首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
During the past strong ground motions, chimneys constructed according to international standards are representative of similar structures at industrial areas throughout the world, including those collapsed or moderately damaged in earthquake-prone regions. This is due to the specialty of structural characteristics and the special loads acting on the structure such as earthquakes, wind and differences in the level of temperature, etc. In this context, the researchers and designers should focus on the dynamic behavior of chimneys especially under high temperature and seismic effects. For this purpose, the main focus of this study is to evaluate the dynamic response of a chimney under the above-mentioned effects considering soil-structure interaction (SSI). A 52 m steel chimney in Yeşilyurt township of Samsun City in Turkey was studied. The in-situ model testing and numerical models were compared. Before the commissioning of the chimney, a series of tests was realized to define its dynamic characteristics in case of no-heat and after the fabric got to work, the same tests were repeated for the same sensor locations to understand the heat effect on the dynamic response of the chimney. The ambient vibration tests are proven to be fast and practical procedures to identify the dynamic characteristics of those structures. The dynamic testing of the towers promises a widespread use, as the identification of seismic vulnerability of such structures becomes increasingly important. The data presented in this study are considered to be useful for the researchers and engineers, for whom the temperature and SSI effects on steel chimneys are a concern. Using the modal analysis techniques, presented finite element simulation for the soil/pile foundation-chimney interaction system is verified. The results of modal analyses using numerical solutions are shown to have acceptable accuracy compared with results obtained by in-situ test. The present study also aims to provide designers with material examples about the influence of these on the seismic performance of steel chimneys by means of reflecting the changes in the dynamic behavior.  相似文献   

2.
On March 1993 an earthquake of magnitude Ms = 5·5 shook Pyrgos, a town in Western Peloponnissos, one of the most seismic prone areas in Greece. The damage induced to modern reinforced concrete buildings was rather light in contrast to the damage induced to historic and traditional buildings of adobe, stone or brick masonry which was severe. In order to study the causes of structural damage, detailed data are collected from a rather large statistical sample of 1023 masonry buildings and 22 reinforced concrete framed buildings with visible damage. For each building the number of storeys, the material of construction, as well as the type and the degree of damage are recorded. In addition, consideration is given to the site of the building within the town and the corresponding soil conditions. For reinforced concrete buildings, damage occured mostly in areas with relatively high estimated spectral accelerations and fundamental soil periods of vibration close to those of the buildings. Nevertheless, further analysis is required to explain the selective damage of a very small number of buildings. For masonry houses, the effect of soil conditions is more systematic. Moreover, the effects of the number of storeys as well as the age and material of construction appear to be dominant.  相似文献   

3.
We study the nature of energy bursts that appeared in the frequency range 3–5 Hz in ambient seismic noise recorded in the Grenoble basin (French Alps) during a seismological array experiment. A close agreement is found between the identified azimuths of such noise bursts with the location of an industrial chimney. In-situ measurements of the chimney dynamic characteristics show a coincidence between the frequency of the first harmonic mode of the chimney and the fundamental frequency of a thin surficial layer that overlay the deep sediment fill. The interaction between the chimney and the surficial layer is then numerically simulated using simple impedance models and two soil profiles. Simulations exhibit a satisfactory agreement with observations and suggest that energy bursts result of inertial structure-soil interaction favored by resonance effects between the first harmonic mode of the structure and the fundamental frequency of the topmost layer.  相似文献   

4.
This paper focuses on analyzing the nonlinear seismic response of high‐arch dams with cantilever reinforcement strengthening. A modified embedded‐steel model is presented to evaluate the effects of the strengthening measure on alleviating the extension and opening of cracks under strong earthquakes. By stiffening reinforced steel, this model can easily consider the steel–concrete interaction for lightly reinforced concrete (RC) members without the need of dividing them into RC and plain concrete zones. The new tensile constitutive relations of reinforced steel are derived from the load–deformation relationship of RC members in direct tension. This model has been implemented in the finite element code and its applicability is verified by two numerical simulations for RC tests. Subsequently, numerical analyses for a 210‐m high‐arch dam (Dagangshan arch dam) are conducted with and without the presence of cantilever reinforcement. Numerical results show that reinforcement strengthening can reduce the nonlinear response of the arch dam, e.g. joint opening and crest displacement, and limit the extension and opening width of concrete cracks. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
As the Iranian seismic code does not address the soil–structure interaction (SSI) explicitly, the effects of SSI on RC-MRFs are studied using the direct method. Four types of structures on three types of soils, with and without the soil interaction, are modeled and subjected to different earthquake records. The results led to a criterion indicating that considering SSI in seismic design, for buildings higher than three and seven stories on soil with Vs<175 m/s and 175<Vs<375 m/s, respectively, is essential. A simplified procedure has been presented, on the basis that lateral displacement increments could be applied to the fixed-base models using simple factors.  相似文献   

