b) a low limit of detection (6 ng l?1), (c) relative repeatability of approximately 3% obtained on 74Ge and (d) robustness and accuracy based on agreement within errors with the published Ge values for rock reference materials (BHVO‐2, AGV‐2 and BCR‐2). This procedure allowed revision of the Ge values of three soil reference materials (1.67 ± 0.09 μg g?1, 2.41 ± 0.18 μg g?1, 1.89 ± 0.10 μg g?1 for GBW 07401, GBW 07404 and GBW 07407, respectively) and proposal of a value for the plant reference material ERM‐CD281 (70 ± 3 μg g?1). This method provides a convenient procedure for determining Ge mass fractions in environmental samples and opens the possibility of coupling two tracers of the Si biogeochemical cycle with a single measurement procedure.  相似文献   

5.
Three synthetic reference glasses were prepared by directly fusing and stirring 3.8 kg of high‐purity oxide powders to provide reference materials for microanalytical work. These glasses have andesitic major compositions and are doped with fifty‐four trace elements in nearly identical abundance (500, 50, 5 µg g?1) using oxide powders or element solutions, and are named ARM‐1, 2 and 3, respectively. We further document that sector‐field (SF) ICP‐MS (Element 2 or Element XR) is capable of sweeping seventy‐seven isotopes (from 7Li to 238U, a total of sixty‐eight elements) in 1 s and, thus, is able to quantify up to sixty‐eight elements by laser sampling. Micro‐ and bulk analyses indicate that the glasses are homogeneous with respect to major and trace elements. This paper provides preliminary data for the ARM glasses using a variety of analytical techniques (EPMA, XRF, ICP‐OES, ICP‐MS, LA‐Q‐ICP‐MS and LA‐SF‐ICP‐MS) performed in ten laboratories. Discrepancies in the data of V, Cr, Ni and Tl exist, mainly caused by analytical limitations. Preliminary reference and information values for fifty‐six elements were calculated with uncertainties [2 relative standard error (RSE)] estimated in the range of 1–20%.  相似文献   

6.
A potential zircon reference material (BB zircon) for laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) U‐Pb geochronology and Hf isotope geochemistry is described. A batch of twenty zircon megacrysts (0.5–1.5 cm3) from Sri Lanka was studied. Within‐grain rare earth element (REE) compositions are largely homogeneous, albeit with some variation seen between fractured and homogeneous domains. Excluding fractured cathodoluminescence bright domains, the variation in U content for all analysed crystals ranged from 227 to 368 μg g?1 and the average Th/U ratios were between 0.20 and 0.47. The Hf isotope composition (0.56–0.84 g/100 g Hf) is homogeneous within and between the grains – mean 176Hf/177Hf of 0.281674 ± 0.000018 (2s). The calculated alpha dose of 0.59 × 1018 g?1 for a number of BB grains falls within the trend of previously studied, untreated zircon samples from Sri Lanka. Aliquots of the same crystal (analysed by ID‐TIMS in four different laboratories) gave consistent U‐Pb ages with excellent measurement reproducibility (0.1–0.4% RSD). Interlaboratory assessment (by LA‐ICP‐MS) from individual crystals returned results that are within uncertainty equivalent to the TIMS ages. Finally, we report on within‐ and between‐grain homogeneity of the oxygen isotope systematic of four BB crystals (13.16‰ VSMOW).  相似文献   

7.
This article presents new boron concentrations for nine geochemical reference materials (GS‐N, FK‐N, GL‐O, BX‐N, DT‐N, AN‐G, GH, Mica‐Fe, Mica‐Mg). After extraction by a modified pyrohydrolysis technique, boron concentrations were measured by ICP‐MS. The blank levels for the whole procedure were 0.091 ± 0.020 ng ml?1 or 14 ± 5 ng of boron in total. The method was first validated by measuring nine reference materials with known boron concentrations. The determined boron concentrations are all within the range of recommended or published values, which means that the yields were 100%, and show precisions below 10% for samples containing over 2 μg g?1 of boron.  相似文献   

