首页 | 官方网站   微博 | 高级检索  
     

不同注射速率下多层螺旋CT直接法下肢静脉成像髂静脉图像质量的比较
引用本文:李高阳,张丹,吕亮,邢媛媛,王宁,常英伟.不同注射速率下多层螺旋CT直接法下肢静脉成像髂静脉图像质量的比较[J].CT理论与应用研究,2018,27(3):401-409.
作者姓名:李高阳  张丹  吕亮  邢媛媛  王宁  常英伟
作者单位:1. 承德医学院附属医院放射科, 河北 承德 067000;
摘    要:目的:探究不同造影剂注射速率对多层螺旋CT直接法髂静脉成像质量的影响,以寻求最佳的注射速率。资料与方法:我们于2015年9月至2017年1月间将怀疑有髂静脉疾病的患者150例随机分为5组,并分别以注射速率为1.5 mL/s、2.0 mL/s、2.5 mL/s、3.0 mL/s、3.5 mL/s进行髂静脉CT成像。原始数据经过CT图像后处理后对每例血管显影质量进行评分,从图像的显影质量、对比度、有无"边流现象"及能否对疾病做出正确诊断进行评价。测量各评分组内髂外静脉的CT值并计算均值,对各评分组的结果进行统计学分析。结果:速率为2.5 mL/s组与3.0 mL/s组比较,差异无统计学意义;而2.5 mL/s组及3.0 mL/s组分别与其余三组进行两两比较时,差异均有统计学意义;1.5 mL/s组、2.0 mL/s组及3.5 mL/s组进行两两比较,调整显著性均大于0.05,差异无统计学意义。各评分组内髂静脉的CT值均数方差分析结果P<0.05,1-2、1-3、1-4、2-3、2-4、3-4各对比组次结果q值分别为4.89、4.94、5.30、4.35、5.02、4.67。P均<0.05,差异有统计学意义。髂静脉的CT值与各评分组的相关系数r值为0.87,P<0.05。结论:综合考虑图像质量、患者的耐受性及人身安全等因素,速率为2.5 mL/s是多层螺旋CT直接法髂静脉成像的最佳速率。 

关 键 词:髂静脉    体层摄影术    X线计算机    血管造影术    下肢
收稿时间:2018-01-19

Comparison of Image Quality of Iliac Vein in Lower Extremity Vein Direct Imaging by Multi-slice Spiral CT with Different Injection Rates
LI Gao-yang,ZHANG Dan,LV Liang,XING Yuan-yuan,WANG Ning,CHANG Ying-wei.Comparison of Image Quality of Iliac Vein in Lower Extremity Vein Direct Imaging by Multi-slice Spiral CT with Different Injection Rates[J].Computerized Tomography Theory and Applications,2018,27(3):401-409.
Authors:LI Gao-yang  ZHANG Dan  LV Liang  XING Yuan-yuan  WANG Ning  CHANG Ying-wei
Affiliation:1. Department of Radiology, Affiliated Hospital of Chengde Medical College, Chengde 067000, China;2. Chengde Nursing Vocational College, Chengde 067000, China
Abstract:Objective: To investigate the effect of different contrast media injection rates on the imaging quality of multi-slice spiral CT direct iliac vein imaging in order to find the optimal injection rate. Materials and Methods: Between September 2015 and January 2017, 150 patients with suspected iliac vein disease were randomly divided into 5 groups. And the iliac vein CT imaging was performed at the injection rate of 1.5 mL/s, 2 mL/s, 2.5 mL/s, 3 mL/s and 3.5 mL/s respectively. The original data were graded after CT image post-treatment for each patient. From the image development quality, contrast, with or without "edge flow phenomenon" and whether the disease can make the correct diagnosis of four aspects of the evaluation. The CT values of the external iliac vein in each scoring group were measured and the mean value was calculated. The results of each evaluation group were statistically analyzed. Results: The rate of 2.5 mL/s group and 3.0 mL/s group, the difference was not statistically significant, but compared with the other three groups, the difference was statistically significant; 1.5 mL/s group, 2.0 mL/s group and 3.5 mL/s were compared, the signiftcance of adjustment was greater than 0.05, the difference was not statistically significant. The mean CT values of iliac vein in each evaluation group were analyzed by variance analysis P<0.05, 1-2, 1-3, 1-4, 2-3, 2, 4, 3, 4 The results of the comparison group were 4.89, 4.94, 5.30, 4.35, 5.02, 4.67 respectively. P were <0.05, the difference was statistically significant. The correlation coefficient between the CT value of the iliac vein and the score group was 0.87, P<0.05. Conclusion Considering the image quality, patient's tolerance and personal safety and other factors, the rate of 2.5 mL/s is the best rate of multi-slice spiral CT direct iliac vein imaging. 
Keywords:
本文献已被 万方数据 等数据库收录!
点击此处可从《CT理论与应用研究》浏览原始摘要信息
点击此处可从《CT理论与应用研究》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号