6.
钢管混凝土边框高强混凝土组合剪力墙抗震性能试验研究   总被引:6,自引:1,他引:5  
钢管混凝土边框组合剪力墙是一种新型组合剪力墙。本文进行了2个1/4缩尺的高强混凝土剪力墙模型的低周反复荷载试验,模型1为普通钢筋混凝土剪力墙,模型2为钢管混凝土边框组合剪力墙。在试验研究基础上,对比分析它们的承载力、延性、刚度及其衰减过程、滞回特性、耗能能力及破坏特征,建立了组合剪力墙的承载力计算模型,计算结果与实测结果符合较好。研究表明,钢管混凝土边框高强混凝土组合剪力墙与普通剪力墙相比抗震性能显著提高。  相似文献   

7.
This study aims to realistically simulate the seismic responses of typical highway bridges in California with considerations of soil–structure interaction effects. The p‐y modeling approaches are developed and validated for embankments and pile foundations of bridges. The p‐y approach models the lateral and vertical foundation flexibility with distributed p‐y springs and associated t‐z and q‐z springs. Building upon the existing p‐y models for pile foundations, the study develops the nonlinear p‐y springs for embankments based on nonlinear 2D and 3D continuum finite element analysis under passive loading condition along both longitudinal and transverse directions. Closed‐form expressions are developed for two key parameters, the ultimate resistant force pult and the displacement y50, where 0.5pult is reached, of embankment p‐y models as functions of abutment geometry (wall width and height, embankment fill height, etc.) and soil material properties (wall‐soil friction angle, soil friction angle, and cohesion). In order to account for the kinematic and site responses, depth‐varying ground motions are derived and applied at the free‐end of p‐y springs, which reflects the amplified embankment crest motion. The modeling approach is applied to simulate the seismic responses of the Painter Street Bridge and validated through comparisons with the recorded responses during the 1992 Petrolia earthquake. It is demonstrated that the flexibility and motion amplification at end abutments are the most crucial modeling aspects. The developed p‐y models and the modeling approach can effectively predict the seismic responses of highway bridges. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
The design provisions of current seismic codes are generally not very accurate for assessing effects of near-fault ground motions on reinforced concrete(r.c.)spatial frames,because only far-fault ground motions are considered in the seismic codes.Strong near-fault earthquakes are characterized by long-duration(horizontal)pulses and high values of the ratio α_(PGA)of the peak value of the vertical acceleration,PGA_V,to the analogous value of the horizontal acceleration,PGA_H,which can become critical for girders and columns.In this work,six- and twelve-storey r.c.spatial frames are designed according to the provisions of the Italian seismic code,considering the horizontal seismic loads acting(besides the gravity loads)alone or in combination with the vertical ones.The nonlinear seismic analysis of the test structures is performed using a step-by-step procedure based on a two-parameter implicit integration scheme and an initial stress-like iterative procedure.A lumped plasticity model based on the Haar-Karman principle is adopted to model the inelastic behaviour of the frame members.For the numerical investigation,five near-fault ground motions with high values of the acceleration ratio α_(PGA) are considered.Moreover,following recent seismological studies,which allow the extraction of the largest(horizontal) pulse from a near-fault ground motion,five pulse-type(horizontal)ground motions are selected by comparing the original ground motion with the residual motion after the pulse has been extracted.The results of the nonlinear dynamic analysis carried out on the test structures highlighted that horizontal and vertical components of near-fault ground motions may require additional consideration in the seismic codes.  相似文献   

9.
Various methodologies and modelling criteria for analysing seismically reinforced concrete chimneys are now available. All require consideration of the soil-structure interaction (SSI) effects especially in designing tall chimneys. This becomes more critical when the soil deposit, on which the chimney is founded, is softer. Two examples are considered in this paper: a chimney of moderate height (110 meters) founded directly on a sedimentary rock layered half-space and another very tall chimney (230 meters), founded by means of short prefabricated piles on a deep, very soft, sand deposit. The method of analysis used is a conventional response spectrum modal analysis of a chimney lumped mass model, which includes shear deformation of the chimney shaft. To ignore this effect can lead to an underestimation of the shear force at chimney base level. The suggestions of the specification ACI STANDARD 307-88 are also considered. Different hypotheses to account for the SSI effects are assumed in the analyses which provide a set of conclusions of interest to the point of view of the designer.  相似文献   