8.
A laser ablation multi‐collector inductively coupled plasma‐mass spectrometry (LA‐MC‐ICP‐MS) method was developed to obtain precise and accurate Pb isotopic ratio measurements in low‐Pb materials (< 10 μg g?1) using a combination of Faraday cups and ion counters (FC–IC). The low abundance 204Pb (~ 1.4%) was collected using an IC. A NBS 981 standard solution was used to cross‐calculate the FC–IC gain and to investigate the signal response characteristics of the IC. A significant, continuous and linear decrease in the FC–IC gain was observed within 1 hr, but this drift could be corrected using the calibrator‐sample‐calibrator bracketing method. In addition, a non‐linear response of the IC used in this study was observed and corrected by a non‐linear correction algorithm, which was established by measuring a series of gravimetrically prepared NBS 981 standard solutions (NIST SRM 981). Compared with the conventional arrangement, the use of the newly designed X skimmer cone and Jet sample cone improved the signal intensities from Pb isotopes by a factor of 1.9. Compared with only Faraday cups, using a combination FC–IC array was found to enhance the measurement repeatability (RSD) of 20xPb/204Pb by approximately one order of magnitude when the 204Pb intensity was < 8 mV. Eight natural glasses and the NIST SRM 612 reference material glass (as a calibration material) were measured to evaluate the new protocol for Pb isotope determination. The analytical results were in agreement with the reference values within 2s measurement uncertainties. For MPI‐DING ATHO‐G (5.67 μg g?1 total Pb), KL2‐G (2.07 μg g?1 total Pb) and ML3B‐G (1.38 μg g?1 total Pb), the typical accuracies of 20xPb/204Pb were 0.09% of preferred values with precisions of < 0.33% (2RSD). The Pb isotope ratios in feldspars from granodiorite and within mafic microgranular enclaves (MMEs) from the Fangshan pluton, North China, were measured using the present method. The Pb isotopic compositions of feldspars from the whole host granodiorite show that that are radiogenic in the margin zone and gradually become less radiogenic. For the MMEs, the Pb isotopic compositions of feldspars are highly variable and overlap with those of the whole host granodiorite. For single‐grain feldspar, the strong rim‐core‐rim variations of the Pb isotopic compositions and trace elements are interpreted to have been generated via magma mixing. These results suggest that the Fangshan pluton underwent magma mixing of mantle‐derived mafic magmas with felsic magmas, and the proportion of the mafic magma influx decreased over time.  相似文献   

9.
Mass fractions of Sn and In were determined in sixteen geological reference materials including basaltic/mafic (BCR‐2, BE‐N, BHVO‐1, BHVO‐2, BIR‐1, OKUM, W‐2, WS‐E), ultramafic (DTS‐2b, MUH‐1, PCC‐1, UB‐N) and felsic/sedimentary reference materials (AGV‐2, JA‐1, SdAR‐M2, SdAR‐H1). Extensive digestion and ion exchange separation tests were carried out in order to provide high yields (> 90% for Sn, > 85% for In), low total procedural blanks (~ 1 ng for Sn, < 3 pg for In) and low analytical uncertainties for the elements of interest in a variety of silicate sample matrices. Replicate analyses (= 2–13) of Sn–In mass fractions gave combined measurement uncertainties (2u) that were generally < 3% and in agreement with literature data, where available. We present the first high‐precision In data for reference materials OKUM (32.1 ± 1.5 ng g?1), DTS‐2b (2.03 ± 0.25 ng g?1), MUH‐1 (6.44 ± 0.30 ng g?1) and PCC‐1 (3.55 ± 0.35 ng g?1) as well as the first Sn data for MUH‐1 (0.057 ± 0.010 μg g?1) and DTS‐2b (0.623 ± 0.018 μg g?1).  相似文献   