10.
To highlight the importance of small earthquakes in seismic hazard, a study of the 11 May 2016, M_w 4.9, Tesistan, Mexico earthquake is presented. Due to the close proximity of the event to the city, accelerations were considerably higher than those caused by historical severe earthquakes(6.0 M_w 8.2). This paper addresses two objectives related to the Tesistan event: the first is to estimate the focal mechanism solution in order to place the event in the context of the tectonic environment of this area. The second is focused on a vulnerability evaluation of buildings that suffered resonance. Several building′s typologies with variations in construction system and height are assessed in terms of resonance with the structural and soil periods. The results show that around the Zapopan station, strong damage is expected in intermediate to high-rise buildings(12-30 m) with moment resistant frame systems and in reinforced concrete shear walls. Masonry structures around this station may not present resonance. In contrast, in the surroundings of the Guadalajara station, all intermediate height buildings from 9 to 21 m may present resonance.  相似文献   

11.
高轴压比下钢管混凝土边框组合剪力墙抗震性能试验研究   总被引:8,自引:1,他引:7  
钢管混凝土边框组合剪力墙是一种适用于高层及超高层建筑的新型组合剪力墙。轴压比是影响剪力墙抗震性能的一个主要因素,高层建筑底部轴压比较大。本文进行了1/4缩尺的1个普通钢筋混凝土剪力墙模型和1个钢管混凝土边框组合剪力墙模型在高轴压比下的低周反复荷载试验。在试验研究基础上,对比分析了剪力墙的承载力、延性、刚度及其衰减过程、滞回特性、耗能能力及破坏特征,建立了钢管混凝土边框组合剪力墙的承载力计算模型,计算结果与实测结果符合较好。研究表明:在高轴压比下钢管混凝土边框组合剪力墙与普通剪力墙相比抗震性能显著提高。  相似文献   

12.
In this paper the effects of deep excavation on seismic vulnerability of existing buildings are investigated. It is well known that deep excavations induce significant changes both in stress and strain fields of the soil around them, causing a displacement field which can modify both the static and dynamic responses of existing buildings. A FEM model of a real case study, which takes into account geometry, non-linear soil behavior, live and dead loads, boundary conditions and soil–structure interaction, has been developed in order to estimate the soil displacements and their effects on seismic behavior of a reinforced concrete framed system close to deep excavation. Considering a significant accelerometric seismic input, the non-linear dynamic responses of the reinforced concrete framed structure, both in the pre and post-excavation configurations, have been evaluated and, then, compared to estimate the modification in seismic vulnerability, by means of different seismic damage indices and inter-story drifts.  相似文献   

13.
应变率对钢筋混凝土剪力墙动态性能的影响   总被引:1,自引:0,他引:1  
张皓  李宏男 《地震学刊》2010,(3):303-308
采用有限元软件ABAQUS中的显示动力分析模块ABAQUS/Explicit,分别对钢筋混凝土剪力墙准静态和高应变率动力荷载作用下的响应进行了数值模拟;通过比较高应变率与准静态加载下的分析结果,探讨了地震作用下应变率对钢筋混凝土剪力墙动态性能的影响。研究结果表明,受应变率效应的影响,混凝土和钢筋的动态力学行为发生了变化,动力荷载作用下的钢筋混凝土剪力墙的承载能力有一定程度的提高,故在对钢筋混凝土结构进行抗震分析时,应适当考虑应变率效应。  相似文献   

14.
The use of relaxation mechanisms has recently made it possible to simulate viscoelastic (Q) effects accurately in time-domain numerical computations of seismic responses. As a result, seismograms may now be synthesized for models with arbitrary spatial variations in compressional- and shear-wave quality factors (Q9, and Qs, as well as in density (ρ) and compressional- and shear-wave velocities (Vp, and Vs). Reflections produced by Q contrasts alone may have amplitudes as large as those produced by velocity contrasts. Q effects, including their interaction with Vp, Vs and p, contribute significantly to the seismic response of reservoirs. For band-limited data at typical seismic frequencies, the effects of Q on reflectivity and attenuation are more visible than those on dispersion. Synthetic examples include practical applications to reservoir exploration, evaluation and monitoring. Q effects are clearly visible in both surface and offset vertical seismic profile data. Thus, AVO analyses that neglect Q may produce erroneous conclusions.  相似文献   

15.
型钢高强混凝土柱抗震性能的试验研究   总被引:5,自引:3,他引:5  
通过14根型钢高强混凝土柱的低周反复加载试验,得到了型钢高强混凝土柱在压、弯、剪共同作用下的主要破坏形态,并探讨了剪跨比、配箍率、混凝土强度对型钢高强混凝土柱滞回曲线、耗能能力以及延性的影响。试验结果表明,型钢高强混凝土柱具有抵御二次地震作用的能力,其抗震性能优于钢筋混凝土柱。  相似文献   