10.
We present in this article a rapid method for B extraction, purification and accurate B concentration and δ11B measurements by ID‐ICP‐MS and MC‐ICP‐MS, respectively, in different vegetation samples (bark, wood and tree leaves). We developed a rapid three‐step procedure including (1) microwave digestion, (2) cation exchange chromatography and (3) microsublimation. The entire procedure can be performed in a single working day and has shown to allow full B recovery yield and a measurement repeatability as low as 0.36‰ (± 2s) for isotope ratios. Uncertainties mostly originate from the cation exchange step but are independent of the nature of the vegetation sample. For δ11B determination by MC‐ICP‐MS, the effect of chemical impurities in the loading sample solution has shown to be critical if the dissolved load exceeds 5 μg g?1 of total salts or 25 μg g?1 of DOC. Our results also demonstrate that the acid concentration in the sample loading solution can also induce critical isotopic bias by MC‐ICP‐MS if chemistry of the rinsing‐, bracketing calibrator‐ and sample solutions is not thoroughly adjusted. We applied this method to provide a series of δ11B values of vegetal reference materials (NIST SRM 1570a = 25.74 ± 0.21‰; NIST 1547 = 40.12 ± 0.21‰; B2273 = 4.56 ± 0.15‰; BCR 060 = ?8.72 ± 0.16‰; NCS DC73349 = 16.43 ± 0.12‰).  相似文献   

11.
Matrix‐matched reference materials are necessary for accurate microbeam U‐Pb dating and Hf isotopic determination. This study introduces the RMJG rutile as a new potential reference material, which was separated from Palaeoproterozoic pelitic granulites collected in Hebei Province, China. LA‐ICP‐MS measurements indicate the RMJG rutile has extremely low Th (< 0.003 ± 0.01 µg g?1) and common Pb contents, but high Hf (102 ± 34 µg g?1), U (61 ± 11 µg g?1), and radiogenic Pb (~ 20 µg g?1) contents. Moreover, the rutile yields relatively constant U‐Pb ages and Hf isotopic data. The LA‐ICP‐MS analyses suggest that this rutile has a concordant U‐Pb age with a statistical mean 206Pb/238U and 207Pb/235U ages of 1749.9 ± 32.1 Ma and 1750.0 ± 26.4 Ma, respectively (2s), which are statistically indistinguishable from its ID‐TIMS ages (1750.6 ± 8.4 and 1750.1 ± 4.7 Ma). Precise determination of the 176Hf/177Hf ratio by MC‐ICP‐MS in solution mode (0.281652 ± 0.000006) is in good agreement with the statistical mean of the LA‐MC‐ICP‐MS measurements (0.28166 ± 0.00018). Therefore, the limited variations of RMJG U‐Pb age and Hf isotopic composition together with its extremely low common Pb and high Hf, U and Pb contents make it an ideal calibration and monitor reference material for LA‐ICP‐MS measurements.  相似文献   

12.
This study describes two methods (Procedures‐1 and ‐2) for the direct extraction of Au by an inorganic acid mixture (HClO4‐HBr‐HI‐aqua regia) from complex sample matrices. Standard PTFE jars at 200 °C were used to decompose test portions of 0.5–1 g, with subsequent precise and accurate analysis by ICP‐MS without any other preconcentration or separation. Procedure‐1 decomposed samples effectively without the necessity of leaching with HF and was developed for dust samples from e‐waste (electronic waste) processing; however, testing on geological reference materials showed very good results. The analyses of replicate decompositions (= 5) from both procedures yielded very good precision (< 5% RSD) for most of the reference materials. The accuracy achieved was better than ± 10%, with the exception of NIST SRM 2782 data from Procedure‐1. Two unknown samples of dust from e‐waste processing (P‐1 and VM‐1) exhibited elevated concentrations of Au (21.31–61.64 μg g?1) with precision better than 10% (= 5). The proposed techniques are simple, sensitive and sparing in the use of chemicals, and are designed for a variety of e‐waste dust samples. No significant influences were observed for the predicted spectral interferences on mass 197Au.  相似文献   

13.
Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission‐electron probe microanalysis (FE‐EPMA), laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and synchrotron micro X‐ray fluorescence spectroscopy (SR‐μ‐XRF). This study assesses the accuracy, precision and detection limits of these mostly non‐destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE‐EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA‐ICP‐MS analyses required larger gold particles (> 60 μm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA‐ICP‐MS measurements had lower detection limits, precision was lower than FE‐EPMA and SR‐μ‐XRF. The higher variability in absolute values measured by LA‐ICP‐MS, possibly due to micro‐inclusions, had to be critically assessed. Non‐destructive point analyses of gold alloys by SR‐μ‐XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE‐EPMA, but higher than those for elements measured by LA‐ICP‐MS.  相似文献   

14.
In this article, we document a detailed analytical characterisation of zircon M127, a homogeneous 12.7 carat gemstone from Ratnapura, Sri Lanka. Zircon M127 has TIMS‐determined mean U–Pb radiogenic isotopic ratios of 0.084743 ± 0.000027 for 206Pb/238U and 0.67676 ± 0.00023 for 207Pb/235U (weighted means, 2s uncertainties). Its 206Pb/238U age of 524.36 ± 0.16 Ma (95% confidence uncertainty) is concordant within the uncertainties of decay constants. The δ18O value (determined by laser fluorination) is 8.26 ± 0.06‰ VSMOW (2s), and the mean 176Hf/177Hf ratio (determined by solution ICP‐MS) is 0.282396 ± 0.000004 (2s). The SIMS‐determined δ7Li value is ?0.6 ± 0.9‰ (2s), with a mean mass fraction of 1.0 ± 0.1 μg g?1 Li (2s). Zircon M127 contains ~ 923 μg g?1 U. The moderate degree of radiation damage corresponds well with the time‐integrated self‐irradiation dose of 1.82 × 1018 alpha events per gram. This observation, and the (U–Th)/He age of 426 ± 7 Ma (2s), which is typical of unheated Sri Lankan zircon, enable us to exclude any thermal treatment. Zircon M127 is proposed as a reference material for the determination of zircon U–Pb ages by means of SIMS in combination with hafnium and stable isotope (oxygen and potentially also lithium) determination.  相似文献   

15.
A new natural rutile reference material is presented, suitable for U‐Pb dating and Zr‐in‐rutile thermometry by microbeam methods. U‐Pb dating of rutile R632 using laser ablation ICP‐MS with both magnetic sector field and quadrupole instruments as well as isotope dilution‐thermal ionisation mass spectrometry yielded a concordia age of 496 ± 2 Ma. The high U content (> 300 μg g?1) enabled measurement of high‐precision U‐Pb ages despite its young age. The sample was found to have a Zr content of 4294 ± 196 μg g?1, which makes it an excellent complementary reference material for Zr‐in‐rutile thermometry. Individual rutile grains have homogeneous compositions of a number of other trace elements including V, Cr, Fe, Nb, Mo, Sn, Sb, Hf, Ta and W. This newly characterised material significantly expands the range of available rutile reference materials relevant for age and temperature determinations.  相似文献   

16.
Advances in the quantification of rare earth elements (REE) at the micrometric scale in uranium oxides by laser ablation‐inductively coupled plasma‐mass spectrometry are described. The determination of the best analytical conditions was tested using a uranium oxide (Mistamisk) the concentrations of REE in which were previously estimated by other techniques. Comparison between the use of U or Pb as an internal standard clearly showed a diameter‐dependent fractionation effect related to Pb at small crater diameters (16 and 24 μm), which was not found for U. The quantification of REE contents in uranium oxide samples using both matrix‐matched (uranium oxide) and non‐matrix‐matched (NIST SRM 610 certified glass) external calibrators displayed no significant difference, demonstrating a limited matrix effect for REE determination by LA‐ICP‐MS. Moreover, no major interferences on REEs were detected. The proposed methodology (NIST SRM 610 as external calibrator and U as internal standard) was applied to samples from uranium deposits from around the world. The results showed that LA‐ICP‐MS is a suitable analytical technique to determine REE down to the μg g?1 level in uranium oxides at the micrometre scale and that this technique can provide significant insights into uranium metallogeny.  相似文献   