16.
型钢混凝土剪力墙的抗震性能研究   总被引:1,自引:1,他引:1  
型钢混凝土剪力墙(亦称为SRC剪力墙)是一种新型的剪力墙,其抗弯承载力、抗剪承载力及延性均好于普通剪力墙。本文简要总结了近年来国内外关于型钢混凝土剪力墙抗震研究的成果。在此基础上,进行了较高轴压比下内藏钢桁架混凝土组合高剪力墙的抗震性能试验研究。试验研究表明,内藏钢桁架的存在明显改善了高轴压比下型钢混凝土高剪力墙的抗震性能。  相似文献   

17.
Experimental proof is provided of an unconventional seismic design concept, which is based on deliberately underdesigning shallow foundations to promote intense rocking oscillations and thereby to dramatically improve the seismic resilience of structures. Termed rocking isolation, this new seismic design philosophy is investigated through a series of dynamic centrifuge experiments on properly scaled models of a modern reinforced concrete (RC) bridge pier. The experimental method reproduces the nonlinear and inelastic response of both the soil‐footing interface and the structure. To this end, a novel scale model RC (1:50 scale) that simulates reasonably well the elastic response and the failure of prototype RC elements is utilized, along with realistic representation of the soil behavior in a geotechnical centrifuge. A variety of seismic ground motions are considered as excitations. They result in consistent demonstrably beneficial performance of the rocking‐isolated pier in comparison with the one designed conventionally. Seismic demand is reduced in terms of both inertial load and deck drift. Furthermore, foundation uplifting has a self‐centering potential, whereas soil yielding is shown to provide a particularly effective energy dissipation mechanism, exhibiting significant resistance to cumulative damage. Thanks to such mechanisms, the rocking pier survived, with no signs of structural distress, a deleterious sequence of seismic motions that caused collapse of the conventionally designed pier. © 2014 The Authors Earthquake Engineering & Structural Dynamics Published by John Wiley & Sons Ltd.  相似文献   

18.
The aim of this paper is to adjust behaviour models for each class of structure for vulnerability assessment by using ambient vibration. A simple model based on frequencies, mode shapes and damping, taken from ambient vibrations, allows computation of the response of the structures and comparison of inter‐storey drifts with the limits found in the literature for the slight damage grade, considered here as the limit of elastic behaviour. Two complete methodologies for building fragility curves are proposed: (1) using a multi‐degree of freedom system including higher modes and full seismic ground‐motion and (2) using a single‐degree of freedom model considering the fundamental mode f0 of the structure and ground‐motion displacement response spectra SD(f0). These two methods were applied to the city of Grenoble, where 60 buildings were studied. Fragility curves for slight damage were derived for the various masonry and reinforced concrete classes of buildings. A site‐specific earthquake scenario, taking into account local site conditions, was considered, corresponding to an ML = 5.5 earthquake at a distance of 15 km. The results show the benefits of using experimental models to reduce variability of the slight damage fragility curve. Moreover, by introducing the experimental modal model of the buildings, it is possible to improve seismic risk assessment at an overall scale (the city) or a local scale (the building) for the first damage grade (slight damage). This level of damage, of great interest for moderate seismic‐prone regions, may contribute to the seismic loss assessment. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
An investigation on the validity of the conventional design approach known as constant displacement ductility is carried out. The hysteretic behaviour described by the Modified Takeda model is taken to represent the characteristics of reinforced concrete structural systems. The results presented in the form of seismic damage spectra indicate that the conventional design approach may not be valid because cumulative damage is excessively high. The inelastic design spectra based on the constant‐damage concept are proposed in terms of simplified expressions. The expressions are derived from constant‐damage design spectra computed by non‐linear response analysis for SDOF systems subjected to ground motions recorded on rock sites, alluvium deposits, and soft‐soil sites. The proposed expressions, which are dependent on the local soil conditions, are functions of target seismic damage, displacement ductility ratio and period of vibration. The seismic damage of structures that have been designed based on this new design approach is also checked by a design‐and‐evaluation approach. The results are found to be satisfactory. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

20.
An experimental investigation on the seismic behavior of a type of outrigger truss-reinforced concrete wall shear connection using multiple steel angles is presented. Six large-scale shear connection models, which involved a portion of reinforced concrete wall and a shear tab welded onto a steel endplate with three steel angles, were constructed and tested under combined actions of cyclic axial load and eccentric shear. The effects of embedment lengths of steel angles, wall boundary elements, types of anchor plates, and thicknesses of endplates were investigated. The test results indicate that properly detailed connections exhibit desirable seismic behavior and fail due to the ductile fracture of steel angles. Wall boundary elements provide beneficial confinement to the concrete surrounding steel angles and thus increase the strength and stiffness of connections. Connections using whole anchor plates are prone to suffer concrete pry-out failure while connections with thin endplates have a relatively low strength and fail due to large inelastic deformations of the endplates. The current design equations proposed by Chinese Standard 04G362 and Code GB50011 significantly underestimate the capacities of the connection models. A revised design method to account for the influence of previously mentioned test parameters was developed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号