17.
The strong spectral interference between Br‐ and Al‐induced X‐ray lines hampers the utilisation of electron probe microanalysis (EPMA) for measuring Br mass fractions in Al‐bearing minerals and glasses. Through measuring Br‐free Al‐bearing materials, we established an EPMA method to quantify the overlap from AlKα on BrLβ, which can be expressed as a linear function of the Al2O3 content. The count rate of the BrLβ peak signal was enhanced by high beam currents and long measurement times. Application of this EPMA method to Al‐ and Br‐bearing materials, such as sodalite and scapolite, and to five experimental glasses yielded Br mass fractions (in the range of 250–4000 μg g?1) that are consistent with those measured by microbeam synchrotron X‐ray fluorescence (μ‐SXRF) spectrometry. The EPMA method has an estimated detection limit of ~ 100–300 μg g?1. We propose that this method is useful for measuring Br mass fractions (hundreds to thousands of μg g?1) in Al‐bearing minerals and glasses, including those produced in Br‐doped experiments. In addition, the natural marialitic scapolite (ON70) from Mpwapwa (Tanzania) containing homogeneously distributed high mass fractions of Br (2058 ± 56 μg g?1) and Cl (1.98 ± 0.03% m/m) is an ideal reference material for future in situ analyses.  相似文献   

18.
We present an open‐source algorithm in Mathematica application (Wolfram Research) with a transparent data reduction and Monte Carlo simulation of systematic and random uncertainties for U‐Th geochronometry by multi‐collector ICP‐MS. Uranium and thorium were quantitatively separated from matrix elements through a single U/TEVA extraction chromatography step. A rigorous calibrator‐sample bracketing routine was adopted using CRM‐112A and IRMM‐035 standard solutions, doped with an IRMM‐3636a 233U/236U ‘double‐spike’ to account for instrumental mass bias and deviations of measured isotope ratios from certified values. The mean of 234U/238U and 230Th/232Th in the standard solutions varied within 0.42 and 0.25‰ (permil) of certified ratios, respectively, and were consistent with literature values within uncertainties. Based on multiple dissolutions with lithium metaborate flux fusion, U and Th concentrations in USGS BCR‐2 CRM were updated to 1739 ± 2 and 5987 ± 50 ng g?1 (95% CI), respectively. The measurement reproducibility of our analytical technique was evaluated by analysing six aliquots of an in‐house reference material, prepared by homogenising a piece of speleothem (CC3A) from Cathedral Cave, Utah, which returned a mean age of 21483 ± 63 years (95% CI, 2.9‰). Replicate analysis of ten samples from CC3A was consistent with ages previously measured at the University of Minnesota by single‐collector ICP‐MS within uncertainties.  相似文献   

19.
The interest in variations of barium (Ba) stable isotope amount ratios in low and high temperature environments has increased over the past several years. Characterisation of Ba isotope ratios of widely available reference materials is now required to validate analytical procedures and to allow comparison of data obtained by different laboratories. We present new Ba isotope amount ratio data for twelve geological reference materials with silicate (AGV‐1, G‐2, BHVO‐1, QLO‐1, BIR‐1, JG‐1a, JB‐1a, JR‐1 and JA‐1), carbonate (IAEA‐CO‐9) and sulfate matrices (IAEA‐SO‐5 and IAEA‐SO‐6) relative to NIST SRM 3104a. In addition, two artificially fractionated in‐house reference materials BaBe12 and BaBe27 (δ137/134Ba = ?1.161 ± 0.049‰ and ?0.616 ± 0.050‰, respectively) are used as quality control solutions for the negative δ‐range. Accuracy of our data was assessed by interlaboratory comparison between the University of Bern and the United States Geological Survey (USGS). Data were measured by MC‐ICP‐MS (Bern) and TIMS (USGS) using two different double spikes for mass bias correction (130Ba–135Ba and 132Ba–136Ba, respectively). MC‐ICP‐MS measurements were further tested for isobaric and non‐spectral matrix effects by a number of common matrix elements. The results are in excellent agreement and suggest data accuracy.  相似文献   

20.
Here, we present determinations of thallium (Tl) concentrations in the USGS reference materials BIR‐1G, BHVO‐2G and BCR‐2G measured by solution ICP‐MS. The Tl content in these three glasses spans a range of about 2–230 ng g?1, which is similar to the values published for the respective powder materials. The determined range of Tl concentrations in these three glass reference materials makes them ideal for investigating Tl concentrations in basaltic and andesitic volcanic glasses. We also performed a series of laser ablation ICP‐MS measurements on the three samples, which show that this technique is able to determine Tl concentrations in glass samples with concentrations as low as 2 ng g?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号